Preferred Language
Articles
/
bsj-7775
Investigate Spectroscopic Experimental and Theoretical Model for Hemoglobin Nanoscale Solution
...Show More Authors

In the current study, haemoglobin analytes dissolved in a special buffer (KH2PO4(1M), K2HPO4(1M)) with pH of 7.4 were used to record absorption spectra measurements with a range of concentrations from (10-8 to 10-9) M and an absorption peak of 440nm using Broadband Cavity Enhanced Absorption Spectroscopy (BBCEAS) which is considered a simple, low cost, and robust setup. The principle work of this technique depends on the multiple reflections between the light source, which is represented by the Light Emitting Diode 3 W, and the detector, which is represented by the Avantes spectrophotomer. The optical cavity includes two high reflectivity  ≥99%  dielectric mirrors (diameter 25mm, radius of curvature 100mm) and a quartz cuvette  1 cm  to put the samples in the system. This system is also composed of some lenses, aires, and optical fibres to transfer the light from the light source to the optical cavity and after that to the detector. This setup is considered ~3-fold more sensitive when it is compared with another spectroscopic technique as it reduces the effect of noise due to fluctuations in the light intensity. Additionally, the theoretical study estimated the absorption spectra of the haemoglobin concentrations using Table Curve 2D software. The absorption spectra curve was fitted using a suitable curve-fitting equation for these spectra, which was represented by the Gaussian function. The similarity of the theoretical and practical spectra demonstrated that the estimated models can replace the experimental measurements, which leads to a reduction in the cost and time required for the absorption spectroscopy measurements

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Mar 21 2019
Journal Name
Journal Of The College Of Languages (jcl)
LAS TENDENCIAS MODERNAS EN LA CRÍTICA LITERARIA: EL ESTRUCTURALISMO Y EL FORMALISMO EN LA INTERPRE TACIÓN DE TEXTOS LITERARIOS RECENT TRENDS IN LITERARY CRITICISM: THE STRUCTURAL AND FORMALISM IN THE INTERPRETATION OF LITERARY TEXTS
...Show More Authors

El estudio se clasifica dentro los estudios teóricos sobre literatura que se ocupa del estudio de los métodos de la crítica literaria: El Estructralismo literario francés y el Formalismo ruso del siglo XX que se utilizan en la interpretación literaría. Las dos corrientes literarias estudian la literatura como ciencia que busca aplicar un método científico al estudio de la literatura. Dicho estudio trata de exponer las teorías críticas que surgen en el debate de la interpretación de los textos literarios como el de Susan Sontag, Ricoeur Paul y Mijail Bajitin, etc. Además se incluye algunos ejemplos implican el análisis estructuralista y formalista como Kafka y la tragedia Judía. y Sur Racine.

ABSTRACT:

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 01 2022
Journal Name
Eurasian Chemical Communications
Assessment of hypoxemia status by measuring serum level of hypoxia inducible factor 1 alpha in relation to tumor suppression protein p53, estradiol and tumor proliferation markers of breast cancer in Thi-Qar province/Iraq
...Show More Authors

Scopus (9)
Scopus Clarivate
Publication Date
Mon Apr 01 2019
Journal Name
International Journal Of Electrical And Computer Engineering (ijece)
Compared to wireless deployment in areas with different environmentse
...Show More Authors

<p>In the mobile phone system, it is highly desirable to estimate the loss of the track not only to improve performance but also to achieve an accurate estimate of financial feasibility; the inaccurate estimate of track loss either leads to performance degradation or increased cost. Various models have been introduced to accurately estimate the path loss. One of these models is the Okomura / Hata model, which is recommended for estimating path loss in cellular systems that use micro cells. This system is suitable for use in a variety of environments. This study examines the comparison of path loss models for statistical analysis derived from experimental data collected in urban and suburban areas at frequencies of 150-1500 MHz

... Show More
View Publication
Crossref
Publication Date
Tue Jan 08 2019
Journal Name
Lubricants
Influence of Sample Mixing Techniques on Engine Oil Contamination Analysis by Infrared Spectroscopy
...Show More Authors

For the most reliable and reproducible results for calibration or general testing purposes of two immiscible liquids, such as water in engine oil, good emulsification is vital. This study explores the impact of emulsion quality on the Fourier transform infrared (FT-IR) spectroscopy calibration standards for measuring water contamination in used or in-service engine oil, in an attempt to strengthen the specific guidelines of ASTM International standards for sample preparation. By using different emulsification techniques and readily available laboratory equipment, this work is an attempt to establish the ideal sample preparation technique for reliability, repeatability, and reproducibility for FT-IR analysis while still considering t

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Mon Feb 18 2019
Journal Name
Lubricants
Terahertz Time Domain Spectroscopy to Detect Different Oxidation Levels of Diesel Engine Oil
...Show More Authors

Diesel engine oil was subjected to thermal oxidization (TO) for six periods of time (0 h, 24 h, 48 h, 72 h, 96 h, and 120 h) and was subsequently characterized by terahertz time domain spectroscopy (THz-TDS). The THz refractive index generally increased with oxidation time. The measurement method illustrated the potential of THz-TDS when a fixed setup with a single cuvette is used. A future miniaturized setup installed in an engine would be an example of a fixed setup. For the refractive index, there were highly significant differences among the oxidation times across most of the 0.3–1.7 THz range.

View Publication
Scopus (10)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Mon Aug 11 2025
Journal Name
Scientific Reports
An in vitro evaluation of the mineralization effect of a marine collagen supplement on early enamel lesions
...Show More Authors

The marine collagens are biocompatible and biodegradable materials that are considered as a biomimetic approach for tissue regeneration. This study evaluated the effect of daily consumption of marine collagen supplement drink on enamel white spot lesions (WSLs), comparing the results against Regenerate system and Sylc air abrasion methods. Fifty human enamel slabs were allocated into five groups (n = 10 per group): non-treated (sound); non-treated (WSLs, 8% methylcellulose gel with 0.1 M lactic acid (pH 4.6) at 37 °C for 21 days); and three treated surfaces with marine collagen; Regenerate system; and Sylc air abrasion. The treatment lasted for 28 days followed by four weeks’ storage in artificial saliva (pH = 7.0, 37 °C). Evalu

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Mon Oct 01 2007
Journal Name
Journal Of Educational And Psychological Researches
فاعلية المعلمين في تطبيق نموذج بنائي في تدريس العلوم للصف الثاني الاساسي في بغداد
...Show More Authors

        

 هدفت هذه الدراسة الى التعرف على مدى فاعلية المعلمين في تطبيق نموذج بنائي في تدريس مادة العلوم للصف الثاني الأساسي . وقد استخدمت استراتيجيات نوعية في جمع البيانات وتحليلها . وأوضحت نتائج الدراسة ان المعلمين تقربوا أكثر إلى السلوك البنائي , وابدوا رغبة في استخدام استراتيجيات بنائية في تدريسهم للعلوم . واختتمت الدراسة بمجموعة من التوصيات .

  &nbsp

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 24 2019
Journal Name
Iraqi Journal Of Physics
The optical properties of a- (GeS2)100-xGax thin films
...Show More Authors

Thin films whose compositions can be expressed by (GeS2)100-xGax (x=0, 6,12,18) formula were obtained by thermal evaporation technique  of bulk material at a base pressure of ~10-5 torr. Optical transmission spectra of the films were taken in the range of 300-1100 nm then the optical band gap, tail width of localized states,  refractive index, extinction coefficient were calculated. The optical constants were found to increase at low concentration of Ga (0 to12%) while they decreases with further addition of Ga. The optical band gap was found to change in opposite manner to that of optical constants. The variation in the optical parameters are explained in terms of average bond energy

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Apr 12 2019
Journal Name
Journal Of Economics And Administrative Sciences
The robust estimators of reliability function using sample technique AM & POT
...Show More Authors

Abstract 

The Phenomenon of Extremism of Values ​​(Maximum or Rare Value) an important phenomenon is the use of two techniques of sampling techniques to deal with this Extremism: the technique of the peak sample and the maximum annual sampling technique (AM) (Extreme values, Gumbel) for sample (AM) and (general Pareto, exponential) distribution of the POT sample. The cross-entropy algorithm was applied in two of its methods to the first estimate using the statistical order and the second using the statistical order and likelihood ratio. The third method is proposed by the researcher. The MSE comparison coefficient of the estimated parameters and the probability density function for each of the distributions were

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 18 2020
Journal Name
Baghdad Science Journal
Cr2O3:TiO2 Nanostructure Thin Film Prepared by Pulsed Laser Deposition Technique as NO2 Gas Sensor
...Show More Authors

Pulsed laser deposition (PLD) technique was applied to prepared Chromium oxide (Cr2O3) nanostructure doped with Titanium oxide (TiO2) thin films at different concentration ratios 3,5,7 and 9 wt % of TiO2. The effect of TiO2 dopant on the average size of crystallite of the synthesized nanostructures was examined by X-ray diffraction. The morphological properties were discussed using atomic force microscopy(AFM). Observed optical band gap value ranged from 2.68 eV to 2.55 eV by ultraviolet visible(UV-Vis.) absorption spectroscopy with longer wave length shifted  in comparison with that of the bulk Cr2O3 ~3eV. This indicated that the synthesized samples a

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (8)
Scopus Clarivate Crossref