The electrospun nanofibers membranes (ENMs) have gained great attention due to their superior performance. However, the low mechanical strength of ENMs, such as the rigidity and low strength, limits their applications in many aspects which need adequate strength, such as water filtration. This work investigates the impact of electrospinning parameters on the properties of ENMs fabricated from polyacrylonitrile (PAN) solved in N, N-Dimethylformamide (DMF). The studied electrospinning parameters were polymer concentration, solution flow rate, collector rotating speed, and the distance between the needle and collector. The fabricated ENMs were characterized using scanning electron microscopy (SEM) to understand the surface morphology and estimate the average fiber sizes. The membrane porosity percentage was measured using the dry-wet weight method. Also, a dynamic mechanical analyzer was used to determine the mechanical strength properties (tensile strength and Young's modulus) (DMA). The obtained results revealed that the polymer concentration and flow rate mainly affect the porosity and fiber size in ENMs. Increasing the polymer concentration improves the strength and flexibility, while the flow rate did not show a clear effect on the mechanical strength of ENMs. Both fibers collecting speed and spinning distance did not clearly impact the membrane morphology. ENMs flexibility significantly increased with increasing the collector speed and decreasing the spinning distance. Strong and flexible ENMs with small fibers can be fabricated using 10% PAN/DMF at a flow rate of 1 mL/h, collector speed of 140 rpm, and spinning distance of 13 cm.
Objectives: The study aims to investigate the efficiency of physiotherapy methods to improve the
degree of the clinical recovery of the peripheral facial palsy.
Methodology: This study is carried out at the Rehabilitation Center-Baghdad from November 2009 till
March 2010. This study includes (40) patient, their ages are from (13) to (55) years old; (24) male and
(16) female with unilateral facial palsy of undetermined cause. House-Brackmann facial recovery
scores have been used before and after the physiotherapy treatment.
Results: The results show that the physiotherapy sessions obtained the best effect of the electrical
stimulation, exercises and massage in the treatment of facial palsy. Highly respondents in femal
This study was designed to evaluate the effect of anesthesia on thyroid hormones (T3, T4, rT3), thyrotropin(TSH), and cortisol levels in patients undergoing major urological surgery. The study included fifty patients scheduled for elective major urological surgery where 70% of the patients underwent general anesthesia, while30% underwent regional anesthesia. All patients were in stable control general conditions. The study showed that the thyroid hormones, thyrotropin and cortisol levels were affected with general anesthesia more than regional. The levels of these hormones responded to anesthetics and surgical stresses. This response was thought to be mainly mediated by afferent neurogenic impulses from the area of injury. Therefore, ab
... Show MoreBackground: The aims of this study were to evaluate the effect of implant site preparation in low-density bone using osseodensification method in terms of implant stability changes during the osseous healing period and peri-implant bone density using CBCT. Material and methods: This prospective observational clinical study included 24 patients who received 46 dental implants that were installed in low-density bone using the osseodensification method. CBCT was used to measure the bone density pre- and postoperatively and implant stability was measured using Periotest® immediately after implant insertion and then after 6 weeks and 12 weeks postoperatively. The data were analyzed using paired t-test and the probability value <0.05 was conside
... Show MoreA simple low-cost approach at various exposure times was utilized to generate cold plasma in the aim to fabricate AuNPs. UV-Visible spectra and X-ray diffraction were used to characterize the nanoparticles (XRD). Surface Plasmon resonance was observed in the synthesized AuNPs at 530, 540, and 533 nm. For all samples, the patterns of XRD show very intensive peaks implying the fcc crystalline structure of AuNPs. The average crystallite size of AuNPs is ranging between 20-30 nm. The observation of morphology by FESEM revealed the spherical formation of AuNPs. Doses of 100 and 200 ppm of AuNPs were adapted to investigate their effect on the blood-mixture with and without a 20-second of cold plasma exposure. The WBC components in the blood
... Show MoreAbstractThe objective of the present study was measured of several oxidative stresses and liver function parameters in workers occupationally exposed to cement dust in Kufa Cement Factory, in order to test the hypothesis that cement dust exposure may perturb these parameters. Assessment of oxidative stress and liver function parameters were performed in 63 workers occupationally, in different departments of Kufa Cement Factory, exposed to cement dust (range of the exposure time was 5-38 years) and 36 matched unexposed controls. The study results illustrated an increasing in the oxidative stress parameters, moreover; liver function parameters showed abnormal results in the exposed workers compared to the unexposed. An increase in theses para
... Show MoreOne of the key molecules in the conversion of sphingosine to sphingosine-1- phosphate is SPHK-1, also known as Sphingosine Kinase 1 (SPHK-1). Sphingosine-1-phosphate (S1P) is a lipid that acts as a signaling molecule and plays an essential role in inflammatory and immunomodulatory responses. S1P has recently been identified as a mediator and a biomarker in inflammatory bone diseases such as osteoporosis and inflammatory osteolysis based on the biological effects of S1P in osteoclastic and osteoblastic cells and immune cells. According to recent research, S1P may play a role in the pathogenesis of periodontitis, an inflammatory bone-destructive condition. This study assesses the salivary level SPHK-1 in periodontitis and its correlat
... Show MoreToday in the digital realm, where images constitute the massive resource of the social media base but unfortunately suffer from two issues of size and transmission, compression is the ideal solution. Pixel base techniques are one of the modern spatially optimized modeling techniques of deterministic and probabilistic bases that imply mean, index, and residual. This paper introduces adaptive pixel-based coding techniques for the probabilistic part of a lossy scheme by incorporating the MMSA of the C321 base along with the utilization of the deterministic part losslessly. The tested results achieved higher size reduction performance compared to the traditional pixel-based techniques and the standard JPEG by about 40% and 50%,
... Show MoreIn this paper, the theoretical cross section in pre-equilibrium nuclear reaction has been studied for the reaction at energy 22.4 MeV. Ericson’s formula of partial level density PLD and their corrections (William’s correction and spin correction) have been substituted in the theoretical cross section and compared with the experimental data for nucleus. It has been found that the theoretical cross section with one-component PLD from Ericson’s formula when doesn’t agree with the experimental value and when . There is little agreement only at the high value of energy range with the experimental cross section. The theoretical cross section that depends on the one-component William's formula and on-component corrected to spi
... Show MoreIn this article, we developed a new loss function, as the simplification of linear exponential loss function (LINEX) by weighting LINEX function. We derive a scale parameter, reliability and the hazard functions in accordance with upper record values of the Lomax distribution (LD). To study a small sample behavior performance of the proposed loss function using a Monte Carlo simulation, we make a comparison among maximum likelihood estimator, Bayesian estimator by means of LINEX loss function and Bayesian estimator using square error loss (SE) function. The consequences have shown that a modified method is the finest for valuing a scale parameter, reliability and hazard functions.