In this study the Entrance Surface Dose (ESD) received by pediatrics patients undergoing chest, abdomen and skull X-ray examinations was estimated. The study was conducted in two hospitals in Najaf city where three radiographic systems were considered. The study participants were classified into four age groups 0-1 , 1-5 , 5-10 and 10-15 years. Calculations were performed using exposure factors, kVp, mAs and focal-skin distance, together with patient data age. The ESD was calculated for the involved patients who underwent an Antero-posterior (AP) chest, abdomen and skull X-ray examination. The resulted data were analyzed and compared with international dose references. For all studied radiographic examinations and all X-ray machines, the ESD increases with age. The lowest recorded radiation dose was from hospital 1 machine 2. In this facility ESD ranged from 19.93 µGy to 67.66 µGy for chest X-ray, from 39.03 µGy to 82.63 µGy for abdomen (AP), and from 35.47 µGy to 94.27 µGy for skull (AP). In contrast the highest dose levels are recorded from hospital 2 machine 1; the minimum ESD for chest X-ray is 247.51 µGy and the maximum is 2393.12 µGy; for abdomen X-ray the lowest ESD is 269.05 µGy and the highest value is 5106.15 µGy; and for skull X-ray minimum values is 430.96 µGy and the maximum value is 3072.77 µGy. In conclusion, for the considered pediatrics examinations, most of ESD values are within the international acceptable level and some are higher >100% .
This study aims to know the types of insects belonging to the Sphaeroceridae family. During this study, one species registered for this family for the first time to Iraq (New genus and species). It is using two methods of killing are injurious machine (knife) and toxic substance (strychnine). Four areas within Karbala governorate studied and identified to know their spread and time of presence on the body during the stages of decomposition. During this experiment, the bodies of dogs used to identify types of insects attracted to the body during four seasons. The results indicated the presence of the species
Different bremsstrahlung spectra from tungsten anode x-ray tube generated at 30, 40 and 50 kV have been examined theoretically and experimentally for an attempt to find a most suitable spectrum to radiograph a test object of 0.01 cm thickness of Cu and Ag. The high contrast using this suitable spectrum is demonstrated and the possible effects of fluorescent radiation are discussed.
Surgical site infections are the second most common type of adverse events occurring in hospitalized patients. Surgical antibiotic prophylaxis refers to the use of preoperative and postoperative antibiotics to decrease the incidence of postoperative wound infections. The objective of this study was to evaluate the antibiotic administration pattern for surgical antibiotic prophylaxis and the adherence to American Society of Health-System Pharmacists surgical antibiotic prophylaxis guideline in Medical City Teaching Hospitals/Baghdad. The medical records of one hundred patients who underwent elective surgical procedures were reviewed. Adherence to the recommendations of American society of health‑system pharmacists guideline was ass
... Show MoreObjective: To assess the impact of a social support for pregnant women upon their pregnancy outcome Methodology: A descriptive purposive study was used to assess the impact of a social support on their pregnancy outcomes. The study was conducted from (22 \ September \ 2020 to 15 \ February \ 2021). A non-probability sample (purposive sample) was selected from 100 women. Data were collected through an interview with the mother in the counseling clinic, during the third trimester of pregnancy, as well as after childbirth in the labor wards to assess the outcome of pregnancy. Data were analyzed through descriptive statistics (frequency and percentages). Results: The most important thing observed in this study was the positive pregnancy outcome
... Show MoreBumpiness in the atmosphere is the vertical movement of air, whether
upward or downward movement and the bumpiness is accompanied by areas
of unrest in the air and wind. And contribute to each of the coups thermal
fronts, wind, wind and thunderstorms. Moreover, bumpiness is net of the
reasons that lead to circumstances is appropriate to cut the wind, and this
contributes to the formation of bumpiness in the atmosphere. The study found
that the noon of the times, which is expected to occur where clear-air
bumpiness during flights because of the warmth of the earth's surface. The
study found increased incidence of air hole during the summer, especially
July, due to increased incidence of coup surface, while the s
هدفت الدراسة لالقاء الضوء على وضع المرأة في التعليم العالي في العراق خلال الاعوام الدراسية: 2008 - 2009, 2010 – 2011 و2011- 2012. تتيح القوانين والتعليمات في التعليم العالي في العراق فرص متكافئة للاناث والذكور للتسجيل في الدراسات الاولية والعليا، وكذلك عدم التمييز في الرواتب الشهرية للمنتسبين وفقا لنوع الجنس (الجندر ). بلغ متوسط عدد الاناث في مرحلة الدراسة الاولية في مؤسسات التعليم العالي في العراق لثلا
... Show MoreI came back and made my jewelery from the first research or studies known to man, and the oldest era and confirmed the problem of searching for the links of sweets and admiration of the magnificence of the effectiveness of the search for the importance of preserving the heritage of the Iraqi civilization in its original creative aspects. Metal in Iraq, Head Costume, Neck Costume, Party Costume (Hands and Legs). The main results of the research were;
1-Contemporary folk jewelry in Iraq was characterized by design units for use.
Dependence in the feed industry in the form of laboratory mold.
Radiation measuring devices need to periodic calibration process to examine their sensitivity and the extent of the response. This study is used to evaluate the radiation doses of the workers in the laboratories of the Directorate of Safety as a result of the use of point sources in calibrating of the devices in two ways, the first is the direct measurement by the FAG device and the others using RESRAD and RAD PRO programs. The total doses values using FAG were (2.57 μSv/y, 102.3 μSv/y and 20.75 μSv/y for TLD laboratory, Gamma spectroscopy analyses (GSA) laboratory and equipment store respectively, and the total doses that calculated using RESRAD and RAD PRO were 1.518 μSv/y, 76.65 μSv/y and 21.2 μSv/y for the above laboratories. t
... Show More