Preferred Language
Articles
/
bsj-832
Embryonic Development of Eye Lens in Mosquito fish Gambusia affinis (Baird and Girard, 1853)
...Show More Authors

The embryonic development of the Mosquito fish(Gambusia affinis) eye lens was investigated using light microscopy .The results indicated that the embryonic development of the lens does not correspond to that of the non spherical lenses of terrestrial vertebrates .This study showed that a very small cavity in the lens vesicle appears during development ,but it differs from that of the mammalian lens. The most important aspect in this study is that ,the posterior edge of the simple cuboidal epithelium which covers the anterior half of the surface of the lens is situated well beyond the equatorial region of the lens .As a result , the germinal and transitional zones became closer to the posterior pole rather than the anterior pole of the lens. This might be an important factor in causing the lens to be spherical rather than being biconvex.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 09 2022
Journal Name
American Journal Of Orthopsychiatry
Intersected Discrimination Through the Lens of COVID-19: The Case Example of Christian Minority in Iraq
...Show More Authors

Compelling evidence proved that coronavirus disease (COVID-19) disproportionately affects minorities. The goal of the present study was to explore the effects of intersected discrimination and discrimination types on COVID-19, mental health, and cognition. A sample of 542 Iraqis, 55.7% females, age ranged from 18 to 73, with (M = 31.16, SD = 9.77). 48.7% were Muslims, and 51.3% were Christians (N = 278). We used measures for COVID-19 stressors, executive functions, intersected discrimination (gender discrimination, social groups-based discrimination, sexual orientation discrimination, and genocidal discrimination), posttraumatic stress disorder (PTSD), depression, anxiety, status and death, existential anxieties, and health. We conducted in

... Show More
Preview PDF
Publication Date
Thu Dec 16 2021
Journal Name
Kufa Medical Journal
Clinical and Refractive Outcomes of Toric Phakic Implantable Collamer Lens Implantation for correction of myopic astigmatism
...Show More Authors

Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber. Aim: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. Methods: Sixty eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design) in the Eye Specialty Private Hospital, Baghdad, Iraq were studied. The mean spherical refraction was -11.32±3.17 diopter (D) with a range of -6.00 to -18.00 D and a mean cylinder of -2.61±1.16 with range of -1.00 to -5.50 D. The outcome measures that evaluat

... Show More
View Publication
Crossref
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
Clinical and Refractive Outcomes of Toric Phakic Implantable Collamer lens Implantat for correction of myopic astigmatism
...Show More Authors

Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber.

Objective: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. in  Eye Specialty Private Hospital, Baghdad, Iraq.

Type of the Study: a prospective non randomize intervention study.

Methods: 60 eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design).Mean spherical refraction was ₋11.32 diopter

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
The micronucleated erythrocytes in speeies of Iraqi fish as indieator of dilution
...Show More Authors

The micronucleated erythrocytes in fish was used to detect water pollution by genotoxic agents. Fish belonging to different species were collected from three regions from Baghdad during three months (December/2000,January and February/2001 ).The micronucleated erythrocytes was observed in all the specimens. It was concluded that the genotoxic activity' in one region was less than in die other two regions.?

View Publication Preview PDF
Publication Date
Sun Mar 03 2013
Journal Name
Baghdad Science Journal
The effect of surlactin produced by Lactobacillus acidophilus on eye infectious bacteria in rabbits
...Show More Authors

Twenty five vaginal swabs from outpatients' healthy women were collected from Kamal Al-Samarai Hospital, Baghdad, to isolate and identify of Lactobacillus acidophilus. Three isolates were diagnosed as L. acidophilus which represents 15% of the total number of lactic acid bacterial (LAB) isolates; other LAB types represent 65% (20 isolates).The ability of L. acidophilus to produce surlactin was detected after measuring its biological activity to inhibit the adhesion of biofilm formed by Pseudomonas aeruginosa to surfaces using test tube method. It was found that all isolates were able to produce surlactin but the activity of surlactin was varying in each isolate. Surlactin produced by isolates 1 and 13 was the most effective. Biological appl

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Design of six electrode Enzial electrostatic lens low aberrations for electron gun
...Show More Authors

A computerized investigation has been carried out on the design of six electrodes electrostatic lenses used in electron gun application. The Finite-Element Method (FEM) was used in the solution of Laplace equation for determine the axial potential distribution. The electron trajectory under zero magnification condition. The optical properties, spherical and chromatic aberrations, the object and image focal length and object and image position are calculated. A very good futures for the electron gun with these lenses have been computed where are a beam current of 8.7*10-7A can be supplied using cathode tip of radius 10nm.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Feb 02 2019
Journal Name
Journal Of The College Of Education For Women
Design of an Electron Gun Using two Electrod Low Aberration Immersion Lens
...Show More Authors

Abstract
A two electrode immersion electrostatic lens used in the design
of an electron gun, with small aberration, has been designed using
the finite element method (FEM). By choosing the appropriate
geometrical shape of there electrodes the potential V(r,z) and the
axial potential distribution have been computed using the FEM to
solve Laplace's equation.
The trajectory of the electron beam and the optical properties of
this lens combination of electrodes have been computed under
different magnification conditions (Zero and infinite magnification
conditions) from studying the properties of the designed electron
gun can be supplied with Abeam current of 5.7*10-6 A , electron
gun with half acceptance

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 31 2015
Journal Name
Kerbala Journal Of Pharmaceutical Sciences
Investigation the Factors Affecting on Gatifloxacin Eye Drop Stability
...Show More Authors

This research included the study of different factors that may effect on gatifloxacin stability (anew quinolone synthetic antibacterial agent) in its aqueous solution in order to develop and optimize the best delivary of the drug to the eye (as eye drop) with maximum local concentration and minimum systemic absorption and toxicity.Different formulas of gatifloxacin solution for ophthalmic use (0.3%)w/v were prepared in citrate, acetate,citrate/phosphate and phosphate buffers,their tonicity adjusted with suitable quantity of sodium chloride.The effect of different factors that might affectthe stability of gatifloxacin in its prepared ophthalmic solution was studied and determined spectrophotometrically at 287 nm. The results showed t

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 28 2020
Journal Name
The Iraqi Journal Of Veterinary Medicine
Isolation and Molecular Identification of Nontuberculous Mycobacterium from Different Species of Fish in Karbala Province, Iraq
...Show More Authors

This study was designed for isolation and molecular identification of Nontuberculous Mycobacterium (NTM) from fish during the period between October and December 2017 from Karbla province, Iraq. This study included 200 fresh fish samples from four different species including Spondyliosoma cantharus, Liza abu, Carassius carassius and Cyprinuscarpio. Three samples of each fish were taken including gills, muscles and all internal organs. The samples were processed by decontamination, concentration of 4% sodium hydroxide, and 0.1 ml of sediment was streaking on Löwenstein Johnson (LJ) media; then the bacterial cultures were incubated at 28-30 °C for 3days up to 4 weeks and suspected colonies were stained with acid fast stain to confir

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Tue Jan 28 2014
Journal Name
Toxins
Co-occurrence of the Cyanotoxins BMAA, DABA and Anatoxin-a in Nebraska Reservoirs, Fish, and Aquatic Plants
...Show More Authors

View Publication
Scopus (116)
Crossref (115)
Scopus Clarivate Crossref