Proteus mirabilis is considered as a third common cause of catheter-associated urinary tract infection, with urease production, the potency of catheter blockage due to the formation of biofilm formation is significantly enhanced. Biofilms are major virulence factors expressed by pathogenic bacteria to resist antibiotics; in this concern the need for providing new alternatives for antibiotics is getting urgent need, This study aimed to explore whether green synthesized zinc oxide nanoparticles (ZnO NPs) can function as an anti-biofilm agent produced by P.mirabilis. Bacterial cells were capable of catalyzing the biosynthesis process by producing reductive enzymes. The nanoparticles were synthesized from cell free extract of P.mirabilis. Characterization of biosynthesized zinc nanoparticles was carried out to determine the chemical and physical properties of the product using AFM, TEM, FESEM, XRD and UV visible spectrometry. The hexagonal structure was confirmed by XRD, Particle size was marked at 84.45 nm by TEM, FESEM was used to confirm the surface morphology. AFM analysis was used to reveal the roughness and distribution of nanoparticles. UV–visible spectra of the synthesized nanoparticles recorded maximum peak at 287 nm. Zinc nanoparticles showed remarkable biofilm inhibitory effect on clinical isolates of multidrug resistant Proteus mirabilis. Strong biofilm producer strains show weak biofilm production After incubation for 24 and 48 hours at 37Co with 32 μg/ml sub -MIC concentration of ZnO nanoparticles. Down regulation changes in LuxS expression using Real time PCR technology were detected after treatment with zink nanoparticles of these isolates compared to untreated isolates. From all findings conducted by this study, zinc oxide nanoparticles can function as anti-bacterial agent in concentration dependent manner.
In this research a local adsorbent was prepared from waste tires using two-step pyrolysis method. In the carbonization process, nitrogen gas flow rate was 0.2L/min at carbonization temperature of 500ºC for 1h. The char products were then preceded to the activation process at 850°C under carbon dioxide (CO2) activation flow rate of 0.6L/min for 3h. The activation method produced local adsorbent material with a surface area and total pore volume as high as 118.59m2 /g and 0.1467cm3/g, respectively. The produced . local adsorbent (activated carbon) was used for adsorption of lead from aqueous solution. The continuous fixed bed column experiments were conducted. The adsorption capacity performance of prepared activated carbons in this work
... Show MoreThe aim of this study was to know ( the impact of education differentiated strategy to modify the alternative developments of geographical concepts when students first grade average) .
To achieve the goal of this study , researcher relied on the experimental design of a partial set , the design is ( the experimental group with a control group of post-test ).
&nbs
... Show MoreThis paper aims to study the effect of circular Y-shaped fin arrangement to improve the low thermal response rates of a double-tube heat exchanger containing Paraffin phase change material (PCM). ANSYS software is employed to perform the computational fluid dynamic (CFD) simulations of the heat exchanger, including fluid flow, heat transfer, and the phase change process. The optimum state of the fin configuration is derived through sensitivity analysis by evaluating the geometrical parameters of the Y-shaped fin. For the same height of the fins (10 mm), the solidification time is reduced by almost 22%, and the discharging rate is enhanced by almost 26% using Y-shaped fins compared with the straight fins. The results demonstrate that the sol
... Show MoreThis paper presents ABAQUS simulations of fully encased composite columns, aiming to examine the behavior of a composite column system under different load conditions, namely concentric, eccentric with 25 mm eccentricity, and flexural loading. The numerical results are validated with the experimental results obtained for columns subjected to static loads. A new loading condition with a 50 mm eccentricity is simulated to obtain additional data points for constructing the interaction diagram of load-moment curves, in an attempt to investigate the load-moment behavior for a reference column with a steel I-section and a column with a GFRP I-section. The result comparison shows that the experimental data align closely with the simulation
... Show MoreIntravascular embolisation of foreign bodies (FB) is a rare, serious complication that may occur during central venous line insertion. A 39-yearold male in a critical condition presented to casualty department with a through-and-through chest gunshot wound. Chest X-ray showed left haemothorax; an urgent chest tube was introduced and central venous access was introduced via the right femoral vein. The guided wire used in the procedure was unintentionally pushed to reach the right ventricular apex. Echocardiography confirmed FB location. Once stabilised, the patient was referred to Iraqi Centre of Cardiac Diseases, where transcatheter retrieval was performed. To stabilise the FB, a 6F pigtail catheter was used to create a U-shaped loop in the
... Show MoreSolid‐waste management, particularly of aluminum (Al), is a challenge that is being confronted around the world. Therefore, it is valuable to explore methods that can minimize the exploitation of natural assets, such as recycling. In this study, using hazardous Al waste as the main electrodes in the electrocoagulation (EC) process for dye removal from wastewater was discussed. The EC process is considered to be one of the most efficient, promising, and cost‐effective ways of handling various toxic effluents. The effect of current density (10, 20, and 30 mA/cm2), electrolyte concentration (1 and 2 g/L), and initial concentration of Brilliant Blue dye (15 and 30 mg/L) on
Background: Background : Patients with non-rheumatic atrial fibrillation have high risk of thromboembolism especially ischemic stroke usually arising from left atrial appendage .Transoesophageal echocardiography provides useful information for risk stratification in these patients as it detects thrombus in the left atrial or left atrial appendage. Objective : This study was conducted at Al-Kadhimiya Teaching Hospital to assess the prevalence of left atrial chamber thrombi in patients with chronic non-rheumatic atrial fibrillation using transoesophageal echocardiography and its clinical significance as well as to verify the superiority of transoesophageal over transthoracic echocardiography in the detection of these abnormalities. Type of
... Show MoreIn this study the Entrance Surface Dose (ESD) received by pediatrics patients undergoing chest, abdomen and skull X-ray examinations was estimated. The study was conducted in two hospitals in Najaf city where three radiographic systems were considered. The study participants were classified into four age groups 0-1 , 1-5 , 5-10 and 10-15 years. Calculations were performed using exposure factors, kVp, mAs and focal-skin distance, together with patient data age. The ESD was calculated for the involved patients who underwent an Antero-posterior (AP) chest, abdomen and skull X-ray examination. The resulted data were analyzed and compared with international dose references. For all studied radiographic examinations and all X-ray mac
... Show MoreBackground: Radial neck fractures in children account for 5 to 10% of all elbow fractures in children. They are extra-articular fractures of the radius proximal to the bicipital tuberosity. The physis is typically involved as a Salter-Harris I or II pattern. Alternatively, the fracture sometimes is extraphyseal, through the metaphysis. In children there is considerable potential for remodeling after these fractures. Up to 30° of radial head tilt and up to 3 mm of transverse displacement are acceptable. Many modalities of treatment are available regarding Surgical &Non-Surgical treatments. Objectives: To evaluate the functional outcome after surgical percutaneous joystick reduction therapy of severely angulated radial neck fracture i
... Show More