Preferred Language
Articles
/
bsj-6405
Dosimetric Verification of Gamma Passing Rate for Head and Neck Cases Treated with Intensity Modulated Radiation Therapy (IMRT) Treatment Planning Technique
...Show More Authors

Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at threshold 10%. The DD/DTA criteria are performed with 3%/3 mm and 2%/2 mm. A significant difference is shown between the measured and calculated point dose for the treatment plans. A comparison made between the gamma passing rate between the 2%/2 mm and 3%/3 mm shows a significant difference for local and global which shows that the 2%/2 mm are more sensitive to dose variation than 3%/3 mm. The total monitor unit (MU) shows a negative linear relationship with both criteria and %GP types. A significant correlation is shown between the total MU and global %GP at 2%/2 mm criterion. The conclusion of the study indicates that 2%/2 mm criterion is more sensitive to the dose distribution changes than the 3%/3 mm. The total number of monitor units should be taken into consideration during the planning of H&N tumors using the IMRT plans.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 12 2016
Journal Name
Wireless Networks
Low communication cost (LCC) scheme for localizing mobile wireless sensor networks
...Show More Authors

In recent years, the number of applications utilizing mobile wireless sensor networks (WSNs) has increased, with the intent of localization for the purposes of monitoring and obtaining data from hazardous areas. Location of the event is very critical in WSN, as sensing data is almost meaningless without the location information. In this paper, two Monte Carlo based localization schemes termed MCL and MSL* are studied. MCL obtains its location through anchor nodes whereas MSL* uses both anchor nodes and normal nodes. The use of normal nodes would increase accuracy and reduce dependency on anchor nodes, but increases communication costs. For this reason, we introduce a new approach called low communication cost schemes to reduce communication

... Show More
View Publication
Scopus (34)
Crossref (27)
Scopus Clarivate Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Ecological Engineering & Environmental Technology
Environmental Impact Assessment for Industrial Organizations Using Rapid Impact Assessment Matrix
...Show More Authors

View Publication
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Telkomnika (telecommunication Computing Electronics And Control)
An efficient method for stamps recognition using Haar wavelet sub-bands
...Show More Authors

View Publication
Scopus (3)
Scopus Crossref
Publication Date
Fri Mar 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Analytical Presentation for Constant Terminal Pressure Functions (Reservoir Oil-Well Systems)
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Mar 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Bionics-Based Approach for Object Tracking to Implement in Robot Applications
...Show More Authors

In this paper, an approach for object tracking that is inspired from human oculomotor system is proposed and verified experimentally. The developed approach divided into two phases, fast tracking or saccadic phase and smooth pursuit phase. In the first phase, the field of the view is segmented into four regions that are analogue to retinal periphery in the oculomotor system. When the object of interest is entering these regions, the developed vision system responds by changing the values of the pan and tilt angles to allow the object lies in the fovea area and then the second phase will activate. A fuzzy logic method is implemented in the saccadic phase as an intelligent decision maker to select the values of the pan and tilt angle based

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 17 2019
Journal Name
Aip Conference Proceedings
The interpolation effect on the spare sinogram for 3D image reconstruction
...Show More Authors

The effect of using three different interpolation methods (nearest neighbour, linear and non-linear) on a 3D sinogram to restore the missing data due to using angular difference greater than 1° (considered as optimum 3D sinogram) is presented. Two reconstruction methods are adopted in this study, the back-projection method and Fourier slice theorem method, from the results the second reconstruction proven to be a promising reconstruction with the linear interpolation method when the angular difference is less than 20°.

View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Acquired Error in using Antibiotic for Surgery Patients in Iraqi Hospitals
...Show More Authors

The use of antibiotics (AB) in surgery focused in either treating established infection or to prevent suspected post-operative infection. Inappropriate use of antibiotic for treatment of patients with common infections is a major problem worldwide, with great implications with regards to cost of treatment and development of resistance to the antimicrobial agent. Moreover, antibiotics may often be dispensed without a clear clinical indication. This study was conducted to estimate the medication errors in using antibiotic for surgery patients which may effect their wound healing. A 260 patients with clean-contaminated and contaminated surgery were included from two teaching hospitals, 160 patient from Medical city hospital and 100 fro

... Show More
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Acquired Error in using Antibiotic for Surgery Patients in Iraqi Hospitals
...Show More Authors

The use of antibiotics (AB) in surgery focused in either treating established infection or to prevent suspected post-operative infection. Inappropriate use of antibiotic for treatment of patients with common infections is a major problem worldwide, with great implications with regards to cost of treatment and development of resistance to the antimicrobial agent. Moreover, antibiotics may often be dispensed without a clear clinical indication. This study was conducted to estimate the medication errors in using antibiotic for surgery patients which may effect their wound healing. A 260 patients with clean-contaminated and contaminated surgery were included from two teaching hospitals, 160 patient from Medical city hospital and 100 from Al-

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Thu Dec 28 2017
Journal Name
Al-khwarizmi Engineering Journal
Tuning PID Controller by Neural Network for Robot Manipulator Trajectory Tracking
...Show More Authors

Ziegler and Nichols proposed the well-known Ziegler-Nichols method to tune the coefficients of PID controller. This tuning method is simple and gives fixed values for the coefficients which make PID controller have weak adaptabilities for the model parameters variation and changing in operating conditions. In order to achieve adaptive controller, the Neural Network (NN) self-tuning PID control is proposed in this paper which combines conventional PID controller and Neural Network learning capabilities. The proportional, integral and derivative (KP, KI, KD) gains are self tuned on-line by the NN output which is obtained due to the error value on the desired output of the system under control. The conventio

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 02 2023
Journal Name
Journal Of Engineering
Reducing Maintenance Costs for Government Projects in Iraq Using Performance Indicators
...Show More Authors

Institutions and companies are looking to reduce spending on buildings and services according to scientific methods, provided they reach the same purpose but at a lower cost. On this basis, this paper proposes a model to measure and reduce maintenance costs in one of the public sector institutions in Iraq by using performance indicators that fit the nature of the work of this institution and the available data. The paper relied on studying the nature of the institution’s work in the maintenance field and looking at the type of data available to know the type and number of appropriate indicators to create the model. Maintenance data were collected for the previous six years by reviewing the maintenance and financial dep

... Show More
View Publication Preview PDF
Crossref