Attacking a transferred data over a network is frequently happened millions time a day. To address this problem, a secure scheme is proposed which is securing a transferred data over a network. The proposed scheme uses two techniques to guarantee a secure transferring for a message. The message is encrypted as a first step, and then it is hided in a video cover. The proposed encrypting technique is RC4 stream cipher algorithm in order to increase the message's confidentiality, as well as improving the least significant bit embedding algorithm (LSB) by adding an additional layer of security. The improvement of the LSB method comes by replacing the adopted sequential selection by a random selection manner of the frames and the pixels with two secret random keys. Therefore, the hidden message remains protected even if the stego-object is hacked because the attacker is unable to know the correct frames and pixels that hold each bit of the secret message in addition to difficulty to successfully rebuild the message. The results refer to that the proposed scheme provides a good performance for evaluation metric that is used in this purpose when compared to a large number of related previous methods.
Background: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center of t
... Show MoreStaphylococcal enterotoxin B (SEB) is a potent superantigen produced by
Acute Respiratory Distress Syndrome (ARDS) is triggered by a variety of insults, such as bacterial and viral infections, including SARS-CoV-2, leading to high mortality. In the murine model of ARDS induced by Staphylococcal enterotoxin-B (SEB), our previous studies showed that while SEB triggered 100% mortality, treatment with Resveratrol (RES) completely prevented such mortality by attenuating inflammation in the lungs. In the current study, we investigated the metabolic profile of SEB-activated immune cells in the lungs following treatment with RES. RES-treated mice had higher expression of miR-100 in the lung mononuclear cells (MNCs), which targeted mTOR, leading to its decreased expression. Also, Single-cell RNA-seq (scRNA seq)
... Show MoreBackground and Aim: The aryl hydrocarbon receptor (AhR) plays a pivotal role in spermatogenesis through its regulatory functions in redox balance and gene expression. This study aimed to investigate the effects of resveratrol (RES), a polyphenolic AhR modulator, and CH223191, a selective AhR antagonist, on male reproductive function in rats by assessing sperm quality, oxidative stress, testicular histopathology, and AhR gene expression. Materials and Methods: Forty adult male rats were randomly divided into four groups: (i) Control, (ii) dimethyl sulfoxide (vehicle), (iii) RES (100 mg/kg i.p., twice weekly), and (iv) AhR⁻ (CH223191, 10 mg/kg i.p., twice weekly), treated for 60 days. Post-treatment, sperm motility, survival, viabi
... Show MoreThe current study sheds light on the measurement and estimation of the radioactivity of radionuclides (238U, 226Ra, 232Th, and 40k) in natural waters of different regions of Nineveh Governorate in Iraq.15 samples were collected from different sources of natural waters, where gamma-ray spectroscopy was used using NaI)TI) sodium iodide detector to determine the concentration of radioactivity in the samples. According to the results, the radioactivity concentration in the tested water sample were ranged from 0.36 ± 0.04-1.57 ± 0.09with an average value of 0.69 ± 0.06 Bq/l for 238U, and 2.9 ± 0.02-0.88 ± 0.03 with an average value of 0.65 ± 0.03 Bq/l for 226Ra Bq/l
... Show More