In this study the Entrance Surface Dose (ESD) received by pediatrics patients undergoing chest, abdomen and skull X-ray examinations was estimated. The study was conducted in two hospitals in Najaf city where three radiographic systems were considered. The study participants were classified into four age groups 0-1 , 1-5 , 5-10 and 10-15 years. Calculations were performed using exposure factors, kVp, mAs and focal-skin distance, together with patient data age. The ESD was calculated for the involved patients who underwent an Antero-posterior (AP) chest, abdomen and skull X-ray examination. The resulted data were analyzed and compared with international dose references. For all studied radiographic examinations and all X-ray machines, the ESD increases with age. The lowest recorded radiation dose was from hospital 1 machine 2. In this facility ESD ranged from 19.93 µGy to 67.66 µGy for chest X-ray, from 39.03 µGy to 82.63 µGy for abdomen (AP), and from 35.47 µGy to 94.27 µGy for skull (AP). In contrast the highest dose levels are recorded from hospital 2 machine 1; the minimum ESD for chest X-ray is 247.51 µGy and the maximum is 2393.12 µGy; for abdomen X-ray the lowest ESD is 269.05 µGy and the highest value is 5106.15 µGy; and for skull X-ray minimum values is 430.96 µGy and the maximum value is 3072.77 µGy. In conclusion, for the considered pediatrics examinations, most of ESD values are within the international acceptable level and some are higher >100% .
A solid Phase Extraction (SPE) followed by HPLC-UV method is described for the simultaneous quantitative determination of nine priority pollutant phenols : Phenol, 2- and 4-Nitrophenol, 2,4-Dimethylphenol, 2-, 2,4-Di-, 2,4,6-Tri-, and Penta- chlorophenol, 4 Chloro-3-methylphenol. The phenols were separated using a C-18 column with UV detector at wave length of 280nm. The Flow of mobile phase was isocratic consisted of 50:50 Acetonitrile: phosphate buffer pH=7.1, column temperature 45 C°, Flow Rate 0.7 ml/min. Calibration curves were linear (R2 = 0.9961-0.9995). The RSDs (1.301-5.805)%, LOD(39.1- 412.4) µg/L, LOQ(118.5-1250.8) µg/L, the Robustness (1.55-4.89), Ruggedness (2.82-4.00), Repeatability (2.1-4.95), Recoveries%
... Show MoreThe objective of this study is to evaluate the level of cytokines IL-1?, IL-10 and IL-17A in the serum of patients with Alzheimer's disease (AD), vascular dementia (VD) and down syndrome (DS). The results showed that Serum level of IL-1? was significantly increased in AD patients (3.79 ± 0.26 pg/ml) as compared with DS patients (2.78 ± 0.39 pg/ml) or controls (2.78 ± 0.22 pg/ml), while no significant difference was observed between AD and VD (3.25 ± 0.20 pg/ml) patients or between VD patients, DS patients and controls. The serum level of IL-10 was approximated in VD and DS patients and controls (3.39 ± 0.24, 2.77 ± 0.39 and 3.41 ± 0.35 pg/ml, respectively), but was significantly (P ? 0.05) increased in AD patients (5.73 ± 0.55 pg/ml
... Show MoreThis study was aimed to conduct one of the vertical garden systems , selecting suitable plant species that with stand the climate conditions of Baghdad city in outer space to determine the appropriate growing medium for the (LWS), and to assess the impact of spraying with potassium silicate on the resistance of the cultivated plants to heat stresses . The study carried out at at Al-Batool Park of (Al-Kadhimiya Holy City). Two experiments were carried out, each one with a different plant species, including Wedelia trilobata and Tradescantia pallida, during the winter season of 2021 and summer season of 2022. The experiments were designed using a split block design. The experiments included two factors, the first being the growing med
... Show MoreAn experimental and numerical study has been carried out to investigate the heat transfer by natural convection in a three dimensional annulus enclosure filled with porous media (silica sand) between two inclined concentric cylinders with (and without) annular fins attached to the inner cylinder under steady state condition; The experiments were carried out for a range of modified Rayleigh number (0.2 ≤Ra*≤ 11) and extended to Ra* =500 for numerical study, annulus inclination angle of (δ = 0˚, 30˚, 60˚ and 90˚). The numerical study was to write the governing equation under an assumptions used Darcy law and Boussinesq’s approximation and then solved numerically using finite difference approximation. It was found that the averag
... Show MoreThe Dynamic Load Factor (DLF) is defined as the ratio between the maximum dynamic and static responses in terms of stress, strain, deflection, reaction, etc. DLF adopted by different design codes is based on parameters such as bridge span length, traffic load models, and bridge natural frequency. During the last decades, a lot of researches have been made to study the DLF of simply supported bridges due to vehicle loading. On the other hand, fewer works have been reported on continuous bridges especially with skew supports. This paper focuses on the investigation of the DLF for a highly skewed steel I-girder bridge, namely the US13 Bridge in Delaware State, USA. Field testing under various load passes of a weighed load vehicle was u
... Show MoreABSTRACT Background: chronic periodontitis and rheumatoid arthritis are widely prevalent diseases and are characterized by tissue destruction due to chronic inflammation. Recently, there is growing evidence that the two diseases share many pathological features the aims of the study To determine the periodontal health status in patient have chronic periodontitis with rheumatoid arthritis and compare it with those having chronic periodontitis without Rheumatoid arthritis and determine the serum levels of interleukin -17(IL-17), tumor necrosis factor- alpha (TNF-α ) in both groups and compare with the control group (subject samples neither have periodontitis nor arthritis ) and correlate these immunological markers with the periodontal p
... Show MoreWe observed strong nonlinear absorption in the CdS nanoparticles of dimension in the range 50-100 nm when irradiant with femtosecond pulsed laser at 800 nm and 120 GW/cm 2 irradiance intensity. The repetition rate and average power were 250 kHz and