Chromatographic and spectrophotometric methods for the estimation of mebendazole in
pharmaceutical products were developed. The flow injection method was based on the oxidation of
mebendazole by a known excess of sodium hypochlorite at pH=9.5. The excess sodium hypochlorite is then
reacted with chloranilic acid (CAA) to bleach out its color. The absorbance of the excess CAA was recorded
at 530 nm. The method is fast, simple, selective, and sensitive. The chromatographic method was carried out
on a Varian C18 column. The mobile phase was a mixture of acetonitrile (ACN), methanol (MeOH), water
and triethylamine (TEA), (56% ACN, 20% MeOH, 23.5% H2O, 0.5% TEA, v/v), adjusted to pH = 3.0 with
1.0 M hydrochloric acid. Naphazoline nitrate was used as an internal standard. The absorption of mebendazole
was measured using a variable wavelength UV detector at 290 nm. Linearity was obtained in the concentration
range of 1-60 and 0.10-3.0 mg/L for the HPLC and FIA, respectively. The methods were applied successfully
for the assay of mebendazole in pharmaceutical products and no interferences were observed from the common
excipients usually used. The proposed methods were validated for their accuracy and precision.
In this research, salbutamol sulphate (SAS) has been determined by a simple, rapid and sensitive spectrophotometric method. Salbutamol sulphate in this method is based on the coupling of SAS with diazotized ρ- bromoaniline reagent in alkaline medium of Triton X-100 (Tx) to form an orange azo dye which is stable and water-soluble. The azo dye is exhibiting maximum absorption at 441 nm. A 10 - 800 µg of SAS is obeyed of Beer's law in a final volume of 20 ml, i.e., 0.5- 40 ppm with ε, the molar absorptivity of 48558 L.mol-1.cm-1 and Sandell's sensitivity index of 0.01188 µg.cm-2. This new method does not need solvent extraction or temperature control which is well applied to determine SAS in d
... Show MoreSimple and sensitive batch and Flow-injection spectrophotometric methods for the determination of Procaine HCl in pure form and in injections were proposed. These methods were based on a diazotization reaction of procaine HCl with sodium nitrite and hydrochloric acid to form diazonium salt, which is coupled with chromatropic acid in alkaline medium to form an intense pink water-soluble dye that is stable and has a maximum absorption at 508 nm. A graphs of absorbance versus concentration show that Beer’s law is obeyed over the concentration range of 1-40 and 5-400 µg.ml-1 of Procaine HCl, with detection limits of 0.874 and 3.75 µg.ml-1 of Procaine HCl for batch and FIA methods respectively. The FIA average sample throughput was 70 h-1. A
... Show MoreA simple, accurate and sensitive spectrophotometric method for the determination of Procaine penicillin (PP) is described. The method is based on charge-transfer reaction of PP with metol (N-methyl-p-hydroxy aniline) in the presence of ferric sulphate to form a purple-water soluble complex ,which is stable and has a maximum absorption at 510 nm .A graph of absorbance versus concentration shows that Beer’s low is obeyed over the concentration range of 3-80 µg /ml of PP (i.e.,3-80 ppm) with a molar absorbativity of 4.945 ×103 L.mol-1.cm-1 ,Sandell sensitivity of 0.1190 µg cm-2 ,a relative error of (-1.57)-2.79 % and a standard deviation of less than 0.59 depending on the concentration of PP.The optimum conditions for full co
... Show MoreA simple indirect spectrophotometric method for determination of mebendazol in pure and pharmaceutical formulation was presented in this study. UV-Visible spectrophotometry using the optimal conditions was developed for determination of mebendazole in pure drug and different preparation samples. The method is based on the oxidation of drug by nbromosuccinimide with hydrochloric acid and the left amount of oxidizing agent was determined by the reaction with tartarazine and the absorbance was measured at 428 nm. Calibration curves were linear in the range of 5 to 30 µg.mL-1 with molar absorptivity 8437.2 L.mol-1 .cm-1 . The limits of detection and quantification were determined and found to be 0.7770 µg.mL-1 and 2.3400 µg.mL-1 respec
... Show MoreDetermining the actual amounts of active ingredients in various pharmaceutical commercial forms is still receiving a lot of attention. Two flow injection analysis (FIA) methods were suggested for determination of mesalazine (MES) in pharmaceutical forms. Normal and reverse FIA systems (nFIA and rFIA) combined with UV-Vis spectrophotometric technique were used for the analysis. The methods involved using two mods of FIA systems for measuring a colored product result from coupling of MES with 2,2'-dihydroxybiphenyl after oxidized with sodium periodate in alkaline medium. The absorbance of the red colored dye was measured at maximum wavelength of 500 nm. The calibration graphs for MES were linear in the ranges 2.5-200 and 0.5-60 µg/mL with
... Show MoreThis research involves an indirect Fluorophotometric method for the determination of microgram amount of oxymetazoline hydrochloride in the concentration range 0.1-5.0 g/ml. The method is based on the oxidation of the drug by cerium sulphate solution which is acidic medium where Ce IV is reduced to Ce III which can be excited at 259 nm to give an emitted light at 377 nm which is directly proportional to the concentration of Ce III which is equivalent to Ce IV that is needed to oxidize the studied drug. The average recovery of the method is 100.19% and relative standard deviation (RSD) < 0.37% . The method have been successfully applied to the determination of the studied drug in its pure and pharmaceutical preparations and it wa
... Show MoreA new spectrophotometric flow injection method has been establish for the determintaions of some catecholaminedrugs
Simple and sensitive kinetic methods are developed for the determination of Paracetamol in pure form and in pharmaceutical preparations. The methods are based on direct reaction (oxidative-coupling reaction) of Paracetamol with o-cresol in the presence of sodium periodate in alkaline medium, to form an intense blue-water-soluble dye that is stable at room temperature, and was followed spectrophotometriclly at λmax= 612 nm. The reaction was studied kinetically by Initial rate and fixed time (at 25 minutes) methods, and the optimization of conditions were fixed. The calibration graphs for drug determination were linear in the concentration ranges (1-7 μg.ml-1) for the initial rate and (1-10 μg.ml-1) for the fixed time methods at 25 min.
... Show MoreGenistein (GEN) is The major isoflavone found in soybeans, has a number of cardiovascular health benefits, Postmenopausal syndrome and osteoporosis. A direct flow injection analysis method for estimation of (GEN) in pure and supplements formulation . This system is based on diazotization coupling reactions between procaine penciline (PR) and genistein in basic medium, they formed yellow dyes have maximum absorption at 416 nm. Calibration curve were constructed over different GEN concentrations, linearity for GEN was 10-100 µg.mL-1 and detection limits of 1.51 ?g/mL. In the FIA technique, all analytical factors were analyzed and optimized. The established method was successfully used to determine GEN in the formulations of its supplement
... Show MoreThe aim of this work was to develop and validate a rapid and low cost method for estimation of ibuprofen in pharmaceutical suspensions using Reverse-Phase High Performance Liquid Chromatography. The proposed method was conducted and validated according to International Conference on Harmonization (ICH) requirements. The chromatographic parameters were as follows: column of octyldecylsilyl C18 with dimensions (150 × 4.6) mm, mobile phase composed of acetonitrile with phosphoric acid with a ratio of 50 to 50 each using isocratic mode, flow rate of 1.5 mL/min and injection volume of 5 μL. The detection was carried out using UV detector at 220 nm. The method was validated and showed short retention time for ibuprofen peak at 7.651 min, wit
... Show More