Dapagliflozin is a novel sodium-glucose cotransporter type 2 inhibitor. This work aims to develop a new
validated sensitive RP-HPLC coupled with a mass detector method for the determination of dapagliflozin, its
alpha isomer, and starting material in the presence of dapagliflozin major degradation products and an internal
standard (empagliflozin). The separation was achieved on BDS Hypersil column (length of 250mm, internal
diameter of 4.6 mm and 5-μm particle size) at a temperature of 35℃. Water and acetonitrile were used as
mobile phase A and B by gradient mode at a flow rate of 1 mL/min. A wavelength of 224nm was selected to
perform detection using a photo diode array detector. The method met the requirement of the International
Conference on Harmonisation for Registration of Pharmaceuticals for Human Use (ICH) for validation. The
molecular weight of impurities and degradation products was estimated using positive ESI-MS. Fifteen
impurities were detected during the analysis of dapagliflozin APIs and the brand Farxiga ® and some generic
products. Three of fifteen detected impurities (H, J and K) exceeded the impurities acceptable limits 0.1%.
Those impurities were isolated using new preparative chromatography then characterized using elemental
analysis, FTIR and NMR.
A novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.
... Show MoreAn easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,
... Show MoreKey components estimated in Acol total plant leaves and the results were as follows plant Acol humidity 72%
Weibull distribution is considered as one of the most widely distribution applied in real life, Its similar to normal distribution in the way of applications, it's also considered as one of the distributions that can applied in many fields such as industrial engineering to represent replaced and manufacturing time ,weather forecasting, and other scientific uses in reliability studies and survival function in medical and communication engineering fields.
In this paper, The scale parameter has been estimated for weibull distribution using Bayesian method based on Jeffery prior information as a first method , then enhanced by improving Jeffery prior information and then used as a se
... Show MoreFour rapid, accurate and very simple derivative spectrophotometric techniques were developed for the quantitative determination of binary mixtures of estradiol (E2) and progesterone (PRG) formulated as a capsule. Method I is the first derivative zero-crossing technique, derivative amplitudes were detected at the zero-crossing wavelength of 239.27 and 292.51 nm for the quantification of estradiol and 249.19 nm for Progesterone. Method II is ratio subtraction, progesterone was determined at λmax 240 nm after subtraction of interference exerted by estradiol. Method III is modified amplitude subtraction, which was established using derivative spectroscopy and mathematical manipulations. Method IIII is the absorbance ratio technique, absorba
... Show MoreNarcissus tazetta, a member of the Amaryllidaceae family, is known to be rich in bioactive metabolites such as alkaloids, phenolics and flavonoids, which have been found in nearly every species in this family. N. tazetta cultivated in Iraq, had not previously been studied for its active components; thus, the current study used phytochemical screening and phenolic compounds estimation, both qualitatively and quantitatively. Results showed that the plant alcoholic extract was rich in alkaloids, polyphenols and flavonoids besides tannins, polysaccharides and saponins. Qualitatively; TLC and HPLC chromatogram for total phenolics and flavonoids compounds revealed the presence of Gallic acid (GA), Caffeic acid (CA), Paracumar
... Show MoreSummary
Praise be to God, Lord of the Worlds, and prayers and peace be upon the Master of the Messengers, Muhammad, and upon all his family and companions.
The circle of taboos in the Jewish Sharia is wider than other laws, as the Jews have severe and very complicated rituals in the matter of food, which may not be found among other people of other religions, as the dietary laws that specify foods and drinks forbidden in the Jewish Sharia include very diverse topics. The Torah specified all these laws with several texts
Tannin acyl hydrolase as the common name of tannase is an inducible extracellular enzyme that causes the hydrolysis of galloyl ester and depside bonds in tannins, yielding gallic acid and glucose. The main objective of this study is to find a novel gallic acid and tannase produced by
The question of estimation took a great interest in some engineering, statistical applications, various applied, human sciences, the methods provided by it helped to identify and accurately the many random processes.
In this paper, methods were used through which the reliability function, risk function, and estimation of the distribution parameters were used, and the methods are (Moment Method, Maximum Likelihood Method), where an experimental study was conducted using a simulation method for the purpose of comparing the methods to show which of these methods are competent in practical application This is based on the observations generated from the Rayleigh logarithmic distribution (RL) with sample sizes
... Show More