This article studied some linear and nonlinear optical characteristics of different pH solutions from anthocyanin dye extract at 180 oC from red cabbage. First, the linear spectral characteristics, including absorption and transmittance in the range 400-800 nm for anthocyanin solution 5% v/v with different pHs, were achieved utilizing a UV/VIS spectrophotometer. The experimental results reveal a shift in the absorption toward the longer wavelength direction as pH values increment. Then, the nonlinear features were measured using the Z-scan technique with a CW 532 nm laser to measure the nonlinear absorption coefficient through an open aperture. A close aperture (diameter 2 mm) calculates the nonlinear refractive index. The open Z-scan shows that as the pH increases, the sample decreases transmittance, indicative a two-photon absorption process, and the samples act as a collecting lens for the laser beam. In contrast, the results with a closed Z-scan indicate that the nonlinear absorption coefficient displays a self-focusing nonlinearity. Also, the nonlinear susceptibility decreased by increasing the value of the pH solution. Due to obvious anthocyanin dye nonlinearity dependence value on dye pH, it is possible to use the natural anthocyanin dye as a photonic device
The Khabour reservoir, Ordovician, Lower Paleozoic, Akkas gas field which is considered one of the main sandstone reservoirs in the west of Iraq. Researchers face difficulties in recognizing sandstone reservoirs since they are virtually always tight and heterogeneous. This paper is associated with the geological modeling of a gas-bearing reservoir that containing condensate appears while production when bottom hole pressure declines below the dew point. By defining the lithology and evaluating the petrophysical parameters of this complicated reservoir, a geological model for the reservoir is being built by using CMG BUILDER software (GEM tool) to create a static model. The petrophysical properties of a reservoir were computed using
... Show MoreThe research studied and analyzed the hybrid parallel-series systems of asymmetrical components by applying different experiments of simulations used to estimate the reliability function of those systems through the use of the maximum likelihood method as well as the Bayes standard method via both symmetrical and asymmetrical loss functions following Rayleigh distribution and Informative Prior distribution. The simulation experiments included different sizes of samples and default parameters which were then compared with one another depending on Square Error averages. Following that was the application of Bayes standard method by the Entropy Loss function that proved successful throughout the experimental side in finding the reliability fun
... Show MoreAsthma is one of the most common chronic, non-communicable diseases affecting children worldwide. The estimated prevalence of pediatric asthma in Iraq is 15.8%. Physiologic, inflammatory and structural factors contribute to the development of asthma. Assessment and monitoring of asthma control can be done by a validated children asthma control test (CACT). Management of asthma must address three components which are an appropriate management plan, the most appropriate medication if necessary, and the use of safe and effective medication. The management plan should consider patient counseling and education about the definition of asthma, signs, and symptoms, the pathophysiology of asthma, common triggers for asthma and how can avoid them,
... Show MoreThe largest use of x-ray in medical by dentists, employers or persons that needed by patients with specific conditions, lead to higher exposure of x-ray that may cause many diseases. In the present work radiography films have been used in evaluating the efficiency of using unsaturated polyester polymer reinforced with lead oxide (PbO) as shield material for medical x-ray devices, many parameters studied like concentration and thickness that they are increasing the attenuation of x-ray in them. The results show that the attenuation of X-ray increasing with concentration of reinforced material and with thickness, and the optical density decreases with increasing concentration from 0% to 50%, we chose 30% as suitable concentration to increase
... Show More