Most recent studies have focused on using modern intelligent techniques spatially, such as those
developed in the Intruder Detection Module (IDS). Such techniques have been built based on modern
artificial intelligence-based modules. Those modules act like a human brain. Thus, they should have had the
ability to learn and recognize what they had learned. The importance of developing such systems came after
the requests of customers and establishments to preserve their properties and avoid intruders’ damage. This
would be provided by an intelligent module that ensures the correct alarm. Thus, an interior visual intruder
detection module depending on Multi-Connect Architecture Associative Memory (MCA) has been proposed.
Via using the MCA associative memory as a new trend, the proposed module goes through two phases: the
first is the training phase (which is executed once during the module installation process) and the second is
the analysis phase. Both phases will be developed through the use of MCA, each according to its process.
The training phase will take place through the learning phase of MCA, while the analysis phase will take
place through the convergence phase of MCA. The use of MCA increases the efficiency of the training
process for the proposed system by using a minimum number of training images that do not exceed 10
training images of the total number of frames in JPG format. The proposed module has been evaluated using
11,825 images that have been extracted from 11 tested videos. As a result, the module can detect the intruder
with an accuracy ratio in the range of 97%–100%. The average training process time for the training videos
was in the range of 10.2 s to 23.2 s.
In this paper a theoretical attempt is made to determine whether changes in the aorta diameter at different location along the aorta can be detected by brachial artery measurement. The aorta is divided into six main parts, each part with 4 lumps of 0.018m length. It is assumed that a desired section of the aorta has a radius change of 100,200, 500%. The results show that there is a significant change for part 2 (lumps 5-8) from the other parts. This indicates that the nearest position to the artery gives the significant change in the artery wave pressure while other parts of the aorta have a small effect.
The main target of the current study is to investigate the microbial content and mineral contaminants of the imported meat available in the city of Baghdad and to ensure that it is free from harmful bacteria, safe and it compliances with the Iraqi standard specifications. Some trace mineral elements such as (Iron, Copper, Lead, and Cadmium) were also estimated, where 10 brands of these meats were collected. Bacteriological tests were carried out which included (total bacterial count,
Early and accurate detection of COVID-19 from chest computed tomography (CT) scans are becoming essential for effective clinical decision-making and disease control. This study is proposing a robust deep learning framework that integrates a convolutional self-attention network (CSAN), gamma correction for image enhancement, and a voting-based ensemble classifier to improving diagnostic performance. The model is being evaluated on a dataset of 2,271 CT images and is achieving an accuracy of 95.12%, sensitivity of 97.25%, specificity of 98.11%, F1-score of 96.46%, and area under the curve (AUC) of 0.977. Experimental results are demonstrating that the proposed method significantly surpasses baseline models, including standalone CSAN,
... Show MoreEchocardiography is a widely used imaging technique to examine various cardiac functions, especially to detect the left ventricular wall motion abnormality. Unfortunately the quality of echocardiograph images and complexities of underlying motion captured, makes it difficult for an in-experienced physicians/ radiologist to describe the motion abnormalities in a crisp way, leading to possible errors in diagnosis. In this study, we present a method to analyze left ventricular wall motion, by using optical flow to estimate velocities of the left ventricular wall segments and find relation between these segments motion. The proposed method will be able to present real clinical help to verify the left ventricular wall motion diagnosis.
In the early 90s military operations and United Nations Special Commission “UNSCOM” teams have been destroyed the past Iraqi chemical program. Both operations led an extensive number of scattered remnants of contaminated areas. The quantities of hazardous materials, incomplete destructed materials, and toxic chemicals were sealed in two bunkers. Deficiency of appropriate destruction technology led to spreading the contamination around the storage site. This paper aims to introduce the environmental detection of the contamination in the storage site area using geospatial analysis technique. The environmental contamination level of nutrients and major ions such as sulphate (SO4), potassium (K), sodium (Na), magnesi
... Show MoreGraphene oxide (GO) was prepared from graphite (GT) with Hammer method, the GO was reduced with hydrazine hydrate to produce a reduced graphene oxide (RGO). The RGO was reacted with thiocarbohydrazide (TCH) to functionalize the RGO with 4-amino-3-symbol-1h-1, 2, 4-triazol-5 (4H) –thion group and to obtain (RGOT). All the prepared nanomaterial and the product of the functionalization RGOT were characterized with Fourier transformer infrared (FT-IR) spectroscopy, X-ray diffraction (XRD) analysis. RGOT mixed with ultrasonic device at different pH values of phosphate buffer solution (PBS), the mixture used to modifying a screen printed carbon electrodes SPCE and with cyclic voltammetry the sensitivity of selectivity of the new modifying elect
... Show MoreBegomoviruses infecting zucchini squash were investigated. Leaf samples were collected from zucchini squash growing areas in Baghdad (Jhadryaa and Yusufiyah), Babylon (Jibela and Mahmudiyah) and Diyala (Khan Bani Saad) Provinces. Samples were screened for the presence of begomoviruses using polymerase chain reaction (PCR) and Deng genus specific primers. Sixteen out of 40 samples were begomovirus positive. Sequence analysis confirmed the detection of Tomato leaf curl Palampur virus (TLCPALV)