This study examines experimentally the performance of a horizontal triple concentric tube heat exchanger TCTHE made of copper metal using water as cooling fluid and oil-40 as hot fluid. Hot fluid enters the inner annular tube of the TCTHE in a direction at a temperature of 50, 60 and 70 oC and a flow rate of 20 l/hr. On the other hand, the cooling fluid enters the inner tube and the outer annular tube in the reverse direction (counter current flow) at a temperature of 25 oC and flow rates of 10, 15, 20, 25, 30 and 35 l/hr. The TCTHE is composed of three copper tubes with outer diameters of 34.925 mm, 22.25 mm, and 9.525 mm, and thicknesses of 1.27 mm, 1.143 mm, and 0.762 mm, respectively. TCTHE tube's length was 670 mm. Nusselt number, overall heat transfer coefficient, convective heat transfer coefficient (CHTC), friction factor and pressure drop were measured from the obtained experimental results and plotted in graphs against Reynold number and volumetric flow rate of water. These parameters appeared good results in the cooling process. Nusselt numbers increased linearly with DIW flow rate for both C1 and C2 reaching maximum values of 38.25 and 14.64 respectively. CHTC increased linearly with the DIW flow rate for both C1 and C2 reaching maximum values of 2934.3 and 871.7 respectively. Overall heat transfer coefficient of DIW reached maximum values of 296.36 and 251.4 at 35 l/hr for C1 and C2, respectively. Friction factor DIW in C1 and C2 decreased with the volumetric flow rate increases, reaching minimum values of 0.04 and 0.25 respectively. Pressure drop of DIW increased linearly with flow rate reaching maximum values of 81.4 and 4.31 for C1 and C2 respectively. This in turn leads to reduced TCTHE length and size leading to a decrease in the construction cost of the heat exchanger.
Objective: The study aims at evaluating the psychological support and discharge plan from the hospital provided by nurses for woman undergone hysterectomy.
Methodology: The study uses descriptive design and non-probability (convenient) sample which is consisted of (40) nurses from (8) teaching hospitals in the City of Baghdad within the maternity wards. The study is carried out from 11 November 2020 to 27 June 2021. A observational tool is developed to evaluate the psychological support and the discharge plan after surgery. Content validity and internal consistency reliability are determined through pilot study. Data are collected through the use of the questionnaire and data are analyzed through the use of descriptive and inferentia
Recently, environmental noise has arisen from various sources, such as those from exhaust mufflers of combustion engines found in cars, trucks, or power generators, which produce significant noise during their operation. Controlling the radiated noise from these mufflers is a major factor in improving acoustic comfort and minimizing the impact on the surrounding communities. Numerous research has been presented for this reason by modification of the internal structure of the exhaust muffler. The main objective of this work is to reduce the noise level emitted from exhaust mufflers. This can be achieved by adjusting structure parameters to attenuate the surrounding environment's radiated noise. Analysis of pressure-wave propagation h
... Show MoreThis study was conducted in the poultry field of the Department of Animal Production - Faculty of Agriculture - University of Baghdad (Abu Ghraib) for the period from 28/9/2017 to 9/11/2017 for a period of six weeks (42 days), was used in the experiment 300 chick of broiler (Ross 308) one day old. The aim of this study was to effect of adding supplementing different levels of bee pollen (0, 250, 500, 750 and 1000) gm/100kg on Productive Performance. The chicks were randomly distributed in to five treatments, T1 control (without any addition), (T2, T3, T4 and T5) adding bee pollen in the diet 250, 500, 750 and 1000 gm/100kg respectively. The results showed that bee pollen in the diet level 1000 gm/100 kg led to significant increase in the we
... Show MoreThe intensification of competition among all companies and at different levels has become necessary for every company need to continue to improve its performance in order to be able to face the competition and stay in the market. To achieve this, we must rely on the company's accounting information more accurate and appropriate and provided in a timely manner, for the purpose of use in planning and decision making.
So there must be information systems that help the administration to continuous development and improvement of the performance of companies in general, and this is what you need Jordanian companies, especially after the accession of Jordan to the field
... Show MoreThe present study reports the effect of temperature and liquid hourly space velocity (LHSV) on the cumene cracking reaction rate and selectivity by using a laboratory continuous flow unit with fixed bed reactor operating at atmospheric pressure. The prepared HX zeolite was made from Iraqi kaolin with good crystallinity .The activity and selectivity of prepared HX-zeolite was compared with standard HY zeolite and HX zeolite catalysts in the temperature range of 673-823K and LHSV of 0.7-2.5 h-1 . It was found that the cumene conversion increases with increasing temperature and decreasing LHSV at 823K and LHSV of 0.7 h-1 the conversions 65.32, 42.88 and 59.42 mol% for HY, HX and prepared HX catalysts respectively and at LHSV of 2.5 h-1 and th
... Show MoreSloped solar chimney system is a solar chimney power plant with a sloped collector. Practically, the sloped collector can function as a chimney, then the chimney height can be reduced and the construction cost would be reduced.The continuity, Naver-stockes, energy and radiation transfer equations have been solved and carried out by Fluent software. The governing equations are solved for incompressible, 3-D, steady, turbulent standard model with Boussiuesq approximation to develop for the sloped solar chimney system in this study and evaluate the performance of solar chimney power plant in Baghdad city of Iraq numerically by Fluent (14) software with orking conditions such as solar radiation intensity (30
... Show MoreThe current research illustrates experimentally the effect of series and parallel connection (Z-I Configurations) of flat plate water solar collectors array on the thermal performance of closed loop solar heating system. The study includes the effect of changing the water flow rate on the thermal efficiency. The results show that, the collector's efficiency in series connection is higher than the parallel connection within flow rate level less than (100) ℓ/hr. Moreover, the collector efficiency in parallel connection of (I-Configurations) is more than the (Z- Configurations) with increasing the water flow rate .The maximum daily efficiency for parallel (I-Configurations) and (Z- Configurations) are (55%) and (51%) at w
... Show Moreأن كرة السلة بما تتضمنه من مهارات حركية متنوعة تتطلب من ممارسيها امتلاك عدد من القدرات الحركية الخاصة وبشكل خاص التوافق العضلي العصبي والرشاقة والقوة المميزة بالسرعة، فضلاعن قدرات الإدراك الحس- حركي (إدراك المكان وقوة دفع الكرة سواء بالطبطبة العالية أو الواطئة .... الخ ) لذا تكمن أهمية البحث في إيجاد الطرق والوسائل التي تطور قدرة الطالبة على إدراك قوة دفع الكرة والإحساس بها أثناء تعلم وتدريب الطبطبة بأنواعها ب
... Show MoreHigh-rise structures are a significant indication in contemporary urban improvement, mainly in areas characterized by accelerated urban growth and dense population. This type of building should be designed to withstand severe load conditions. Therefore, using composite structural elements in such structures is required for stronger and durable elements. This paper introduces a finite element analysis model for Concrete Filled Stainless Steel Tubular Columns (CFSST) of (100x100) mm cross-section and (1250) mm length to inspect the impact of concrete compressive strength on the response of (CFSST). The generated model was first evaluated through a comprehensive comparison with experimental research. Then, after the model was used to s
... Show More