In the current study, haemoglobin analytes dissolved in a special buffer (KH2PO4(1M), K2HPO4(1M)) with pH of 7.4 were used to record absorption spectra measurements with a range of concentrations from (10-8 to 10-9) M and an absorption peak of 440nm using Broadband Cavity Enhanced Absorption Spectroscopy (BBCEAS) which is considered a simple, low cost, and robust setup. The principle work of this technique depends on the multiple reflections between the light source, which is represented by the Light Emitting Diode 3 W, and the detector, which is represented by the Avantes spectrophotomer. The optical cavity includes two high reflectivity ≥99% dielectric mirrors (diameter 25mm, radius of curvature 100mm) and a quartz cuvette 1 cm to put the samples in the system. This system is also composed of some lenses, aires, and optical fibres to transfer the light from the light source to the optical cavity and after that to the detector. This setup is considered ~3-fold more sensitive when it is compared with another spectroscopic technique as it reduces the effect of noise due to fluctuations in the light intensity. Additionally, the theoretical study estimated the absorption spectra of the haemoglobin concentrations using Table Curve 2D software. The absorption spectra curve was fitted using a suitable curve-fitting equation for these spectra, which was represented by the Gaussian function. The similarity of the theoretical and practical spectra demonstrated that the estimated models can replace the experimental measurements, which leads to a reduction in the cost and time required for the absorption spectroscopy measurements
Among the different passive techniques heat pipe heat exchanger (HPHE) seems to be the most effective one for energy saving in heating ventilation and air conditioning system (HVAC). The applications for nanofluids with high conductivity are favorable to increase the thermal performance in HPHE. Even though the nanofluid has the higher heat conduction coefficient that dispels more heat theoretically but the higher concentration will make clustering .Clustering is a problem that must be solved before nanofluids can be considered for long-term practical uses. Results showed that the maximum value of relative power is 0.13 mW at nanofluid compared with other concentrations due to the low density of nanofluid at this concentration. For highe
... Show MoreIn present project, new Schiff base of 4, 4'- (((1E, 1'E)-1,4-.phenylenebis- (methane-ylylidene))-bis-(azane-ylylidene)) bis-(5-(4-chlorophenyl) -4H -1,2,4-triazole-3-thione) (L3) has been synthesized by condensation of 4-amino-5-(4-chlorophenyl)-2,4-dihydro-3H-1,2,4-triazole-3-thione with benzene-1,4-dicarboxaldehyde. The new asymmetrical Schiff base (L3) used as a ligand to synthesize a new complex with Co(II), Ni(II), Cu(II), Pd(II), and Pt(IV) metal ions by 1:2 (Metal: ligand) ratio. New ligand and their complexes have been exanimated and Confirmed by Fourier-transform infrared (FT-IR), Ultraviolet-visible (UV-visible), Proton nuclear magnetic resonance (1HNMR), carbon13 nuclear magnetic resonance (13CNMR), carbon-hydrogen nitrogen sulf
... Show MoreAbstract Background Hemoglobin A1c (HbA1c) is a widely used test for glycemic control. It is done for chronic kidney disease (CKD) patients. Renal disease is accompanied by thyroid abnormalities, which affect HbA1c, especially in those taking erythropoiesis-stimulating agents (ESAs). We aimed to find the effect of thyroid dysfunction on HbA1c in hemodialysis patients taking ESAs and those who do not. Materials and Method Fifty six patients were included in this study, which was done between September 2017 and June 2018, in Baghdad Teaching Hospital. Thyroid stimulating hormone, free T3, free T4 and HbA1c measurements were done. The patients were divided into 2 groups; those who took ESAs and those who did not, then they were subdivided into
... Show MoreBackground: Hemoglobin A1c (HbA1c) is a widely used test for glycemic control. It is done for chronic kidney disease (CKD) patients. Renal disease is accompanied by thyroid abnormalities, which affect HbA1c, especially in those taking erythropoiesis-stimulating agents (ESAs). We aimed to find the effect of thyroid dysfunction on HbA1c in hemodialysis patients taking ESAs and those who do not. Materials and Method: Fifty six patients were included in this study, which was done between September 2017 and June 2018, in Baghdad Teaching Hospital. Thyroid stimulating hormone, free T3, free T4 and HbA1c measurements were done. The patients were divided into 2 groups; those who took ESAs and those who did not, then they were subdivided into those
... Show MoreIn this paper, the complexes of Shiff base of Methyl -6-[2-(diphenylmethylene)amino)-2-(4-hydroxyphenyl)acetamido]-2,2-dimethyl-5-oxo-1-thia-4-azabicyclo[3.2.0]heptane-3-carboxylate (L) with Cobalt(II), Nickel(II), Cupper(II) and Zinc(II) have been prepared. The compounds have been characterized by different means such as FT-IR, UV-Vis, magnetic moment, elemental microanalyses (C.H.N), atomic absorption, and molar conductance. It is obvious when looking at the spectral study that the overall complexes obtained as monomeric structure as well as the metals center moieties are two-coordinated with octahedral geometry excepting Co complexes that existed as a tetrahedral geometry. Hyper Chem-8.0.7
... Show MoreAbstract
A new type of solar air heater was designed, fabricated, and tested in Baghdad, Iraq winter conditions. The heater consists of two main parts. The horizontal section was filled with the black colored iron chip while the vertical part has five pipes filled with Iraqi paraffin wax. A fan was fixed at the exit of the air. Two cases were studied: when the air moved by natural convection and when forced convection moved it. The studied air heater has proven its effectiveness as it heated the air passing through it to high temperatures. The results manifest that using little air movement makes the temperatures, stored energies, and efficiencies of the two studied cases converge
... Show MoreIn current article an easy and selective method is proposed for spectrophotometric estimation of metoclopramide (MCP) in pharmaceutical preparations using cloud point extraction (CPE) procedure. The method involved reaction between MCP with 1-Naphthol in alkali conditions using Triton X-114 to form a stable dark purple dye. The Beer’s law limit in the range 0.34-9 μg mL-1 of MCP with r =0.9959 (n=3) after optimization. The relative standard deviation (RSD) and percentage recoveries were 0.89 %, and (96.99–104.11%) respectively. As well, using surfactant cloud point extraction as a method to extract MCP was reinforced the extinction coefficient(ε) to 1.7333×105L/mol.cm in surfactant-rich phase. The small volume of organi
... Show More