Preferred Language
Articles
/
bsj-848
Influence of Laser Irradiation Times on Properties of Porous Silicon
...Show More Authors

Porous silicon (P-Si) has been produced in this work by photoelectrochemical (PEC) etching process. The irradiation has been achieved using diode laser of (2 W) power and 810 nm wavelength. The influence of various irradiation times on the properties of P-Si material such as P-Si layer thickness, surface aspect, pore diameter and the thickness of walls between pores as well as porosity and etching rate was investigated by depending on the scanning electron micrograph (SEM) technique and gravimetric measurements.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue May 23 2023
Journal Name
Journal Of Engineering
Injection Temperature Effects on the Properties of High Density Polyethylene Crates
...Show More Authors

This study was undertaken to provide more insight on the optimum injection temperature used for the production of PE crates, thereby saving time and money, and improving part quality. The work included processing trails of HDPE crates in an injection
molding machine at five temperatures ranged from 220 to 300°C. Both Rheological and mechanical characterization was conducted in order to understand the effect of injection temperature on the properties of crates. Oven aging was also applied for (4 weeks) to evaluate the long-term thermal stability. The results revealed that producing the crates at a temperature range of (260-280 °C) gives the best rheological and mechanical result. The lowest drop in thermal stability has been observed

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Feb 29 2012
Journal Name
Al-khwarizmi Engineering Journal
Effect of Solid Properties on Axial Liquid Dispersion in Bubble Column
...Show More Authors

Experiments were conducted to study axial liquid dispersion coefficient in slurry bubble column of 0.15 m inside diameter and 1.6 m height using perforated plate gas distributor of 54 holes of a size equal to 1 mm diameter and with a 0.24 free area of holes to the cross sectional area of the column. The three phase system consists of air, water and PVC used as the solid phase. The effect of solid loading (0, 30 and 60 kg/m3) and solid diameter (0.7, 1.5 and 3 mm) on the axial liquid dispersion coefficient at different axial location (25, 50 and 75 cm) and superficial gas velocity covered homogeneous-heterogeneous flow regime (1-10 cm/s) were studied in the present work. The results show that the axial liquid dispersion coeffic

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 03 2009
Journal Name
Engineering And Technology Journal
Study on the properties of composite materials produced by centrifugal casting
...Show More Authors

سمير خلف فياض * و محسن طالب د.نوال عزت عبد اللطيف*, مجلة الهندسة والتكنولوجيا, 2010

View Publication Preview PDF
Publication Date
Wed Jan 10 2024
Journal Name
Journal Of Optics
Pulsed laser deposition of Pd/WO3 nanoparticles on Si nanostructure for highly sensitive room-temperature gas sensors
...Show More Authors

View Publication
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sun Oct 15 2023
Journal Name
Bionatura
Study the effect of the different doses from the laser on Staphylococcus aureus Bacteria growth in vitro
...Show More Authors

Background: Laser is a novel physical therapy technique used to treat various conditions, including wound healing, inhibition of bacterial growth, and postoperative wounds. High-power pulsed alexandrite laser therapy is one of the most prevalent forms of laser therapy, which is a noninvasive method for treating various pathological conditions, thereby enhancing functional capacities and quality of life. It is a modern medical and physiotherapeutic technology. Generally, the Alexandrite laser emits infrared light with a wavelength of 755 nm, allowing it to propagate and penetrate tissues. Objective: This study focused on the application of a high-power pulsed alexandrite laser in vitro to evaluate the effect of a pulsed alexandrite l

... Show More
View Publication
Crossref (1)
Scopus Crossref
Publication Date
Tue Nov 18 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Remineralizing Toothpastes on Enamel Surface Roughness after Hybrid Laser Bleaching (An In vitro Study)
...Show More Authors

Background: one of the complications of power bleaching is surface roughness of enamel which increases the possibility of post bleaching teeth discoloration. The aim of the present study is to evaluate the effect of toothpaste containing nano hydroxyapatite, NovaMin and kin sense fluoride on surface roughness of human tooth enamel after laser bleaching with 35% hydrogen peroxide bleaching gel. Materials and Methods: Twenty human enamel incisors were cleaned and their labial surface polished up to #1200, then categorized into four equal groups; first group kept without bleaching as a control group, while the remaining three experimental groups were bleached with 35% hydrogen peroxide, and each group treated with a restore paste containing o

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 06 2015
Journal Name
Baghdad Science Journal
The Bactericidal Effect of CO2 Laser on Pseudomonas aeruginosa Isolated from Wound and Burn Infections, In-Vitro
...Show More Authors

A total of 60 cotton swabs are collected from patients suffering from burn wound and surgical site infections admitted to Baghdad Teaching Hospital and Burn Specialist Hospital in Baghdad city during 9/2013 to 11/2013. All cotton swabs are cultured initially on blood agar and MacConkey agar and subjected for standard bacteriological procedures for bacteriological diagnosis. Twenty samples out of sixty are identified as Pseudomonas aeruginosa by conventional methods. The results of antibiotic susceptibility test illustrate that the antibiotics resistance rate of Pseudomonas aeruginosa isolates is as follows:100% (2020) for ceftriaxone, cefepime and carbencillin, 70% (14/20) for amikacin, 65%(13/20) for tobramycin, ceftazidim and gentamycin,

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Oct 17 2018
Journal Name
Iraqi Journal Of Laser
Thermal Effects of 940 nm Diode Laser on Dental Socket Blood after Teeth Extraction for Diabetic Patients
...Show More Authors

Abstract: Background: High percentage of diabetes patients complain from post extraction hemorrhage. Many types of hemostatic materials are used to stop bleeding after teeth extraction: diode lasers are good hemostatic agents owing to their highly absorption by hemoglobin therefore they are used in soft tissue procedures with relatively no effects on dental hard tissues due to their poorly absorption by water and hydroxyapatite. Objectives: The aim of this study is to evaluate the efficiency of diode laser to assist the clot formation after tooth extraction for type II diabetes patients with minimum temperature elevation to prevent periodontal destruction. Materials and methods: From 12 type II diabetes patients (7 males and 5 females wi

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
Baghdad Science Journal
Effect of SnO2/In2O3 Atomic Ratio on the Structural and Optical Properties of ITO Thin Filmsof SnO2:In2O3 Thin Film Composite Ratio on Structural and Optical Properties
...Show More Authors

In this work, the effect of atomic ratio on structural and optical properties of SnO2/In2O3 thin films prepared by pulsed laser deposition technique under vacuum and annealed at 573K in air has been studied.  Atomic ratios from 0 to 100% have been used. X-ray diffraction analysis has been utilized to study the effect of atomic ratios on the phase change using XRD analyzer and the crystalline size and the lattice strain using Williamson-Hall relationship. It has been found that the ratio of 50% has the lowest crystallite size, which corresponds to the highest strain in the lattice. The energy gap has increased as the atomic ratio of indium oxide increased.

View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Wed Sep 16 2020
Journal Name
F1000research
Green tea influence on iron overload in thalassemia intermedia patients: a randomized controlled trial
...Show More Authors

Background: Although iron chelation therapies have been available for many years for thalassemia intermedia patients, iron accumulation remains the major cause of death. Therefore, the need for additional chelation options is in demand. This randomized controlled study aimed to understand the effects of green tea on iron balance in thalassemia intermedia patients.

Methods: Using a random selection method, 141 thalassemia intermedia patients were initially screened for inclusion in this trial; only 68 patients included after applying exclusion criteria. Two equal groups were generated (n=34/group): green tea (three cups/day after meals) + usual treatment (deferasirox iron chelat

... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Crossref