Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at threshold 10%. The DD/DTA criteria are performed with 3%/3 mm and 2%/2 mm. A significant difference is shown between the measured and calculated point dose for the treatment plans. A comparison made between the gamma passing rate between the 2%/2 mm and 3%/3 mm shows a significant difference for local and global which shows that the 2%/2 mm are more sensitive to dose variation than 3%/3 mm. The total monitor unit (MU) shows a negative linear relationship with both criteria and %GP types. A significant correlation is shown between the total MU and global %GP at 2%/2 mm criterion. The conclusion of the study indicates that 2%/2 mm criterion is more sensitive to the dose distribution changes than the 3%/3 mm. The total number of monitor units should be taken into consideration during the planning of H&N tumors using the IMRT plans.
In this paper, an experimental study was conducted to enhance the thermal performance of a double-pass solar air heater (SAH) using phase change material (PCM) for thermal storage at climatic conditions of Baghdad city - Iraq. The double-pass solar air heater integrated with thermal storage system was manufactured and tested to ensure that the air heating reserved after the absence of the sun. The rectangular cavity filled with paraffin wax was used as a latent heat storage and incorporated into the lower channel of solar air heater. Experiments were carried out to evaluate the charging and discharging characteristics of two similar designed solar air collectors with and without using phase change material at a constant
... Show More60 patients diagnosed as having urticaria were included in the study ; 30 patients were effected with acute urticaria and 30 patients were affected with chronic urticaria. In addition, 30 healthy adult volunteers were selected as control group .The patients and control groups sera were examined with enzyme linked immunosorbent assay ( ELISA) to detect total level IgE and radial immunodiffusion (RID) to detect levels of IgG , IgA and IgM . The total level of IgE in acute urticaria ( 1.45±0.13) IU/mL and chronic urticaria (2.12 ± 0.10) IU/mL patients were significantly higher than the control groups ( 0.85 ± 0.10)IU/mL (p<0.05). The level of IgG in acute urticaria ( 12.5± 0.42) g/L and chronic (13.16±0.40) g/L patients , IgA in acute (2.
... Show MorePurpose This study investigated periodontal ligament (PDL) restoration in osseointegrated implants using stem cells. Methods Commercial pure titanium and zirconium oxide (zirconia) were coated with beta-tricalcium phosphate (β-TCP) using a long-pulse Nd:YAG laser (1,064 nm). Isolated bone marrow mesenchymal cells (BMMSCs) from rabbit tibia and femur, isolated PDL stem cells (PDLSCs) from the lower right incisor, and co-cultured BMMSCs and PDLSCs were tested for periostin markers using an immunofluorescent assay. Implants with 3D-engineered tissue were implanted into the lower right central incisors after extraction from rabbits. Forty implants (Ti or zirconia) were subdivided according to the duration of implantation (healing period: 45 o
... Show MoreIn this work an experimental study is performed to evaluate the thermal performance
of locally made closed loop solar hot water system using a shell and helical coiled tube
heat exchanger as a storage tank. Several measurements are taken include inlet and outlet
temperatures of both collectors and supply water and temperature distribution within the
storage tank. This is beside the water flow rate in both collectors and load cycle. The
main parameters of the system are obtained.
خلفية البحث: مرض السكري هو عامل خطر لأمراض القلب والأوعية الدموية وتصلب الشرايين وسبب مهم للوفاة. يرتبط خلل الدهون في الدم بشكل شائع بمرض السكري من النوع الثاني ويعتبر مؤشر تصلب الشرايين في البلازما علامة قوية للتنبؤ بخطر الإصابة بتصلب الشرايين وأمراض القلب التاجية. الهدف من البحث: دراسة ارتباط المؤشرات الدهنية لتصلب الشرايين لدى المرضى العراقيين المصابين بالسكري من النوع الثاني ولديهم أمراض قلبية وعائ
... Show MoreThis study focused on the synthesis of novel polymers incorporating the 1,3,4-oxadiazole ring. Four polymers were specifically prepared by blending polymers (6-9) with polyvinyl alcohol (PVA) in defined ratios, resulting in the formation of blended polymers (10-13). The synthesized polymers were characterized using Fourier Transform Infrared (FTIR) spectroscopy and proton nuclear magnetic resonance (1H-NMR). The results showed that the structure aligned with the proposed synthetic polymers. Furthermore, the physical and thermal properties were studied using scanning electron microscopy (SEM), thermogravimetric analysis (TGA) and Differential Scanning Calorimetry (DSC). Additionally, the biological activity was examined against two s
... Show MoreIn this paper, a compartmental differential epidemic model of COVID-19 pandemic transmission is constructed and analyzed that accounts for the effects of media coverage. The model can be categorized into eight distinct divisions: susceptible individuals, exposed individuals, quarantine class, infected individuals, isolated class, infectious material in the environment, media coverage, and recovered individuals. The qualitative analysis of the model indicates that the disease-free equilibrium point is asymptotically stable when the basic reproduction number R0 is less than one. Conversely, the endemic equilibrium is globally asymptotically stable when R0 is bigger than one. In addition, a sensitivity analysis is conducted to determine which
... Show MoreType 2 diabetes mellitus(T2DM) is a metabolic disease that is associated with an increased risk for atherosclerosis by 2-4 folds than in non- diabetics. In general population, low IGF-1 has been associated with higher prevalence of cardiovascular disease and mortality .This study aims to find out the relationship between IGF-1 level and other biochemical markers such as Homeostasis Model Assessment insulin resistance(HOMAIR) and Body Mass Index(BMI) in type 2 diabetic patients . This study includes (82) patients (40 females and 42 males) with age range (40-75) years,(34) non obese diabetic patients and (48) obese diabetic patients. The non obese individuals considered
... Show More