In an intensive study of the various species of the Euglenophyceae under different environmental conditions, the algal samples were collected monthly in twelve springs and six related streams from September 2019 to August 2020 within Shaglawa district-Erbil Province in virgin areas for phycolimnological study. Twenty species of Euglenophyceaen are identified as a new record for the algal flora. These taxa consist of Colacium vesiculosum, Lepocinclis salina and L.wangi, Eutreptia viridis, Euglena chlamydophora, E. clavata, E. geniculata, E. intermedia var klebsii, E. limnophila, E. oblonga, E. sociabilis, E. stellate and E. variabilis, Peranema sacculus, Phacus circumflexus, Ph. dangeardii, Ph. peteloti, Petalomonas mediocanella var disomata, Trachelomonas manginii, and T. volvocina var derephora. All of these new records are described and illustrated as much as possible. According to physicals and chemicals characteristics, water temperature varied from 14.942˚C to 18.475˚C, pH lies on alkaline side of neutrality, electrical conductivity ranged between (627.472-2092.306µs/cm) and high concentration of salinity recorded in Azarian spring.
A new Turbidimetric method characterized by simplicity, accuracy and speed for determination of iron(III) in drug samples by continuous flow injection analysis. The method was based on the formation of complex for iron(III) with 8-hydroxyquinoline in presence of ammonium acetate as a medium for the formation of deep green precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.6 mL.min-1 flow rate using H2O as a carrier, 1.9 mL.min-1 (14 mmol.L-1) ammonium acetate, 2.4 mL.min-1 (14 mmol.L-1) 8-hydroxyquinoline, 60 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.1-8.0 mmol.L-1
... Show MoreA newly developed analytical method characterized by its speed and sensitivity for the determination of metoclopramide hydrochloride (MCP-HCl) in pure and pharmaceutical preparation via turbidimetric measurement (0-180o) by Ayah 6SX1-T-2D Solar cell-CFI Analyser. The method was based on the reaction of phosphomolybdic acid with metoclopramide hydrochloride in acidic medium to form yellowish white precipitate for the ion-pair complex. Turbidity was measured via the reflection of incident light that collides on the surface precipitated particles at 0-180o. Chemical and physical parameters were studied and optimized. The calibration graph was linear in the range of 0.0005-3 or 0.0005- 4 mMol.L-1, with correlation coefficient r = 0.9947&
... Show MoreThe current study is based on previous findings, where corporate governance (CG) significantly increased corporate social responsibility (CSR) to enhance transparency while reducing the tendency of corporate management to engage in earnings management (EM). A sample of 11 Iraqi banks listed on the Iraq Stock Exchange from 2010 to 2020 was selected. The CG was included in the board size and board independence apart from the variables of Chief Executive Officer (CEOs) gender, majority shareholder ownership, foreign ownership, and institutional ownership. The CSR included the wage growth rate, bank contribution growth rate for social security, training programmes, subsidies, environmental protection, and bank compliance with the law. Specifica
... Show MoreThe water quality index was used for the evaluation of the quality of water, as well its impacts on the rotifer abundance, in the Tigris River as it passes through Mishahda City, northern Baghdad. Five sites were selected and samples were collected during October 2019 to September 2020. It was noticed that the index values in most sites have exceeded the upper limits of river waters. The values ranged from 40 (Poor) to 45 (Marginal) in all sites. While, the values were from 42 (Poor) to 65 (Fair) during different seasons. As for drinking usages, the results demonstrated poor or undrinkable (31-40) water in all sites. Meanwhile, the values ranged from 39 (Poor) to 56 (Clear) in regard to seasons. The index values
... Show MoreA new turbidimetric-flow injection method is described for the determination of chlorpromazine HCl in pure and pharmaceutical preparation. The method is characterized by simplicity, sensitivity and fast, it is based on formation of ion pair compound between chlorpromazine HCl and Potassium hexacyanoferrate(III) in an acid medium for the formation of greenish yellow precipitate. This precipitate was determined using homemade Linear Array Ayah 5SX1-T-1D continuous flow injection analyser. Optimum concentrations of chemical reactants, physical instrumental conditions have been investigated. The linear dynamic range of chlorpromazine HCl was 3-30 mmol.L-1 while correlation coefficient (r) was 0.9929 and percentage linearity (%r2) C.O.D was 9
... Show MoreA new ligand [ 2-chloro-N- (1,5-dimethyl-3-oxo-2-phenyl-2,3-dihydro -1H-pyrazol- 4-ylcarbamothioyl)acetamide](L) was synthesized by reacting the Chloro acetyl isothiocyanate with 4-aminoantipyrine,The ligand was characterized by(C HNS) elemental microanalysis and the spectral measurements including Uv-Vis ,IR ,1H and13C NMR spectra, some transition metals complex of this ligand were prepared and characterized by Uv-Vis, FT-IR spectra, conductivity measurements, magnetic susceptibility and atomic absorption. From the obtained results the molecular formula of all prepared complexes were [M(L)2(H2O)2]Cl2 (M+2 =Mn, Co, Ni, Cu, Zn, Cd and Hg),the proposed geometrical structure for all complexes were octahedral.
A simple, sensitive and rapid method was used for the estimate of: Propranolol with Bi (III) to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on a reaction between propranolol and Bi (III) in an aqueous medium to obtain a yellow precipitate. Optimum parameters were studied to increase the sensitivity for the developed method. A linear range for calibration graph was 0.1-25 mmol/L for cell A and 1-40 mmol/L for cell B, and LOD 51.8698 ng/200 µL and 363.0886 ng /200 µL , respectively to cell A and cell B with correlation coefficient (r) 0.9975 for cell A, 0.9966 for cell B, RSD% was lower than 1%, (n = 8) for the
... Show More