Wireless Sensor Networks (WSNs) are promoting the spread of the Internet for devices in all areas of
life, which makes it is a promising technology in the future. In the coming days, as attack technologies become
more improved, security will have an important role in WSN. Currently, quantum computers pose a significant
risk to current encryption technologies that work in tandem with intrusion detection systems because it is
difficult to implement quantum properties on sensors due to the resource limitations. In this paper, quantum
computing is used to develop a future-proof, robust, lightweight and resource-conscious approach to sensor
networks. Great emphasis is placed on the concepts of using the BB84 protocol with the AES algorithm in
WSN security. The results of analysis indicated a high level of security between the data by depending on the
generation of secure keys, and reached an accuracy rate of about (80-95) % based on using NIST statistical.
The efficiency of the work increased to 0.704 after using the Quantum Bit Error Rate equation, eventually
increasing the network performance. This results in the reduction of the overall amount of energy, and the time
required for performing the key exchange in the encryption and decryption processes decreased.
Background: Measuring implant stability is an important issue in predicting treatment success. Dental implant stability is usually measured through resonance frequency analysis (RFA). Osstell® RFA devices can be used with transducers (Smartpeg™) that correspond to the implants used as well as with transducers designed for application with Penguin® RFA devices (Multipeg™). Aims: This study aims to assess the reliability of a MultiPeg™ transducer with an Osstell® device in measuring dental implant stability. Materials and Methods: Sixteen healthy participants who required dental implant treatment were enrolled in this study. Implant stability was measured by using an Osstell® device with two transducers, namely, Smartpeg™ and M
... Show MoreIn this work, the nuclear electromagnetic moments for the ground and low-lying excited states for sd shell nuclei have been calculated, resulting in a revised database with 56 magnetic dipole moments and 41 electric quadrupole moments. The shell model calculations are performed for each sd isotope chain, considering the sensitivity of changing the sd two-body effective interactions USDA, USDE, CWH and HBMUSD in the calculation of the one-body transition density matrix elements. The calculations incorporate the single-particle wave functions of the Skyrme interaction to generate a one-body potential in Hartree–Fock theory to calculate the single-particle matrix elements. For most sd shell nuclei, the experimental data are well rep
... Show MoreThe study aimed to explore the effectiveness of using rational judgment strategy in teaching science to develop scientific thinking for second-grade students. The researcher utilized the quasi-experimental approach based on (the pre/post designing) of two groups: experimental and control. As for tools: a test of scientific thinking prepared by the researcher that proved its verification of their validity and reliability. The test applied on a random sample of (66) students, divided into two groups: (34) experimental, and (32) control. The results showed that the experimental group outperformed the control group in the post-application of the scientific thinking test, In each skill separately, and in the total skills. The study recommende
... Show MoreLaser shock peening (LSP) is deemed as a deep-rooted technology for stimulating compressive residual stresses below the surface of metallic elements. As a result, fatigue lifespan is improved, and the substance properties become further resistant to wear and corrosion. The LSP provides more unfailing surface treatment and a potential decrease in microstructural damage. Laser shock peening is a well-organized method measured up to the mechanical shoot peening. This kind of surface handling can be fulfilled via an intense laser pulse focused on a substantial surface in extremely shorter intervals. In this work, Hydrofluoric Acid (HF) and pure water as a coating layer were utilized as a new technique to improve the properti
... Show MoreObjective: To identify causes of maternal death in Mizan Aman and Gebretsadik shawo general hospitals
Methodology: A case control study on 595 charts, 119 cases and 476 controls was conducted in Mizan
Aman & Gebretsadik shawo general hospitals. Data was analyzed by STATA 13.1. Propensity score
matching analysis was used to see causes of maternal death.
Results: Hemorrhage were the main direct causes of maternal death which accounts 47.9% (β =0.58
(95% CI (0.28,0.87)) in hospital but when projected to population based the sample (β =0.26 (95% CI
(0.22,0.31)). Followed by infection 36 (25.21%) (β = 0.50 (95% CI (0.08, 0.92)). when projected to
population based the sample PIH 7.6%) is significant cause (β = 0.16
The aim of the study was to evaluate the efficacy of diode laser (λ=940 nm) in the management of gingival hyperpigmentation compared to the conventional bur method. Materials and methods: Eighteen patients with gingival hyperpigmentation were selected for the study with an age between 12-37 years old. The site of treatment was the upper gingiva using diode laser for the right half and the conventional method for the left half. All patients were re-evaluated after the following intervals: 3 days, 7 days, 1 month and 6 months post-operation. Pain and functions were re-evaluated in each visit for a period of 1 day, 3 days and 1 week post-operation. Laser parameters included 1.5 W in continuous mode with an initiated tip (400 μm) placed in
... Show MoreAbstract: The aim of this study is to assess the effectiveness of 940 nm diode laser in comparison to Endoactivator in elimination of smear layer in terms of radicular dentin permeability and ultra-structural changes of root canal walls by SEM evaluation. Twenty-eight single-rooted extracted lower premolars were instrumented up to size X4 (protaper Next, Dentsaply) and divided into two experimental groups according to the irrigation system, G1; activated by EndoActivator and G2; activated by Diode laser 940 nm, CW mode, 1.7 W. Afterward, the roots were made externally impermeable, filled with 2%methylene blue dye, divided horizontally into three segments representing the apical, middle, and coronal thirds then examined under stereo- micr
... Show MoreThis paper aims to study the rate of star formation (SFR) in luminous infrared galaxies at different wavelengths using distance measurement techniques (dl, dm) and to know which methods are the most accurate to determine the rate of star formation as we present through this research the results of the statistical analysis (descriptive statistics) for a sample of luminous infrared galaxies. The data used in this research were collected from the NASA Extragalactic Database (NED) and HYPERLEDA, then used to calculate the star formation rate and indicate the accuracy of the distance methods used (dl, dm). Two methods were tested on Hα, OII, FIR, radio continuum at 1.4 GHz, FUV, NUV, and total (FUV + FIR). The results showed that the dl
... Show MoreBackground: Masseter muscle is one of the most obvious muscles of mastication and considered as one indicator of jaw muscle activity. It has a major influence on the transverse growth of the midface and the vertical growth of the mandible. This study undertaken to determine the role of cephalometric analysis for discrimination between Cl I and Cl III skeletal relationships, determine the role of ultrasonography in determination of masseter muscle thickness, compare masseter muscle thickness between Cl I and Cl III skeletal relationships, and determine the effect of gender on masseter muscle thickness. Material and Method: The sample of the current study consisted of 70 Iraqi subjects 40 males and 30 females with age ranging 18-25 years. The
... Show MoreIn this work, electrochemical process was presented to polymerized eugenol on Gr.2 and Gr.5 titanium alloys before and after treated by Micro Arc Oxidation (MAO), where Gr.2 is commercial pure titanium and Gr.5 is Ti-6Al-4V dental alloys. The deposited layers were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The adhesion strength of polymeric thin-film was estimation by using pull-off adhesion test and the result was the adhesion strength of PE was (1.23 MPa) on Gr.2 before MAO and increase to (1.98 MPa) on Gr.2 after MAO treatment. The corrosion behavior of Gr.2 and Gr.5 alloy in artificial saliva environment at
... Show More