Metal contents in vegetables are interesting because of issues related to food safety and potential health risks. The availability of these metals in the human body may perform many biochemical functions and some of them linked with various diseases at high levels. The current study aimed to evaluate the concentration of various metals in common local consumed vegetables using ICP-MS. The concentrations of metals in vegetables of tarragon, Bay laurel, dill, Syrian mesquite, vine leaves, thymes, arugula, basil, common purslane and parsley of this study were found to be in the range of, 76-778 for Al, 10-333 for B, 4-119 for Ba, 2812-24645 for Ca, 0.1-0.32 for Co, 201-464 for Fe, 3661-46400 for K, 0.31–1.53 for Li, 860-14330 for Mg, 16.20-71.5 for Mn, 612-4725 for Na and 15.8-46 µg g-1 for Zn. The results revealed that the concentration of Al, B except in Syrian mesquite, Ba, Ca, Fe, K, Mg and Mn in all analysed vegetables is higher than the recommended value, Li is well-within the safe limit, and Co, Na except in dill, arugula and common purslane, Zn are lower than the recommended intake of these elements. From health point of view, the HQ values for Al, Fe (for all vegetables) and Ba (in dill, vine leaves, thymes, arugula, basil, common purslane and parsley) were higher than one, indicating potential non-cancer health risk due to exposure to these metals. Furthermore, the HI value for all vegetables was higher than one, indicating potential non-cancer health risk due to long-term exposure to these metals.
Mefenamic acid belongs to non-steroidal anti-inflammatory drugs that are used widely for the treatment of analgesia. Our aim from this study is to establish a new assay for the quantitative determination of mefenamic acid (MFA) in the pharmaceutical sample by two sensitive and rapid flow injection-fluorometric methods. A homemade fluorometer was used in fluorescence measurements, which using solid-state laser diode 405 and 532 nm as a source, combined with a continuous flow injection technique. The first method depends on the effect of MFA on calcein blue (CLB) fluorescence at 405 nm. Another method is a study of rhodamine-6G (Rh-6G) fluorescence after adding MFA, and recording at 532 nm. Optimum parameters as fluorescent dye concen
... Show MoreAlterations of trace element concentrations adversely affect biological processes and could promote carcinogenesis. Trace element deficiency or excess is implicated in the development or progression of some cancers like colorectal cancer. The aim of the present study was to compare the serum copper (Cu) and zinc (Zn) concentrations in patients with colorectal cancer from Iraqi male patient with those of healthy subjects. During the period of March 2015 until august 2015, a total of 25 patients with metastatic colon cancer and 20 healthy volunteers were enrolled from the Al-Kadhimia Teaching Hospital after the diagnosis using a histopathological examination for the malignant tumor; their age was between (38-60) years. Higher
... Show More
The varied applications of polystyrene in various fields of life led to examining the cause of radiation influence on some rheological behavior of commercial Polystyrene (PS) solution in the chloroform (CHCl3) solvent. Polystyrene grains shape samples were irradiated using the radioactive element Cesium- 137 with (9 µci) activity for 10, 20, and 30 minutes. The viscosity of the polymer solution depends on the concentration and size (i.e. molecular weight) of the dissolved polymer. Experimental data showed that the radiation dose affected the value of viscosity (shear, relative, specific, and reduced). The viscosity value significantly reduced at 10 min radiation dose and when increasing the dose, the viscosity value increased
... Show MoreThe aim of this study is to evaluate the levels of trace elements Magnesium (Mg), Zinc (Zn), Copper (Cu), and Selenium (Se) in blood sera of asthmatic patients by Atomic Absorption Spectrophotometry (AAS). The concentrations of Mg, Cu, and Zn have been determined by Flame Atomic Absorption spectrophotometry (FAAS), and Se with flameless Graphite Furnace Atomic Absorption Spectrophotometry (GFAAS). The study involves (55) asthmatic patients as study group and (28) subjects as control from both genders. Serum levels of Mg, Cu, and Se were significantly higher (p<0.001 for all) in patients when compared with healthy subjects, while Zn level was relatively significant (p<0.05). Our observations confirm the efficacy and applicability of (AAS) in
... Show MoreTwo simple methods spectrophotometric were suggested for the determination of Cefixime (CFX) in pure form and pharmaceutical preparation. The first method is based without cloud point (CPE) on diazotization of the Cefixime drug by sodium nitrite at 5Cº followed by coupling with ortho nitro phenol in basic medium to form orange colour. The product was stabilized and measured 400 nm. Beer’s law was obeyed in the concentration range of (10-160) μg∙mL-1 Sandell’s sensitivity was 0.0888μg∙cm-1, the detection limit was 0.07896μg∙mL-1, and the limit of Quantitation was 0.085389μg∙mL-1.The second method was cloud point extraction (CPE) with using Trtion X-114 as surfactant. Beer
... Show MoreOtitis media with effusion (OME) is a common disease especially among young children (before school age) and it is one of the common causes of acquired hearing loss in childhood. Pediatric patients with OME are usually undernourished. The purpose of this study is to determine whether the serum levels of trace elements (zinc, copper, magnesium, iron) have a role in the development of OME in children. This study carried out on 55 children and subdivided them into two groups. Group 1 (patient group) consist of 30 children suffering from OME and group 2 (control group) included 25 apparently healthy children. Serum levels of zinc, copper, magnesium and iron were measured for both groups. Comparison the results between the two groups showed t
... Show MoreIn this paper, the reliability and scheduling of maintenance of some medical devices were estimated by one variable, the time variable (failure times) on the assumption that the time variable for all devices has the same distribution as (Weibull distribution.
The method of estimating the distribution parameters for each device was the OLS method.
The main objective of this research is to determine the optimal time for preventive maintenance of medical devices. Two methods were adopted to estimate the optimal time of preventive maintenance. The first method depends on the maintenance schedule by relying on information on the cost of maintenance and the cost of stopping work and acc
... Show MoreThe current study sheds light on the measurement and estimation of the radioactivity of radionuclides (238U, 226Ra, 232Th, and 40k) in natural waters of different regions of Nineveh Governorate in Iraq.15 samples were collected from different sources of natural waters, where gamma-ray spectroscopy was used using NaI)TI) sodium iodide detector to determine the concentration of radioactivity in the samples. According to the results, the radioactivity concentration in the tested water sample were ranged from 0.36 ± 0.04-1.57 ± 0.09with an average value of 0.69 ± 0.06 Bq/l for 238U, and 2.9 ± 0.02-0.88 ± 0.03 with an average value of 0.65 ± 0.03 Bq/l for 226Ra Bq/l
... Show MoreObjective- the study aim to determine the cardiac patient knowledge about anticoagulant medications using and its relationship with demographic data(age. gender. level of education. occupational). Methodology- A descriptive study(quasi-experimental)design was carried out to determine cardiac patient knowledge consider to using anticoagulant medications . Starting from(1th Jun 2017 to5th October 2018).To achieve the objectives of the study, a non-probability sample (a purposive sample) consisted of random sample comprised of (30) patients were taken anticoagulant medications ..The measurement of patient knowledge were collected through the use of questionnaire which is related to patient knowledge toward using the anticoagulant medication
... Show MoreThe proliferation of cellular network enabled users through various positioning tools to track locations, location information is being continuously captured from mobile phones, created a prototype that enables detected location based on using the two invariant models for Global Systems for Mobile (GSM) and Universal Mobile Telecommunications System (UMTS). The smartphone application on an Android platform applies the location sensing run as a background process and the localization method is based on cell phones. The proposed application is associated with remote server and used to track a smartphone without permissions and internet. Mobile stored data location information in the database (SQLite), then transfer it into location AP
... Show More