Trichomonas vaginalis is a causative agent of trichomoniasis , one of the most common non-viral sexually transmitted disease (STD) over all the world, especially in immunocompromised women such as pregnant. Wet smear and Giemsa stain are the current methods used in hospital to diagnosis trichomoniasis. DNA based diagnosis is still to be validated to diagnose the local isolates, the objective of the present study was to compare the conventional methods of disease diagnosis with the DNA-based method to diagnose Trichomonas incidence in local isolates. In the present study, 105 samples were collected from outpatient women (18-45 years) of Maternity hospital in Mosul who showed a classical presentation of Trichomonas infection including foul-smelling vaginal discharge with a pH exceeding 4.5. Samples underwent microscopic examination and nucleic acid detection of AP65-1 gene, the wet smear test showed that 16.18% of the collected specimen were positive while the parasite appeared only in 8.9% of the samples stained with Giemsa dye, the molecular screening for AP65-1gene that encodes for the surface attachment protein showed high sensitivity level of 100 at 50 specificity level in compare with other routine methods, the algorithm was evaluated according to specificity, sensitivity, and predictive values. Random Amplification Polymorphic DNA (RAPD) was achieved to estimate genetic indices among isolated strains. Phylogenetic analysis was performed using PAST (Paleontological statistics software) and dendrogram with neighboring clusters was constructed. According to the outcomes of research, we recommended to utilize a probiotic vaccines and molecular silencing vaccine (like miRNA sense and antisense oligonucleotides) as a treatment in.
KE Sharquie, GA Ibrahim, AA Noaimi, HK Hamudy, J Saudi Soc Dermatol Dermatol Surg, 2010 - Cited by 2
Structural buildings consist of concrete and steel, and these buildings have confronted many challenges from various aggressive environments against the materials manufactured from them. It contains high water levels and buildings whose concrete cover may be damaged and thus lead to the deterioration and corrosion of steel. It was important to have an alternative to steel, such as the glass fiber reinforced polymer (GFRP), which is distinguished by its great effectiveness in resisting corrosion, as well as its strong tensile resistance. Still, one of its drawbacks is that it has a low modulus of elasticity. This research article aims to conduct a numerical study using the nonlinear fi
In this paper, construction microwaves induced plasma jet(MIPJ) system. This system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate by using flow meter, to diagnose microwave plasma optical emission spectroscopy(OES) was used to measure the important plasma parameters such as electron temperature (Te), residence time (Rt), plasma frequency (?pe), collisional skin depth (?), plasma conductivity (?dc), Debye length(?D). Also, the density of the plasma electron is calculated with the use of Stark broadened profiles
This paper presents a numerical analysis using ANSYS finite element program to simulate the reinforced concrete slabs with spherical voids. Six full-scale one way bubbled slabs of (3000mm) length with rectangular cross-sectional area of (460mm) width and (150mm) depth are tested as simply supported under two-concentrated load. The results of the finite element model are presented and compared with the experimental data of the tested slabs. Material nonlinearities due to cracking and crushing of concrete and yielding of reinforcement are considered. The general behavior of the finite element models represented by the load-deflection curves at midspan, crack pattern, ultimate load, load-concrete strain curves and failure m
... Show MoreIn this paper Heun method has been used to find numerical solution for first order nonlinear functional differential equation. Moreover, this method has been modified in order to treat system of nonlinear functional differential equations .two numerical examples are given for conciliated the results of this method.
In this study, nanocomposites have been prepared by adding
multiwall carbon nanotubes (MWCNTs) with weight ratios (0, 2, 3,
4, 5) wt% to epoxy resin. The samples were prepared by hand lay-up
method. Influence of an applied load before and after immersion in
sodium hydroxide (NaOH) of normality (0.3N) for (15 days) at
laboratory temperature on wear rate of Ep/MWCNTs
nanocomposites was studied. The results showed that wear rate
increases with increasing the applied load for the as prepared and
immersed samples and after immersion. It was also found that epoxy
resin reinforced with MWCNTs has wear rate less than neat epoxy.
The sample (Ep + 5wt% of MWCNTs) has lower wear rate. The
immersion effect in base so