Preferred Language
Articles
/
bsj-679
Gel clot assay used for detection of candida spp onfection in urinary tract
...Show More Authors

the study including isolation and identification of candida spp causing UTIs from patintes coming to al-yarmouk hospital

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Feb 01 2014
Journal Name
World Journal Of Pharmaceutical Sciences
Detection of JAK2V617F Mutation and Serum Levels of Alkaline Phosphatase and Lactate Dehydrogenase in Chronic Myelogenous Leukemia.
...Show More Authors

Chronic myelogenous leukemia (CML) is a myeloproliferative neoplasm arises from Bcr-Abl gene translocation (called Ph chromosome) in hematopoietic stem cells (HSCs). This genetic abnormality results in constitutive activation of tyrosine kinase and subsequent uncontrol growth and multiplication of granulocytes. The cornerstone in treatment of CML are tyrosine kinase inhibitors, of which imatinib is the most effectively used. JAK2V617F mutation is an acquired single nucleotide polymorphism (SNP) occurs in JAK2 gene and is associated with many hematological malignancy other than CML. It was thought that the two genetic abnormalities (Bcr-Abl and JAK2V617F) occur mutually; however, growing body of evidences suggested the reverse. This study a

... Show More
Preview PDF
Publication Date
Fri Dec 01 2017
Journal Name
Rawaa Emad Jaloud And Fadia Falahfadia Falah
Isolation and Identification of Fungal Propagation in Iraqi Meat and Detection of Aflatoxin B1 Using ELISA Technique
...Show More Authors

Scopus (5)
Scopus
Publication Date
Wed Jan 01 2025
Journal Name
Kuwait Journal Of Science
Detection of the most frequent sources of dust storms in Iraq during 2020–2023 using space tools
...Show More Authors

Dust storms are typical in arid and semi-arid regions such as the Middle East; the frequency and severity of dust storms have grown dramatically in Iraq in recent years. This paper identifies the dust storm sources in Iraq using remotely sensed data from Meteosat-spinning enhanced visible and infrared imager (SEVIRI) bands. Extracted combined satellite images and simulated frontal dust storm trajectories, using the Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) model, are used to identify the most influential sources in the Middle East and Iraq. Out of 132 dust storms in Iraq during 2020–2023, the most frequent occurred in the spring and summer. A dust source frequency percentage map (DSFPM) is generated using ArcGIS so

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Wed Apr 02 2014
Journal Name
Journal Of Theoretical And Applied Information Technology
TUMOR BRAIN DETECTION THROUGH MR IMAGES: A REVIEW OF LITERATURE
...Show More Authors

Today’s modern medical imaging research faces the challenge of detecting brain tumor through Magnetic Resonance Images (MRI). Normally, to produce images of soft tissue of human body, MRI images are used by experts. It is used for analysis of human organs to replace surgery. For brain tumor detection, image segmentation is required. For this purpose, the brain is partitioned into two distinct regions. This is considered to be one of the most important but difficult part of the process of detecting brain tumor. Hence, it is highly necessary that segmentation of the MRI images must be done accurately before asking the computer to do the exact diagnosis. Earlier, a variety of algorithms were developed for segmentation of MRI images by usin

... Show More
Scopus (48)
Scopus
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Engineering
Detection and Diagnosis of Induction Motor Faults by Intelligent Techniques
...Show More Authors

This paper presents a complete design and implementation of a monitoring system for the operation of the three-phase induction motors. This system is built using a personal computer and  two types of sensors (current, vibration) to detect some of the mechanical faults that may occur in the motor. The study and examination of several types of faults including (ball bearing and shaft misalignment faults) have been done through the extraction of fault data by using fast Fourier transform (FFT) technique. Results showed that the motor current signature analysis (MCSA) technique, and measurement of vibration technique have high possibility in the detection and diagnosis of most mechanical faults with high accuracy. Subsequently, diagnosi

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 28 2018
Journal Name
Indian Journal Of Natural Sciences
Detection of the Main Mycotoxins in Feed of Horses in Al-Zawra'a Park and Study their Effects on Hematological Feature
...Show More Authors

Preview PDF
Publication Date
Tue May 23 2023
Journal Name
Journal Of Engineering
Enhancement of the Detection of the TCP SYN Flooding (DDoS) Attack
...Show More Authors

The major of DDoS attacks use TCP protocol and the TCP SYN flooding attack is the most common one among them. The SYN Cookie mechanism is used to defend against the TCP SYN flooding attack. It is an effective defense, but it has a disadvantage of high calculations and it doesn’t differentiate spoofed packets from legitimate packets. Therefore, filtering the spoofed packet can effectively enhance the SYN Cookie activity. Hop Count Filtering (HCF) is another mechanism used at the server side to filter spoofed packets. This mechanism has a drawback of being not a perfect and final solution in defending against the TCP SYN flooding attack. An enhanced mechanism of Integrating and combining the SYN Cookie with Hop Count Filtering (HCF) mech

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
Automated breast ultrasound: A comparison study with handheld ultrasound in detection and characterization of lesions in mammographically dense breast
...Show More Authors

Background: Although mammography is a powerful screening tool in detection of early breast cancer, it is imperfect, particularly for women with dense breast, which have a higher risk to develop cancer and decrease the sensitivity of mammogram, Automated breast ultrasound is a recently introduced ultrasonography technique, developed with the purpose to standardize breast ultrasonography and overcome some limitations of handheld ultrasound, this study aims to evaluate the diagnostic efficacy of Automated breast ultrasound and compare it with handheld ultrasound in the detection and characterization of breast lesions in women with dense breasts. Objectives: To evaluate the diagnostic efficacy of Automated breast ultrasound and compare

... Show More
Crossref (1)
Crossref
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
Automated breast ultrasound: A comparison study with handheld ultrasound in detection and characterization of lesions in mammographically dense breast
...Show More Authors

Background: Although mammography is a powerful screening tool in detection of early breast cancer, it is imperfect, particularly for women with dense breast, which have a higher risk to develop cancer and decrease the sensitivity of mammogram, Automated breast ultrasound is a recently introduced ultrasonography technique, developed with the purpose to standardize breast ultrasonography and overcome some limitations of handheld ultrasound, this study aims to evaluate the diagnostic efficacy of Automated breast ultrasound and compare it with handheld ultrasound in the detection and characterization of breast lesions in women with dense breasts.

Objectives:<

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Apr 30 2023
Journal Name
Al-kindy College Medical Journal
Comparison between Quantitative Computed Tomography and Dual-Energy X-Ray Absorptiometry in the Detection of Osteoporosis in Postmenopausal Women
...Show More Authors

Background: Osteoporosis is denoted by low bone mass and microarchitectural breakdown of bone tissue, directing to increased fracture risk and bone fragility. Fractures may lead to a decreased quality of life and increased medical costs. Thus, osteoporosis is widely considered a significant health concern.

Objective. This study aimed to compare quantitative computed tomography (QCT) and dual-energy X-Ray absorptiometry (DXA) to detect osteoporosis in postmenopausal women.

Subjects and Methods. We measured spinal volumetric bone mineral density (BMD) with QCT and areal spinal and hip BMD with DXA in 164 postmenopausal women. We calculated the osteo

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (2)
Scopus Crossref