Performance Evaluation of a Triple Concentric Tube Heat Exchanger Using Deionized Water and Oil-40

This study examines experimentally the performance of a horizontal triple concentric tube heat exchanger TCTHE made of copper metal using water as cooling fluid and oil-40 as hot fluid. Hot fluid enters the inner annular tube of the TCTHE in a direction at a temperature of 50, 60 and 70 oC and a flow rate of 20 l/hr. On the other hand, the cooling fluid enters the inner tube and the outer annular tube in the reverse direction (counter current flow) at a temperature of 25 oC and flow rates of 10, 15, 20, 25, 30 and 35 l/hr. The TCTHE is composed of three copper tubes with outer diameters of 34.925 mm, 22.25 mm, and 9.525 mm, and thicknesses of 1.27 mm, 1.143 mm, and 0.762 mm, respectively. TCTHE tube's length was 670 mm. Nusselt number, overall heat transfer coefficient, convective heat transfer coefficient (CHTC), friction factor and pressure drop were measured from the obtained experimental results and plotted in graphs against Reynold number and volumetric flow rate of water. These parameters appeared good results in the cooling process. Nusselt numbers increased linearly with DIW flow rate for both C1 and C2 reaching maximum values of 38.25 and 14.64 respectively. CHTC increased linearly with the DIW flow rate for both C1 and C2 reaching maximum values of 2934.3 and 871.7 respectively. Overall heat transfer coefficient of DIW reached maximum values of 296.36 and 251.4 at 35 l/hr for C1 and C2, respectively. Friction factor DIW in C1 and C2 decreased with the volumetric flow rate increases, reaching minimum values of 0.04 and 0.25 respectively. Pressure drop of DIW increased linearly with flow rate reaching maximum values of 81.4 and 4.31 for C1 and C2 respectively. This in turn leads to reduced TCTHE length and size leading to a decrease in the construction cost of the heat exchanger.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Sep 06 2018
Journal Name
Al-khwarizmi Engineering Journal
Performance Augmenting of a Vertical Axis Wind Turbine using Adaptable Convergent Ducting System

Developments are carried out to enhance the performance of vertical axis wind turbines (VAWT). This paper studies the performance of the ducted wind turbine with convergent duct (DAWT). Basically, the duct technique is utilized to provide the desired wind velocity facing the turbine. Methodology was developed to estimate the decisive performance parameter and to present the effect of the convergent duct with different inlet angles. The ducted wind turbine was analyzed and simulated using MATLAB software and numerically using ANSYS-Fluent 17.2. Result of both approaches were presented and showed good closeness for the two cases of covering angles 12  and 20 respectively. Results also showed that the convergent duct with an inlet angl

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Nov 01 2019
Journal Name
Journal Of Engineering
Prediction of Heat Transfer Coefficient and Pressure Drop in Wire Heat Exchanger Working with R-134a and R-600a

An experimental and theoretical works were carried out to model the wire condenser in the domestic refrigerator by calculating the heat transfer coefficient and pressure drop and finding the optimum performance. The two methods were used for calculation, zone method, and an integral method. The work was conducted by using two wire condensers with equal length but different in tube diameters, two refrigerants, R-134a and R-600a, and two different compressors matching the refrigerant type. In the experimental work, the optimum charge was found for the refrigerator according to ASHRAE recommendation. Then, the tests were done at 32˚C ambient temperature in a closed room with dimension (2m*2m*3m). The results showed that th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 30 2017
Journal Name
Journal Of Engineering
Experimental Study on Heat Transfer and Friction Factor Characteristics of Single Layer Graphene Based DI-water Nanofluid in a Circular Tube under Laminar Flow and Different Heat Fluxes as Boundary Conditions

An experimental study was performed to estimate the forced convection heat transfer performance and the pressure drop of a single layer graphene (GNPs) based DI-water nanofluid in a circular tube under a laminar flow and a uniform heat flux boundary conditions. The viscosity and thermal conductivity of nanofluid at weight concentrations of (0.1 to 1 wt%) were measured. The effects of the velocity of flow, heat flux and nanoparticle weight concentrations on the  enhancement of the heat transfer are examined. The Nusselt number of the GNPs nanofluid was enhanced as the heat flux and the velocity of flow rate  increased, and the maximum Nusselt number  ratio (Nu nanofluid/ Nu base fluid)   and thermal performance factor

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Energy Conversion And Management
Simultaneous energy storage and recovery in the triplex-tube heat exchanger with PCM, copper fins and Al2O3 nanoparticles

View Publication
Scopus (234)
Crossref (228)
Scopus Clarivate Crossref
Publication Date
Thu May 31 2012
Journal Name
Al-khwarizmi Engineering Journal
An Experimental Study on the Effect of Shape and Location of Vortex Generators Ahead of a Heat Exchanger

An experimental study is carried out on the effect of vortex generators (Circular and square) on the flow and heat transfer at variable locations at (X = 0.5, 1.5, 2.5 cm) ahead of a heat exchanger with Reynolds number ranging from 62000< Re < 125000 and heat flux from 3000 ≤ q ≤ 8000 W/m2 .

In the experimental investigation, an apparatus is set up to measure the velocity and temperatures around the heat exchanger.                     

The results show that there is an effect for using vortex generators on heat transfer. Also, heat transfer depends on the shape and location. The circular is found t

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Components and Treatments of Oilfield Produced Water

In this study, a review of variety of processes that are used in the treatment produced water prior to reuse or to responsible disposal are presented with their environmental issues and economical benefits. Samples of produced water from five locations in Rumaila oilfield/in south of Iraq were taken and analyzed for their contents of brine, some heavy metals, total suspended solids and oil and grease. Moreover, two samples of water were treated using reverse osmosis technique which showed its ability to treat such contaminated water. The results showed that the environmental impact of produced water arises from its chemical composition; i.e., its salt content, its heavy metals, and hydrocarbon contents.

View Publication Preview PDF
Publication Date
Sun Jun 20 2021
Journal Name
Baghdad Science Journal
Water Quality Assessment of Tigris River Using Overall Index of Pollution (OIP)

This study was performed on the Tigris River (Baghdad city section) during the period between December 2016 and December 2018 to assess seasonal variation in water quality using the Overall Index of Pollution (OIP). The OIP is one of the reliable tools for the assessment of surface water quality. To calculate OIP-values, eight parameters were measured ( pH, Dissolved Oxygen "DO", Biological Oxygen Demand "BOD", Total Dissolved Solid "TDS", Total Hardness "TH", calcium "Ca", Sulphate "SO4" and Alkalinity). The results showed the anthropogenic activities impact of Baghdad population that directly discharge of "inadequate treated" waste water to the river.  OIP values were acceptable (1˃OIP˃ 1.7) in 2011, 2012, 2013 and 2018. However, in

... Show More
View Publication Preview PDF
Scopus (19)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Sun Mar 20 2016
Journal Name
Al-academy
Initial evaluation to the performance of the Iraqi actors playing The role of ( Mackbeth ): مظـفر كاظم محـمد

From 1979 to 1999 several theatricl groups had produced (Mackbeth) by shakespear which were directed by different director and the role being played by different actors. So the questions are: How did those a Iraqi actors approach that character by their performance? Did they interpret the character Truelly as the poet wanted to be. The researcher aims to find out the true performance by the actor who impersonate (mackbeth) as a wicked personality, who had un rational ambition. The researcher also aims to expose the style of acting fallowed by the Iraqi actors in that play. In chapter of review of literature, The researcher discusses the weaning and procedure of the actor performance which include characterization and transformation. He a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Evaluation and Improvement of Manufacturing System Using Computer Software Arena

The main purpose of the paper is to identify the controllability of an existing production system; yogurt production line in Abu Ghraib Dairy Factory which has several machines of food processing and packing that has been studied. Through the starting of analysis, instability in production has been found in the factory. The analysis is built depending on experimental observation and data collection for different processing time of the machines, and statistical analysis has been conducted to model the production system. Arena Software is applied for simulating and analyzing the current state of the production system, and results are expanded to improve the system production and efficiency. Research method is applied to contribute in knowi

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
Thermal Characteristics of Closed Wet Cooling Tower Using Different Heat Exchanger Tubes Arrangement

This paper presents thermal characteristics analysis of a modified Closed Wet Cooling Tower (CWCT) based on heat and mass transfer principles to improve the performance of this tower in Iraq. A prototype of CWCT optimized by added packing was designed, manufactured and tested for cooling capacity of 9 kW. Experiments are conducted to explore the effects of various operational and conformational parameters on the thermal performance. In the test section, spray water temperature and both dry bulb temperature and relative humidity of the air measured at intermediate points of the heat exchanger and packing. Heat exchangers consist of four rows and eight columns for an inline tubes arrangement and six rows and five columns f

... Show More