Examining and comparing the image quality of degenerative cervical spine diseases through the application of three MRI sequences; the Two-Dimension T2 Weighed Turbo Spin Echo (2D T2W TSE), the Three-Dimension T2 Weighted Turbo Spin Echo (3D T2W TSE), and the T2 Turbo Field Echo (T2_TFE). Thirty-three patients who were diagnosed as having degenerative cervical spine diseases were involved in this study. Their age range was 40-60 years old. The images were produced via a 1.5 Tesla MRI device using (2D T2W TSE, 3D T2W TSE, and T2_TFE) sequences in the sagittal plane. The image quality was examined by objective and subjective assessments. The MRI image characteristics of the cervical spines (C4-C5, C5-C6, C6-C7) showed significant differences among the three sequences used P˂0.05 with the exception of the contrast P˃ 0.05. For the cervical spines (C4-C5), the minimum CNR was noticed with the T2_TFE sequence. For the cervical spines (C5-C6), the CNR and SNR were higher when they were assessed by the 2D T2W TSE sequence as compared to the other sequences. The same findings were observed with the cervical spines (C6-C7). The subjective assessment of the degenerative cervical spine diseases showed that the T2_TFE sequence is excellent in terms of viewing the central stenosis and foraminal stenosis. The best MRI diagnostic imaging can be obtained using the Turbo Field Echo (T2_TFE) and the Three-Dimension T2 Weighted Turbo Spin Echo (3D T2W TSE) sequences to gain detailed diagnostic information regarding the central stenosis and foraminal stenosis of the cervical spines (C4-C5, C5-C6, C6-C7)
Abstract This research scrutinizes the impact of external magnetic field strength variations on plasma jet parameters to enhance its performance and flexibility. Plasma jets are widely used for their high thermal and kinetic energy in both medical and industrial fields. The study employs optical emission spectroscopy to measure electron temperature, electron density, and plasma frequency in a plasma jet subjected to varying magnetic field strengths (25, 50, 100, 150, and 250 mT). The results indicate that a stronger magnetic field results in higher electron temperature (1.485 to 1.991 eV), electron density (5.405 × 1017 to 7.095 × 1017), and plasma frequency 7.382 × 1012 to 8.253 × 1012 Hz. As well as the research investigates the influ
... Show MoreBackground: Determination of sex and estimation of stature from the skeleton is vital to medicolegal investigations. Skull is composed of hard tissue and is the best preserved part of skeleton after death, hence, in many cases it is the only available part for forensic examination. Lateral cephalogram is ideal for the skull examination as it gives details of various anatomical points in a single radiograph. This study was undertaken to evaluate the accuracy of digital cephalometric system as quick, easy and reproducible supplement tool in sex determination in Iraqi samples in different age range using certain linear and angular craniofacial measurements in predicting sex. Materials and Method The sample consisted of 113of true lateral cepha
... Show MoreMobile advertising has become the product of an influential actor in the creation of design ideas that attract the recipient, according to the needs of the society and the interactions of the technological technical age, what the technologies of the mock programs do and what corresponds to the expectations of the recipient, and what the design methods achieve of synchronization and sound in which all The research has found ways to address the most exciting and important snapshots and focus on diversity and diversity, formality, image and color, and what the optical degrees and chromatography achieve sought to attract attention, which contributes from the point of view of the researchers in the field of accuracy, clarity, attention and co
... Show Moreالمستخلص ورمى هذا البحث الى التعرف على الصورة الذهنية للنقابات المهنية لدى الجمهور المنتمي لها ويهدف هذا البحث لمعرفة الصورة الذهنية التي يحملها جمهور(المنتمي) للنقابات المهنية عن طريق التعامل المباشر مع نقاباتهم و معرفة مؤشرات تلك الصورة ومصادر تشكيلها اذا حددت الباحثة مشكلة بحثها بالتساؤل الرئيس : ( ما الصورة الذهنية للنقابات المهنية لدى جمهورها) والتعرف على صورة النقابات عند الجمهور المنتمي لها و
... Show MoreThe present paper aims at presenting a feminist reading of Shamela. It specifically seeks to show how the patriarchal mentality behind Shamela dismembers all aspects of the positive image of the woman in Pamela so that nothing remains in the public mind but the prevalent stereotypical image. The narrative in Pamela draws a positive picture of a truly pure, honest, moral woman; the narrative of Shamela redraws that picture by positing the stereotypical image of the woman as a lascivious temptress, false creature, immoral person, and shameless prostitute. This image is what patriarchy intends to endure as it has invented it long ago so that it continues to maintain its domination of society.
Background: The immediate effect of breast cancer and its treatment on the patient's psychological status and later adaptation of the patient with diagnosis and treatment of the disease may be led to disturbances in the quality of life of the patients. Objective: To measure Quality of life (QOL) in females with breast cancer, to find the factors that can improve their QOL and to identify the sociodemographic and clinical factors that have an influence on the QOL. Methods: The study sample was a convenient non-random sample of 103 patients diagnosed to have breast cancer at least one month after diagnosis. The data were collected by face-to-face interviews which took about 15-20 minutes with each patient, to fill out a standard questionnaire
... Show MoreImage recognition is one of the most important applications of information processing, in this paper; a comparison between 3-level techniques based image recognition has been achieved, using discrete wavelet (DWT) and stationary wavelet transforms (SWT), stationary-stationary-stationary (sss), stationary-stationary-wavelet (ssw), stationary-wavelet-stationary (sws), stationary-wavelet-wavelet (sww), wavelet-stationary- stationary (wss), wavelet-stationary-wavelet (wsw), wavelet-wavelet-stationary (wws) and wavelet-wavelet-wavelet (www). A comparison between these techniques has been implemented. according to the peak signal to noise ratio (PSNR), root mean square error (RMSE), compression ratio (CR) and the coding noise e (n) of each third
... Show More