Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at threshold 10%. The DD/DTA criteria are performed with 3%/3 mm and 2%/2 mm. A significant difference is shown between the measured and calculated point dose for the treatment plans. A comparison made between the gamma passing rate between the 2%/2 mm and 3%/3 mm shows a significant difference for local and global which shows that the 2%/2 mm are more sensitive to dose variation than 3%/3 mm. The total monitor unit (MU) shows a negative linear relationship with both criteria and %GP types. A significant correlation is shown between the total MU and global %GP at 2%/2 mm criterion. The conclusion of the study indicates that 2%/2 mm criterion is more sensitive to the dose distribution changes than the 3%/3 mm. The total number of monitor units should be taken into consideration during the planning of H&N tumors using the IMRT plans.
FG Mohammed, HM Al-Dabbas, Iraqi journal of science, 2018 - Cited by 6
Nigella sativa has various pharmacological properties and has been used throughout history for a variety of reasons. However, there is limited data about the effects of N. sativa (NS) on human cancer cells. This study aimed at observing the roles of methanolic extract of N. sativa on apoptosis and autophagy pathway in the Human PC3 (prostate cancer) cell line. The cell viability was checked by MTT assay. Clonogenic assay was performed to demonstrate clonogenicity and Western blot was used to check caspase-3, TIGAR, p53, and LC3 protein expression. The results demonstrated that PC3 cell proliferation was inhibited, caspase-3 and p53 protein expression was induced, and LC3 protein expression was modulated. The clonogenic assay showed that PC3
... Show MoreIntroduction. Tangential gunshot wounds (TGSW) to the head is the high-velocity bullet that does not penetrate the cranium but passes through the tissue adjoining the cranial cavity, creating a “gutter” wound and indirectly causing cerebral injury. This article presents a reporting case of TGSW to the head, discusses the mechanism underlying this traumatic injury and the possible complications resulting from it, and reviews of literature. Case description. A thirteen-year-old schoolboy was admitted to the emergency department (ER) of the neurosurgery teaching hospital in Baghdad, Iraq, with a tangential gunshot to the head of an unknown source during civilian protests in Baghdad. In addition to a seizure attack in the ER, his
... Show MoreIn light of the rapid changes in the business environment and the entry of administrative leaders in the challenges of the atheist and twenty- increasing competition between sectors and the desire to acquire the skills, the traditional methods are no longer viable, which requires doing evaluates performance according to a more holistic, rather than limiting the performance evaluation on the financial hub that has not longer enough alone, as well as benchmarking method that has proven successful in developed countries as a way to develop and improve products and services.
I've touched your search to the development of indicators evaluating the performance and preparation of a mechanism for making comparisons of reference between o
... Show MoreLeiomyosarcoma (smooth muscle tumor) is a rare type of a malignant neoplasm of smooth
muscle. It is a resistant cancer, generally not very responsive to chemotherapy, radiationand surgery.The
aim of this study was to evaluate photodynamic therapy (PDT) as a possible basis for treatment using
(650 nm)diode laser with methyleneblue (MB) as a photosensitizer on leiomyosarcoma (LMS)cell line
(L20B) in vitro. The cytotoxic effects of 650nm diode laser 0.052 W/cm2 (power density) at different
exposure time (10, 20, and 30 min) with methylene blue at different concentrations (0.01% ,0.1 % ,1%)
was investigated on LMS cell line (L20 B). The cytotoxic effect of laser was increased with increasing
irradiation time for a certai
One of the troublesome duties in chemical industrial units is determining the instantaneous drop size distribution, which is created between two immiscible liquids within such units. In this work a complete system for measuring instantaneous droplet size is constructed. It consists of laser detection system (1mW He-Ne laser), drop generation system (turbine mixer unit), and microphotography system. Two immiscible liquids, water and kerosene were mixed together with different low volume fractions (0.0025, 0.02) of kerosene (as a dispersed phase) in water (as a continuous phase). The experiments were carried out at different rotational speed (1180- 2090 r.p.m) of the turbine mixer. The Sauter mean diameter of the drops was determined by la
... Show MoreThis research included measuring the concentrations of natural radioactive isotopes U-238 and Th-232 and radiation dose rates for selected areas of Missan province, GR-460 system was used which has the potential to measure the concentrations of natural radioactive isotopes in (ppm) unit and measuring the radiation dose rates in μR/h unit. It was also used with the system the mobile device FH-40 which measures the radiation dose rates in units μSμ/h the measurement results showed the absence of a significant increase in the U-238 and Th-232 concentration where the concentration of isotopes of U-238 and natural Th-232 (3.35-5.46) ppm respectively it is authorized and universally accepted. In terms of radiation dose rates it ranged betwe
... Show MoreS Khalifa E, N Adil A, K Nabeel O…, 2008
Since 1990 internal combustion engines and variable systems has been considered as emission. Noise can be defined as undesirable sound, and in high levels it can be considered ahealth hazard. Large internal combustion engines produce high levels of noise. In many countries there are laws restricting the noise levels in large engine rooms and fixed applications. Locomotives engines have the minimum emission influence because of noise control techniques capability.
In this paper study on a single cylinder internal combustion engine was conducted. The engine works by adding ethanol to gasoline, at variable speeds, without adding ethanol, and with adding 10 and 20% ethanol in volumetric ratio. Using one sound insulator or two or with
... Show MoreThe investigation of signature validation is crucial to the field of personal authenticity. The biometrics-based system has been developed to support some information security features.Aperson’s signature, an essential biometric trait of a human being, can be used to verify their identification. In this study, a mechanism for automatically verifying signatures has been suggested. The offline properties of handwritten signatures are highlighted in this study which aims to verify the authenticity of handwritten signatures whether they are real or forged using computer-based machine learning techniques. The main goal of developing such systems is to verify people through the validity of their signatures. In this research, images of a group o
... Show More