Preferred Language
Articles
/
bsj-7310
Using the Elzaki decomposition method to solve nonlinear fractional differential equations with the Caputo-Fabrizio fractional operator
...Show More Authors

The techniques of fractional calculus are applied successfully in many branches of science and engineering, one of the techniques is the Elzaki Adomian decomposition method (EADM), which researchers did not study with the fractional derivative of Caputo Fabrizio. This work aims to study the Elzaki Adomian decomposition method (EADM) to solve fractional differential equations with the Caputo-Fabrizio derivative. We presented the algorithm of this method with the CF operator and discussed its convergence by using the method of the Cauchy series then, the method has applied to solve Burger, heat-like, and, couped Burger equations with the Caputo -Fabrizio operator. To conclude the method was convergent and effective for solving this type of fractional differential equations.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jan 17 2014
Journal Name
مجلة دراسات في التاريخ والاثار
نصوص اقتصادية غير منشورة من أرشيف تورام ايلي
...Show More Authors

يعود الأرشيف إلى تورام ايلي التاجر والذي عرف في النصوص أيضا بوكيل التجار(ugula-dam-gàr)، في دوره هذا له سلطة بين التجار في مجتمعه(مجتمع التجار)، يذكر(Garfinkle) أن التجار غالبا ما اكتسبوا ألقابهم عن طريق الوراثة ذلك قد يمنح التجار حق الدخول إلى حسابات المؤسسات العامة. كان تورام ايلي تاجرا نشيطا في أعمال قروض الفضة في أواخر عهود سلالة أور الثالثة(3)، لمدة (ثمان عشرة) سنة أعتبارا من السنة الرابعة من حكم الملك أمارسن وحتى ا

... Show More
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Symmetric and Positive Definite Broyden Update for Unconstrained Optimization
...Show More Authors

Broyden update is one of the one-rank updates which solves the unconstrained optimization problem but this update does not guarantee the positive definite and the symmetric property of Hessian matrix.

In this paper the guarantee of positive definite and symmetric property for the Hessian matrix will be established by updating the vector  which represents the difference between the next gradient and the current gradient of the objective function assumed to be twice continuous and differentiable .Numerical results are reported to compare the proposed method with the Broyden method under standard problems.

View Publication Preview PDF
Scopus (10)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Mar 01 2016
Journal Name
المصرية للدراسات القانونية والاقتصادية
مدى تحقق المنافسة غير المشروعة في حق المؤلف
...Show More Authors

Preview PDF
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Primary Diagnosis of Abnormal Urine via Auto Fluorescence Process
...Show More Authors

The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 16 2008
Journal Name
Iraqi Journal Of Laser
Primary Diagnosis of Abnormal Urine via Auto Fluorescence Process
...Show More Authors

The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Baghdad Science Journal
Determining ACE-2 Level and Some Relevant Biochemical Parameters and studying the effect of Gender in Iraqi Diabetic Patients with Glomeruli and Renal Tubules Fibrosis as Early Prediction Marker
...Show More Authors

     Diabetic kidney disease is an illness of the glomerulus that interferes with the glomerular filtration barrier (GFB), which is worked to enable kidney to selective purification of water and solutes in addition to limiting the movement of large macromolecules such as albumin. In the glomerular endothelium, mesangial cells, foot cells, and the brush border of the proximal tubules, ACE-2 is expressed and that the kidneys represent the highest-expressing region of this enzyme. Thus, the current study aimed to evaluate ACE-2 level in this case compared to healthy condition. The study Conducted with 120 male and female ranging in age (30-65) years old. Ninety patients with type 2 diabetes subdivided into three groups on the basis of A

... Show More
View Publication Preview PDF
Scopus (5)
Scopus Crossref
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
A New method for ISE construction for methyl orange dyes and using for indirect determination of Amitriptyline Hydrochloried drug
...Show More Authors

A new method for construction ion-selective electrode (ISE) by heating reaction of methyl orange with ammonium reineckate using PVC as plasticizer for determination methyl orange and determination Amitriptyline Hydrochloried drug by formation ion-pair on electrode surface . The characteristics of the electrode and it response as following : internal solution 10-4M , pH (2.5-5) ,temperature (20-30) and response time 2 sec. Calibration response for methyl orange over the concentrationrange 10-3 -10-9 M with R=0.9989 , RSD%=0.1052, D.O.L=0.315X10-9 MEre%=(-0.877- -2.76) , Rec%.=(97.230 -101.711) .

View Publication Preview PDF
Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Development of an Eco-Friendly Method for Iron Extraction and Determination in Pharmaceuticals Using Ciprofloxacin Drug as Chelating agent
...Show More Authors

A method is developed for the determination of iron (III) in pharmaceutical preparations by coupling cloud point extraction (CPE) and UV-Vis spectrophotometry. The method is based on the reaction of Fe(III) with excess drug ciprofloxacin (CIPRO) in dilute H2SO4, forming a hydrophobic Fe(III)- CIPRO complex which can be extracted into a non-ionic surfactant Triton X-114, and iron ions are determined spectrophotometrically at absorption maximum of 437 nm. Several variables which impact on the extraction and determination of Fe (III) are optimized in order to maximize the extraction efficiency and improve the sensitivity of the method. The interferences study is also considered to check the accuracy of the procedure. The results hav

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Jan 13 2018
Journal Name
Journal Of Engineering
Zn(II) Removal from Wastewater by Electrocoagulation/Flotation Method using New Configuration of a Split-Plate Airlift Electrochemical Reactor
...Show More Authors

In this paper, split-plate airlift electrochemical reactor as an apparatus with new configuration for wastewater treatment was provided. Two aluminum plates were fixed inside the reactor and present two functions; first it works as split plates for internal loop generation of the airlift system (the zone between the two plates acts as riser while the other two zones act as downcomer) and second it works as two electrodes for electrocoagulation process. Simulated wastewater contaminated with zinc ions was used to test the performance of this apparatus for zinc removal by studying the effect of different experimental variables such as initial concentration of zinc (50-800 ppm), electrical current density (2.67-21.4 mA/cm2), init

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
International Journal Of Nonlinear Analysis And Applications
Big data analysis by using one covariate at a time multiple testing (Ocmt) method: Early school dropout in iraq
...Show More Authors

Scopus (7)
Scopus