Preferred Language
Articles
/
bsj-8111
Determination of Molecular Weight and Viscosity of Irradiated Polystyrene
...Show More Authors

 

The varied applications of polystyrene in various fields of life led to examining the cause of radiation influence on some rheological behavior of commercial Polystyrene (PS) solution in the chloroform (CHCl3) solvent. Polystyrene grains shape samples were irradiated using the radioactive element Cesium- 137 with (9 µci) activity for 10, 20, and 30 minutes. The viscosity of the polymer solution depends on the concentration and size (i.e. molecular weight) of the dissolved polymer. Experimental data showed that the radiation dose affected the value of viscosity (shear, relative, specific, and reduced). The viscosity value significantly reduced at 10 min radiation dose and when increasing the dose, the viscosity value increased up to 30 minutes. Deterioration of the polymer structure was recorded for a 10 minutes radiation dose. With the increase of radiation time, which reached 30 minutes, cross-linking was performed due to the substance gaining additional doses of radiation. The molecular weight of polystyrene increased with the increase of irradiation time, but no value was recorded for a molecular weight higher than 56089, which is for not irradiated polystyrene. The study concluded that the radiation dose is able to control the chemical composition of the polymer, therefore the behavior of the polymer in the solvent is determined by the radiation dose to which it is exposed.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jul 01 2016
Journal Name
Journal Of Engineering
Determination of Mono-crystalline Silicon Photovoltaic Module Parameters Using Three Different Methods
...Show More Authors

For modeling a photovoltaic module, it is necessary to calculate the basic parameters which control the current-voltage characteristic curves, that is not provided by the manufacturer. Generally, for mono crystalline silicon module, the shunt resistance is generally high, and it is neglected in this model. In this study, three methods are presented for four parameters model. Explicit simplified method based on an analytical solution, slope method based on manufacturer data, and iterative method based on a numerical resolution. The results obtained for these methods were compared with experimental measured data. The iterative method was more accurate than the other two methods but more complexity. The average deviation of

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 06 2015
Journal Name
Baghdad Science Journal
The Spectrophotometric Determination of Famotidine Drug via Coupling with Diazotized Metochlopramide Hydrochloride
...Show More Authors

A new, simple and sensitive spectrophotometric method was described for the determination of famotidine (FAM) as a pure material and in pharmaceutical formulation. This method was based on diazotization and coupling reaction between famotidine and diazotized solution of metochlopramide hydrochloride (DMPH) in the presence of phosphate buffer solution to give a compound of azo dye having orange color soluble in water with high absorptivity at a wave length of 478 nm. The data shows that FAM and DMPH combine in the molar ratio of 1:1 at PH 7.0 .The method obeys Beer's law over concentration range of 1-40 ?g.ml-1 of famotidine with a correlation coefficient of 0.9955 and a detection limit of 0.10 ?g.ml-1. The apparent molar absorptivity re

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Oct 03 2016
Journal Name
Applied Research Journal
DETERMINATION OF THE GEOID HEIGHT (GEOID UNDULATION) BY USING MODERN SURVEYING TECHNOLOGIES
...Show More Authors

In this work, a large part of Baghdad University campus has been selected. The determination of Geoidal height for the local area requires Ground Control Points which both Ellipsoidal and Orthometric heights are known to compute the difference between them. The first step of the leveling process began by selected the Ground Control Points (GCPs) around the area of the work, and then divided them into two groups of the network traverse stations. They were leveled and adjusted depend on the number of the Bench Marks (B.M.s). Total Station TS (Nikon Nivo 5C) and Global Positioning System (GPS-Garmin 78 map) are used to do this application. The aim of the proposed work was to determine the height of the Geoid surface in the study area. The Geoi

... Show More
Publication Date
Wed Mar 08 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Carbamazepine Via Oxidative Coupling Reaction with 2,4-dinitrophenyl hydrazine
...Show More Authors

 An accurate and sensitive spectrophotometric method has been developed for the determination of carbamazepine (CRN.) in pure and dosage forms. The method is based on the oxidation of 2,4-dinitrophenylhydrazine (2,4-DNPHz) by potassium periodate than coupling with carbamazepine (CRN.) in alkaline medium to form a stable yellowish brown colored water-soluble dye with a maximum absorption at 485 nm. The variables that affect the completion of reaction have been carefully optimized. Beer’s law is obeyed over the concentration range of     (4-50 μg.mL-1) with molar absorptivity of (6.7335×103 L.mol-1.cm1). The limit of detection was (0.1052 μg.mL-1) and Sandell’s sensitivity value was 0.0350 μg.cm-2.

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 30 2018
Journal Name
Iraqi Journal Of Physics
Determination of radioactive concentrations in Tigris river soil samples in Baghdad province
...Show More Authors

In this study, the amounts of activity concentrations of naturally occurring in 10 soil samples of the Tigris river and surrounding areas collected from deferent city of Baghdad have been investigated. Tigris river is an important water source for irrigation and drinking in Iraq. This study was done during 2018 in Protection Center of the Iraqi Ministry of Health and Environment using a high purity germanium detector. The resolution of (HPGe) at 2keV and 30% efficiency. The results of soil sample obtained showed that the effective activity concentration of 40K are ranged from 181.4 Bq/kg in sample S6 to 286.4 Bq/kg in S7. For Raeq values are ranged from 6 Bq/m3 in sample S5 to 17 Bq/m3 in sample S3. The obtained data revealed that the me

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Sep 01 2024
Journal Name
Green Analytical Chemistry
Green methods for determination of paracetamol in drug samples: A comparative study
...Show More Authors

View Publication
Scopus (25)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Sun Mar 17 2019
Journal Name
Baghdad Science Journal
Geolocation Android Mobile Phones Using GSM/UMTS
...Show More Authors

The proliferation of cellular network enabled users through various positioning tools to track locations, location information is being continuously captured from mobile phones, created a prototype that enables detected location based on using the two invariant models for Global Systems for Mobile (GSM) and Universal Mobile Telecommunications System (UMTS). The smartphone application on an Android platform applies the location sensing run as a background process and the localization method is based on cell phones. The proposed application is associated with remote server and used to track a smartphone without permissions and internet. Mobile stored data location information in the database (SQLite), then transfer it into location AP

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Fri Oct 04 2024
Journal Name
Analytical And Bioanalytical Chemistry Research
Optimization and Validation of a GC-FID/QuEChERS Method for Quantitative Determination of Spiromesifen Residues in Tomato Fruits, Leaves and Soil Matrices
...Show More Authors

Pesticides serve a crucial function in contemporary farming practices, safeguarding agricultural crops against pest infestations and boosting production outputs. However, indiscriminate use has caused environmental and human health damage. This study aimed to develop and validate a gas chromatography-flame ionization detection (GC-FID) methodology for the direct and routine analysis of spiromesifen residues in soil, leaves, and tomato fruits. The proposed method prioritizes simplicity by avoiding derivatization steps, offering advantages over existing approaches that utilize lengthy multi-step extraction or derivatization prior to GC analysis. A key novelty of this work is the development of a QuEChERS extraction coupled directly to GC-FID

... Show More
Scopus (3)
Scopus
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Synthesis ,spectroscopic study of Antipyryl azo 2-Naphthol and use it as new reagent for determination of Co(II) and Cu(II)
...Show More Authors

A simple ,accurate and sensitive spectrophotometric method has been developed the determination of Cobalt(II) and Cupper (II) .The method is based on the chelation of Co(II) and Cu(II) ions with 4-(4´-pyrazolon azo) -2-Naphthol(APAN) in aqueous medium . The complexes have a maximum absorption at (513) and (506) nm and ? max 0.531×10 4 and 0.12×10 5 L.mol -1.cm -1 for Co(II) and Cu(II) respectively .The reagent and two complexes have been prepared in ethanolic solution.The stoichiometry of both complexes were found to be 1:2 (metal :legend) .The effects of various cations and anions on Co(II) and Cu(II) determination have been investigated .The stability constants and standard deviations for Co(II) and Cu(II) 0.291 x107 ,0.909X108 L.mol

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 30 2025
Journal Name
International Journal Of Environmental Analytical Chemistry
Comparative study of extraction and spectrophotometric determination of salbutamol sulphate by Fe3O4/SiO2/CPC and Fe3O4/Al2O3/CPC adsorbents: analytical greenness profile
...Show More Authors

ABSTRACT This study developed two adsorbents for extracting salbutamol sulphate (SAS) from water and urine samples after derivatisation with 2-aminobenzothiazole as a colour reagent. These adsorbents include cetylpyridinium chloride surfactant (CPC) modified silica and alumina-coated magnetite nanoparticles (Fe3O4/SiO2/CPC and Fe3O4/Al2O3/CPC). The derivatisation of SAS with the colour reagent resulted in an orange azo dye with maximum adsorption wavelengths of 443.0 nm. UV–Vis spectroscopy was used to identify the target analyte following the magnetic solid-phase extraction (MSPE) method. Under optimal conditions, the concentration ranges of 0.03–5.00 µg/mL and 0.05–6.00 µg/mL with good linearity (˃ 0.99), the detection limi

... Show More
Scopus