This paper deals with numerical study of the flow of stable and fluid Allamstqr Aniotina in an area surrounded by a right-angled triangle has touched particularly valuable secondary flow cross section resulting from the pressure gradient In the first case was analyzed stable flow where he found that the equations of motion that describe the movement of the fluid
A novel analytical method is developed for the determination of azithromycin. The method utilizes continuous flow injection analysis to enhance the chemiluminescence system of luminol, H2O2, and Cr(III). The method demonstrated a linear dynamic range of 0.001–100 mmol L-1 with a high correlation coefficient (r) of 0.9978, and 0.001–150 mmol L-1 with a correlation coefficient (r) of 0.9769 for the chemiluminescence emission versus azithromycin concentration. The limit of detection (L.O.D.) of the method was found to be 18.725 ng.50 µL−1 based on the stepwise dilution method for the lowest concentration within the linear dynamic range of the calibration graph. The relative standard deviation (R.S.D. %) for n = 6 was less than 1.2%
... Show MoreExcessive water production is a persistent challenge in oil and gas wells, with polymer and gel solutions commonly employed for water control. This study investigates the rheological behaviour of cross-linked polyacrylamide gels and their impact on water shutoff treatment in gas wells. Rheological measurements, coreflooding experiments using Berea sandstone samples, and micromodel flow visualizations were conducted to evaluate gel performance. Results showed that during water injection, the water residual resistance factor ( Frrw ) decreases with increasing flow rates, mainly due to gel shear thinning behaviour and reduced residual gas saturation. Higher polymer concentrations in the gel enhance water permeability reduction. In contrast, un
... Show MoreThe current study was conducted in the environment of the Martyr Monument Lake in the city center of Baghdad during 2019 to monitor the impact of climatic conditions such as drought, water shortage, high temperatures in the environment of the city and the lack of water flow during the years 2015 to 2018 and their effects on some of the physical and chemical factors of water and the dynamics of the phytoplankton community in the lake environment. Heterogeneity of some studied environmental factors, including air and water temperature, permeability, water depth, pH, DO, BOD5, nutrients, nitrate, NO3, and phosphates were found. The results showed the effect of climate change and the pres
After the information revolution that occurred in the Western world, and the developments in all fields, especially in the field of education and e-learning, from an integrated system based on the effective employment of information and communication technology in the teaching and learning processes through an environment rich in computer and Internet applications, the community and the learner were able to access information sources and learning at any time and place, in a way that achieves mutual interaction between the elements of the system and the surrounding environment. After the occurrence of the phenomenon of Covid 19, it led to a major interruption in all educational systems that had never happened before, and the disrupt
... Show MoreThis research is an attempt to achieve the following objectives: 1. identifying the nature of the non-verbal communication skills practiced by educational counselors in individual guidance. 2. Identifying the significant differences between non-verbal communication skills exercised by educational counselors from their point of view in regard to their gender (male-female). The researcher used a questionnaire as a tool prepared based on exploratory questions of educational counselors and literature. It has consisted of (26) items over four domains applied to a sample of (50) educational counselors (male and female) who have been chosen randomly from schools located in Baghdad Education Directorate Rusafa / 2. It was treated statistically u
... Show MoreThis paper analyzes a piled-raft foundation on non-homogeneous soils with variable layer depth percentages. The present work aims to perform a three-dimensional finite element analysis of a piled-raft foundation subjected to vertical load using the PLAXIS 3D software. Parametric analysis was carried out to determine the effect of soil type and initial layer thickness. The parametric study showed that increasing the relative density from 30 % to 80 % of the upper sand layer and the thickness of the first layer has led to an increase in the ultimate load and a decrease in the settlement of piled raft foundations for the cases of sand over weak soil. In clay over weak soil, the ultimate load of the piled raft foundation w
... Show MoreAn optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination
... Show MoreAn experimental and theoretical analysis was conducted for simulation of open circuit cross flow heat
exchanger dynamics during flow reduction transient in their secondary loops. Finite difference
mathematical model was prepared to cover the heat transfer mechanism between the hot water in the
primary circuit and the cold water in the secondary circuit during transient course. This model takes under
consideration the effect of water heat up in the secondary circuit due to step reduction of its flow on the
physical and thermal properties linked to the parameters that are used for calculation of heat transfer
coefficients on both sides of their tubes. Computer program was prepared for calculation purposes which
cover a