In this study the Entrance Surface Dose (ESD) received by pediatrics patients undergoing chest, abdomen and skull X-ray examinations was estimated. The study was conducted in two hospitals in Najaf city where three radiographic systems were considered. The study participants were classified into four age groups 0-1 , 1-5 , 5-10 and 10-15 years. Calculations were performed using exposure factors, kVp, mAs and focal-skin distance, together with patient data age. The ESD was calculated for the involved patients who underwent an Antero-posterior (AP) chest, abdomen and skull X-ray examination. The resulted data were analyzed and compared with international dose references. For all studied radiographic examinations and all X-ray machines, the ESD increases with age. The lowest recorded radiation dose was from hospital 1 machine 2. In this facility ESD ranged from 19.93 µGy to 67.66 µGy for chest X-ray, from 39.03 µGy to 82.63 µGy for abdomen (AP), and from 35.47 µGy to 94.27 µGy for skull (AP). In contrast the highest dose levels are recorded from hospital 2 machine 1; the minimum ESD for chest X-ray is 247.51 µGy and the maximum is 2393.12 µGy; for abdomen X-ray the lowest ESD is 269.05 µGy and the highest value is 5106.15 µGy; and for skull X-ray minimum values is 430.96 µGy and the maximum value is 3072.77 µGy. In conclusion, for the considered pediatrics examinations, most of ESD values are within the international acceptable level and some are higher >100% .
The design of this paper is to find the possible correlation of Epstein Barr virus infection ina group of Iraqi women with cervical carcinoma though detection of Latent Membrane Protein 1 (LMP1) in these cervical tissues. Paraffinized blocks of two groups were included. The first sample of 30 cervical carcinomatous tissues and 15 biopsies from an apparently normal cervical tissues. All the samples were sectioned on a positive charged slides with 4 mm – thickness then submitted for immunohistochemical (IHC) staining to detect viral LMP1 expression. Sixty three percentage (19 out of 30) of the studies group showed positive overexpression as shown in with a significant association of the expression with cervical cancer with a significant ass
... Show MorePOSSIBILITY OF APPLICATION THE BALANCED SCORECARD IN THE IRAQI INDUSTRIAL COMPANIES: A PROPOSED MODEL
A simple, accurate and sensitive spectrophotometric way is used to determine Bisacodyl in pure and pharmaceutical preparations. The proposed method depends on using 2,4-Dinitrophenylhydrazine as chromogenic reagent . The method was based on the oxidative coupling reaction of Bisacodyl with 2,4-Dinitrophenylhydrazine with Sodium periodate in the presence of sodium hydroxide as alkaline media to form red water soluble dye product , that has a maximum absorption at ?max 522nm . Beer ,s law is obeyed in the concentration of (2.00–20.00) ?g.ml -1 .The molar absorptivity is (6505) L.mol-1.cm-1,a sandall sensitivity of(0.0555) ?g.cm-2), correlation coefficient of (0.9970) , Limitof detection (LOD) (0.0312 ?g.ml-1), limit of Quantitation (LOQ) (
... Show MoreCarbon dioxide (CO2) flooding is an EOR technique in which carbon dioxide is injected into the reservoir to improve the oil recovery. The reservoir oil and rock properties are altered when carbon dioxide interacts with the oil and rock present in the reservoir. Carbon dioxide injection alters the oil and rock properties by causing reduction in oil viscosity, oil swelling and wettability alteration of the rock. This paper will present a proposal to study the wettability alteration in carbonate formations during miscible carbon dioxide flooding. In miscible carbon dioxide flooding, the injection pressure of carbon dioxide would be kept above the minimum miscibility pressure. Thus carbon dioxide is miscible with the oil present in the reservoi
... Show MoreCopper (Cu) Zinc (Zn) and Magnesium (Mg) in serum, RBC, urine and dialyzate fluids were
studied in 39 patients, who have been undergoing chronic haemodialysis treatment. They were
divided in to polyuric , oliguric and anuric depending on their urinary output. Elevated serum and
RBC Mg was observed before dialysis, while decreased serum and RBC level was noticed except
serum Mg of polyuric patients. Before dialysis elevated serum and RBC Zn were observed. While
after dialysis these parameters were increased. Normal RBC Cu value before dialysis was observed.
While low serum Cu was noticed. After dialysis serum Cu showed raised value, while RBC level
decreased in oliguric and increased in polyuric patients. Zn / Cu rati
Straight tendons in pretensioned members can cause high-tensile stresses in the concrete extreme fibers at end sections because of the absence of the bending stresses due to self-weight and superimposed loads and the dominance of the moment due to prestressing force alone. Accordingly, the concrete tensile stresses at the ends of a member prestressed with straight tendons may limit the service load capacity of the member. It is therefore important to establish limiting zone in the concrete section within which the prestressing force can be applied without causing tension in the extreme concrete fibers. Two practical methods are available to reduce the stresses at the end sections due to the prestressing force. The first method based
... Show MoreBackground: Adenoid cystic carcinoma (ACC) constitutes about 4% of salivary epithelial tumors and is the second common malignant epithelial salivary gland tumor involving both the major and minor salivary glands. Aims of the study is to evaluate immunohistochemical expression of Ki67 and p53 proteins in ACC. Materials and Methods: immunohistochemical analyses of fifteen cases of formalin – fixed paraffin – embedded tissues blocks of ACC of salivary glands using ki67 and p53 antibodies. Results: ki67 was expressed in 6 of 15 ACC (40%) while p53 aberration was demonstrated in 11 of tumor (73.3%). There was a statistically significant difference between the expression of ki67 and p53 proteins in ACC cases (p value = 0.041). Pearson’s cor
... Show MoreThe main goal of this work is to obtain the plasma electron temperature Te by optical emission spectroscopy of low pressure microwave argon plasma, as a function of working pressure and microwave power. A plasma system was designed and constructed in our laboratory using a magnetron of domestic microwave oven with power 800W without any commercial part. The applied voltage on the magnetron electrical circuit is changed for the purpose of obtaining the variable values of the microwave power. The spectral detection is performed with a spectrometer of wavelength range (200−1000nm). The working pressure and magnetron applied voltage were 0.3-3.0mbar and 180-240V, respectively. Two methods had been applied to estimate the electron temperatu
... Show More