The current study sheds light on the measurement and estimation of the radioactivity of radionuclides (238U, 226Ra, 232Th, and 40k) in natural waters of different regions of Nineveh Governorate in Iraq.15 samples were collected from different sources of natural waters, where gamma-ray spectroscopy was used using NaI)TI) sodium iodide detector to determine the concentration of radioactivity in the samples. According to the results, the radioactivity concentration in the tested water sample were ranged from 0.36 ± 0.04-1.57 ± 0.09with an average value of 0.69 ± 0.06 Bq/l for 238U, and 2.9 ± 0.02-0.88 ± 0.03 with an average value of 0.65 ± 0.03 Bq/l for 226Ra Bq/l, and 0.48 ± 0.04-1.36 ± 0.06 with an average value of 0.88 ± 0.05 Bq/l for 232Th, while for 40K 13.00 ± 0.69-36.89 ± 1.12 with an average value of 25.1 ± 0.95 Bq/l, respectively. The results obtained from the water samples are below the safe and standard limits established by UNSCEAR. In addition to calculating the radiological hazard indicators that included Radium equivalent (Raeq), air absorbed dose rate (Dγ), effective annual equivalent dose rate (AEDE), indoor and outdoor radiation hazard (H) indices, lifetime cancer risk (ELCR), gonadotropin equivalent dose (AGDE), and ideal level index of gamma rays (Iγ) has been calculated. To verify its deleterious character. On the other hand, the results showed that the rate of heat production values ranged between 0.006-0.0015 µW/m3, which indicates a low rate of heat production and does not affect the temperature of the Earth's crust. Finally, In addition to physicochemical parameters such as PH, dissolved solids TDS, and electrical conductivity Ec. All tested data are within the permissible limit of WHO standards. The results of the current study can be used to provide essential baseline data for future epidemiological investigations and surveillance programs in the areas under study.
The research work represent a fast and simple method for the determination of methionine using chemiluminescence for the methionine-sodium hydroxide-luminol for the generation of a chemiluminesecent derivative of luminal. The emission was measured by continuous flow analysis made sample size of 83µL was used.Response versus concentration extended from 0.2-20 mM.L-1 with a percentage linearity of 96.17% or with 99.17% percentage of linearity for the range 0.6-20 mM.L-1. Reaching to a L.O.D. at (S/N=3) for 5 µM.L-1 from the gradual dilution for the minimum concentration in the calibration graph with a repeatability of less than 0.5% (n=10). A comparison was made between the new developed method with the classical method for the spectrophoto
... Show MoreSilver Indium Aluminum Selenium AgIn1xAlxSe2 AIAS for x=01 thin films was deposited by thermal evaporation at RT and different︣︢︡ ︠︣1thickness 100 150 and 200 nm on the glass Substrate and p2Si wafer to produce AIAS/p3Si heterojunctionsolarcell4 Structural optical electrical and photovoltaicproperties6 are investigated for the samples XRD analysis reveals that all the deposited AIAS films show polycrystalline structure without any change due to increase of thickness Average diameter and roughness calculated from AFM images shows an increase in its value with increasing thickness The optical absorbance and transmittance for samples are measured using a spectrometer type UV Visible 1800 spectra1photometer to study the energy6gap The
... Show MoreMagnetosphere is a region of space surrounding Earth magnetic field, the formation of magnetosphere depends on many parameters such as; surface magnetic field of the planet, an ionized plasma stream (solar wind) and the ionization of the planetary upper atmosphere (ionosphere). The main objective of this research is to find the behavior of Earth's magnetosphere radius (Rmp) with respect to the effect of solar wind kinetic energy density (Usw), Earth surface magnetic field (Bo), and the electron density (Ne) of Earth's ionosphere for three years 2016, 2017 and 2018. Also the study provides the effect of solar activity for the same period during strong geomagnetic storms on the behavior of Rmp. F
... Show MoreChristianity has rituals and rituals to be carried out, and can not be abandoned, and they see that the sacred statutes ordered by Christ () his followers, including: (the mystery of baptism between Christian denominations, descriptive study) A Christian is to be baptized as the seal of faith, as evidenced by the Bible in the words of Jesus to His disciples.
Baptism takes place in the name of the Father, the Son, and the Holy Spirit. This makes them Christian through the practice of this obligatory man enters the Church, represented by the death, burial, and resurrection of Christ according to their belief. And every person who has received the sacrament of baptism remains a Christian until death, in the light of what they see.
The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser
The toxic lead additives to gasoline are no longer used in many countries around the world. Many other countries are now phasing out the lead in gasoline. Although the lead fuel is still in use in Iraq, several plans are considered to phase out the lead. The use of organic compounds to replace the lead additives in gasoline is considered now as an option in Iraqi refineries. The main objective of this project was preparation of premium gasoline, by blending of gasoline with Alternative additives (alcohol, aromatic) to enhancing octane number of Al-Doura gasoline pool. Improved gasoline was tested by ASTM standard method which includes octane number measuring by CFR engine analyzer. Gasoline pool RON (80) was used and selective components
... Show More