Preferred Language
Articles
/
bsj-8362
AlexNet Convolutional Neural Network Architecture with Cosine and Hamming Similarity/Distance Measures for Fingerprint Biometric Matching
...Show More Authors

In information security, fingerprint verification is one of the most common recent approaches for verifying human identity through a distinctive pattern. The verification process works by comparing a pair of fingerprint templates and identifying the similarity/matching among them. Several research studies have utilized different techniques for the matching process such as fuzzy vault and image filtering approaches. Yet, these approaches are still suffering from the imprecise articulation of the biometrics’ interesting patterns. The emergence of deep learning architectures such as the Convolutional Neural Network (CNN) has been extensively used for image processing and object detection tasks and showed an outstanding performance compared to traditional image filtering techniques. This paper aimed to utilize a specific CNN architecture known as AlexNet for the fingerprint-matching task. Using such an architecture, this study has extracted the significant features of the fingerprint image, generated a key based on such a biometric feature of the image, and stored it in a reference database. Then, using Cosine similarity and Hamming Distance measures, the testing fingerprints have been matched with a reference. Using the FVC2002 database, the proposed method showed a False Acceptance Rate (FAR) of 2.09% and a False Rejection Rate (FRR) of 2.81%. Comparing these results against other studies that utilized traditional approaches such as the Fuzzy Vault has demonstrated the efficacy of CNN in terms of fingerprint matching. It is also emphasizing the usefulness of using Cosine similarity and Hamming Distance in terms of matching.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Mar 01 2013
Journal Name
Applied Mechanics And Materials
Measure and Analyze the Problems of Concrete Mixture Production via Six Sigma DMAIC Tools: Central Concrete Mix Plant as a Case Study
...Show More Authors

The aims of this study are to measure the defect rate and analyze the problems of production of ready concrete mixture plant by using Six Sigma methodology which is a business strategy for operations improvement depending basically on the application of its sub-methodology DMAIC improvement cycle and the basic statistical tools where the process sigma level of concrete production in the case study was 2.41 σ.

View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sat May 23 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Thickness of Buccal Bone at Various Sites of the Mandible and Its Clinical Significance in MonocorticalScrews Placement Using Multi-Slice Computed Tomography
...Show More Authors

Background:Open reduction and internal fixation (ORIF) of using miniplates and screws is the treatment of choice of mandibular fractures. It is important to know both: the region where the bone providesafirm anchorage, andthe topography of the dental apices and inferior alveolar nerve to avoiddamaging them when inserting the screw. The aim of this study is to determine the thickness of buccal cortical plate and that of buccal bone at the parasymphysis and mandibular body, thereby determining the area that provide afirm anchorage and the maximum length of mono-cortical screws that can be safely placed in these regions without injuring the tooth roots or mandibular nerve. Materials and Methods:The sample of the present study was 110 Iraqi sub

... Show More
View Publication Preview PDF
Publication Date
Sat May 23 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Acidity Level on Ions Released and Corrosion of Metal Orthodontic Appliances at Different Time Intervals (An In vitro Study)
...Show More Authors

ABSTRACT Background: This study measured the effects of three parameters pH value, length of immersion and type of archwire on metal ions released from orthodontic appliances. Materials and Methods: Ninety maxillary halves simulated fixed orthodontic appliances that were immersed in artificial saliva of different pH values (6.75, 5 and 3.5) during 28 day period. Three types of archwires were used: stainless steel, nickel titanium and thermal activated nickel titanium. The quantity of nickel and chromium ions was determined with the use of atomic force spectrophotometer while iron ions by spectrophotometer. Each orthodontic set was weighted two times, before the ligation and immersion in the artificial saliva and after 28 days at the end of

... Show More
View Publication Preview PDF
Publication Date
Sat May 23 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Validity of computed tomographic in assessment of genial tubercle and anterior mandible as a reference guide to locate osteotomy in genioglossus advancement
...Show More Authors

Background: Genioglossus advancement is a surgical procedure to advance the tongue in some patients with obstructive sleep apnea syndrome.The important step in this procedure is that of accurately capturing the bone segment attached to the genioglossus muscle to avoid complications such as mandibular fracture, devitalization of the inferior incisor roots, and incomplete incorporation of the genioglossus Materials and Method: Computed tomography scans were taken for 53 Iraqi adult patients (28 male and 25 female) range from (18-35) years with skeletal class I classification and intact anterior mandible dentition included in this study using sagittal and axial sections. The measurements were done for genial tubercle and anterior mandibular re

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 23 2024
Journal Name
European Journal Of Orthodontics
Poly-Ether-Ether-Ketone versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 2: periodontal health and microbial biofilm assessment
...Show More Authors
Abstract<sec> <title>Background

Retainers have the potential to detrimentally impact periodontal health and contribute to tooth decay.

Objectives

To investigate periodontal health and bacterial biofilm related to Poly-Ether-Ether-Ketone (PEEK) fixed retainers as compared to Dead-soft coaxial fixed retainer (DSC).

Trial design

A two-arm parallel groups single-centre randomized c

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Feb 28 2022
Journal Name
Journal Of Educational And Psychological Researches
The Effect of Using the Strategy of Roundhouse in the Achievement of Fourth Grade Students of Computer and Their Attitudes towards It
...Show More Authors

The research aims to identify the effect of using the strategy of Roundhouse on the achievement of fourth-grade students of computer and their Attitudes towards it. The research sample consisted of (61) fourth-grade secondary school students distributed into the experimental group consisted of (31) students study computer according to the Roundhouse strategy, and the control group consisted of (30) students follow the traditional method. The researcher designed an achievement test consisting of (30) items of multiple choice. To measure the attitudes of students towards the computer, a questionnaire of (32) paragraphs with three alternatives was designed by the researcher. The results showed that there is a statistically significant diffe

... Show More
View Publication Preview PDF
Publication Date
Tue Jul 31 2012
Journal Name
Journal Of Babylon University/pure And Applied Sciences/
An Evaluation of the Effect of Bleaching Agent on Microhardness of a New Silorane-Based Restorative System and Methacrylate-Based Restorative Material
...Show More Authors

Abstract Rasha Hameid Jehad Baghdad University Background: The high reactivity of hydrogen peroxide used in bleaching agents have raised important questions on their potential adverse effects on physical properties of restorative materials. The purpose of this in vitro study was to evaluate the effect of in-office bleaching agents on the microhardness of a new Silorane-based restorative material in comparison to methacrylate-based restorative material. Materials and method: Forty specimens of Filtek™ P90 (3M ESPE,USA) and Filtek™ Supreme XT (3M ESPE, USA) of (8mm diameter and 3m height) were prepared. All specimens were polished with Sof-Lex disks (3M ESPE, USA). All samples were rinsed and stored in incubator 37˚C for 24 ho

... Show More
Publication Date
Thu May 12 2022
Journal Name
Journal Of Kerbala For Agricultural Sciences
Response of Bread Wheat Crop to the Spray of Alcoholic Sugars and A balanced Mineral Fertilizer in the Central Region of Iraq
...Show More Authors

Two field experiments were conducted during the season 2021-2022 in central Iraq represented by the Al-Muthanna governorate - Al-Majd District and Al-Qadisiyah governorate / Al-Nouriah Research Station to determine the productivity of the Baghdad 3 cultivar from spray foliar fertilization of Macro and Micro elements with alcoholic sugars and half the fertilizer recommendation for addition floor, three treatments were used for fertilization: T1 as the control treatment and T2 with alcoholic sugar fertilization at a concentration of 20 g.L-1 + the fertilizer combination of Macro and Micro elements, and T3 with alcoholic sugar fertilization at a concentration of 40 g.L-1 + the fertilizer combination of Macro and Microelements, at irrigation 55

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat May 23 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Zirconium Silicate Nanopowder Reinforcement on Some Mechanical and Physical Properties of Heat Cured Poly (Methyl Methacrylate) Denture Base Materials
...Show More Authors

Background: Polymethylmethacrylate (PMMA) has relatively unsatisfactory mechanical properties such as low flexural strength and impact strength also dimensional instability. Material and method: Zirconium silicate nanoparticles were coated with a layer of trimethoxysilylpropylmethacrylate (TMSPM) before sonication in monomer (MMA) with the percentages 1% and 1.5% by weight then mixed with powder using conventional procedure, (150) samples were prepared and divided into three groups, each group consisted of (50) samples, the first group prepared from PMMA without addition (control), another group with the addition of 1% wt Zrsio4 nanoparticles (experimental) and the third one with 1.5% wt Zrsio4 nanoparticles (experimental). Each group

... Show More
View Publication Preview PDF
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Metal Complexes of Multidentate N<sub>2</sub>S<sub>2</sub> Heterocyclic Schiff-base Ligands;Formation, Structural Characterisation and Biological Activity
...Show More Authors
Abstract<p>The synthesis of ligands with N<sub>2</sub>S<sub>2</sub> donor sets that include imine, an amide, thioether, thiolate moieties and their metal complexes were achieved. The new Schiff-base ligands; N-(2-((2,4-diphenyl-3-azabicyclo[3.3.1]nonan-9-ylidene)amino)ethyl)-2-((2-mercaptoethyl)thio)-acetamide (H<sub>2</sub>L<sup>1</sup>) and N-(2-((2,4-di-p-tolyl-3-azabicyclo[3.3.1]nonan-9-ylidene)amino)ethyl)-2-((2-mercaptoethyl)thio) acetamide (H2L<sup>2</sup>) were obtained from the reaction of amine precursors with 1,4-dithian-2-one in the presence of triethylamine as a base in the CHCl3 medium. Complexes of the general formula K<sub>2<</sub></p> ... Show More
View Publication
Scopus (12)
Crossref (4)
Scopus Crossref