The current research is a spectroscopic study of Coumarin 334 dissolved in methanol. The range of concentrations of the prepared stock solution was (3.39x10-9 to 2.03x10-8) M. Some optical characteristics of this dye were investigated such as absorbance and transmission spectra, absorption coefficient, refractive and extinction coefficients, oscillation and dispersion energies, and energy band gap. The absorbance spectra were recorded at 452 nm using Broad Band Cavity Enhanced Absorption Spectroscopy (BBCEAS) which depends on increasing the path length of the traveling light from the source to the detector. The minimum absorbance amount was 0.07 with a low concentration of 3.39x10-9 M. As a result, the other optical properties were calculated on the basis of the lowest values of absorbance. The energy band gap, which is important to detect the electronic band structure of the material, was determined; it was found to be equal to ~2.55 eV. The low values of the concentration made less collision between the molecules in the materials and the incident light. This led to a reduction in the background noise and in the percentages of losses. Furthermore, the dispersion and single oscillator energies, which help to calculate the average strength of the inter-band optical transitions and to prepare the quantifiable information about the band structure of the material, were calculated to reduce with the increasing concentrations. The refractive and extinction coefficients were determined because they are considered important factors for the optical materials and found to increase with the increasing concentrations. As a result, the study of the optical behavior of Coumarin 334 highlighted the promising materials for photonics applications at very low concentrations. All these properties are considered the main factors to determine the usefulness of the materials in advanced applications and to develop the performance of the devices which depend on the optical characteristics.
Elastic magnetic M1 electron scattering form factor has been calculated for the ground state J,T=1/2-,1/2 of 13C. The single-particle model is used with harmonic oscillator wave function. The core-polarization effects are calculated in the first-order perturbation theory including excitations up to 5ħω, using the modified surface delta interaction (MSDI) as a residual interaction. No parameters are introduced in this work. The data are reasonably explained up to q~2.5fm-1 .
The importance of this study of the growing importance of perception of touch and its association with the job performance of industrial product since the perception stereotactic means he means practiced by the individual through job performance and has assets of knowledge in the mind of the user and require him to mind the capabilities and knowledge cognitive following their individual focus Zhennea.oanfalh following their enthusiasm when using Sense of touch. The study in the first chapter of the research problem to reveal the role played by the process of cognition and its relationship with the touch function of the industrial product and the associated defect in performance and harder to use. The study also pointed to the research ob
... Show MoreObjectives: to assess Socio Demographic, Reproductive Characteristics, and healthy dietary behaviors. among women with osteoporosis . To determine the relationship between the socio demographic characteristics, reproductive data and dietary related behaviors. Methodology: A descriptive analytic design was conducted on Non- Probability ( purposive sample) of (90) women who have suffering from osteoporosis attend to (DEXADual-Energy X-ray Absorptiometry) unit in Merjan Teaching Hospital in Hilla City. A questionnaire has been used as a tool of data collection and consists of three part ;including : Soci
ABSTRACT Pulmonary alveolar microlithiasis is rare infiltrative pulmonary disease characterized by intra-alveoli deposition of microliths. We present a familial case of an adult female with complaint of progressive shortness of breath on exertion. Chest radiograph showed innumerable tiny dense nodules, diffusely involving both lungs mainly the lower zones. High-resolution CT scan illustrated widespread intra-alveolar microliths, diffuse ground-glass attenuation areas and septal thickening predominantly in the basal regions. Chest radiograph is all that is needed for the diagnosis of this case but CT scan was done to demonstrate the extent and severity of this disease
Polycystic ovary syndrome(PCOS) is a heterogeneous disorder of uncertain etiology , it is the most common endocrinopathy in women and most common cause of anovulatery infertility ,characterized by chronic anovulation and hyperandrogenemia .The present study was designed to investigate the effect of silymarin which is known to have antioxidant and insulin sensitivity effects on the levels of glucose, insulin ,testosterone ,leutinizing hormone(LH) and progesterone .Ovulation rate and Homeostasis Model Assessment of insulin Resistance (HOMA) ratio were determined .A 3-months of treatment were conducted in 60 PCOS patients in three well-matched groups .The first one (n=20),received silymarin(750mg/day) .The second group received
... Show MoreRheumatoid arthritis is a chronic systemic inflammatory disease. Inflammation leads to joint damage and increases the risk of cardiovascular diseases. Neutrophil lymphocyte ratio (NLR) is a measure of inflammation in many diseases. Therefore, we aimed to evaluate the usefulness of NLR to detect inflammation in RA, and its correlation to RA disease activity indices and some hematological parameters. A cross-sectional study involving 24 patients with active rheumatoid arthritis (RA) who are using MTX participated in this study. All patients were clinically evaluated using disease activity score of 28 joints (DAS28) and simplified disease activity index (SDAI), whereas functional disability was assessed by health assessment questionnaire di
... Show MoreThis research aims to know the essence of the correlative relationship between tactical thinking and solving mathematical problems. The researchers followed the descriptive research method to analyze relations, as all students from the mathematics department in the morning study were part of the research group. The research sample of (100) male and female students has been chosen based on the arbitrators' views. The tools for studying the sample of research composed of (12) items of the multiple-choice test in its final form to measure tactical thinking and require establish-ing a test of (6) test-type paragraphs to solve mathematical problems. The findings showed that sample students' tactical thinking and their capacity to overcome mathem
... Show MoreAn Intelligent Internet of Things network based on an Artificial Intelligent System, can substantially control and reduce the congestion effects in the network. In this paper, an artificial intelligent system is proposed for eliminating the congestion effects in traffic load in an Intelligent Internet of Things network based on a deep learning Convolutional Recurrent Neural Network with a modified Element-wise Attention Gate. The invisible layer of the modified Element-wise Attention Gate structure has self-feedback to increase its long short-term memory. The artificial intelligent system is implemented for next step ahead traffic estimation and clustering the network. In the proposed architecture, each sensing node is adaptive and able to
... Show MoreThe direct electron transfer behavior of hemoglobin that is immobilized onto screen-printed carbon electrode (SPCE) modified with silver nanoparticles (AgNPs) and chitosan (CS) was studied in this work. Cyclic voltametry and spectrophotometry were used to characterize the hemoglobin (Hb) bioconjunction with AgNPs and CS. Results of the modified electrode showed quasi-reversible redox peaks with a formal potential of (-0.245 V) versus Ag/AgCl in 0.1 M phosphate buffer solution (PBS), pH7, at a scan rate of 0.1 Vs-1. The charge transfer coefficient (α) was 0.48 and the apparent electron transfer rate constant (Ks) was 0.47 s-1. The electrode was used as a hydrogen peroxide biosensor with a linear response over 3 to 240 µM and a detection li
... Show More