Preferred Language
Articles
/
bsj-5899
Estimation of Radiation Dose from Most Common Pediatrics Radiographic Examinations within Main Central Hospitals in Najaf City, Iraq
...Show More Authors

In this study the Entrance Surface Dose (ESD) received by pediatrics patients undergoing chest, abdomen and skull X-ray examinations was estimated. The study was conducted in two hospitals in Najaf city where three radiographic systems were considered. The study participants were classified into four age groups 0-1 ,  1-5 ,  5-10  and  10-15  years. Calculations were performed using exposure factors, kVp, mAs and focal-skin distance, together with patient data age. The ESD was calculated for the involved patients who underwent an Antero-posterior (AP) chest, abdomen and skull X-ray examination. The resulted data were analyzed and compared with international dose references. For all studied radiographic examinations and all X-ray machines, the ESD increases with age. The lowest recorded radiation dose was from hospital 1 machine 2. In this facility ESD ranged from 19.93  µGy to  67.66  µGy for chest X-ray, from  39.03  µGy to  82.63  µGy for abdomen (AP), and from  35.47  µGy to  94.27  µGy for skull (AP). In contrast the highest dose levels are recorded from hospital 2 machine 1; the minimum ESD for chest X-ray is 247.51  µGy and the maximum is  2393.12  µGy; for abdomen X-ray the lowest ESD is  269.05  µGy and the highest value is  5106.15  µGy; and for skull X-ray minimum values is  430.96  µGy and the maximum value is  3072.77  µGy. In conclusion, for the considered pediatrics examinations, most of ESD values are within the international acceptable level and some are higher >100% .

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Feb 01 2023
Journal Name
Journal Of Safety Research
Analysis of prevention through design studies in construction: A subject review
...Show More Authors

View Publication
Scopus (16)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Generalizations of Fuzzy k-ideals in a KU-algebra with Semigroup
...Show More Authors
Abstract<p>We present the notion of bipolar fuzzy k-ideals with thresholds (<italic>θ, λ</italic>) of a KU-algebra with semigroup and give some basic properties of this ideal. Also, we study some relations about a bipolar fuzzy k-ideal with thresholds (<italic>θ, λ</italic>) and a k-ideal of a KU-semigroup.</p>
View Publication
Scopus (10)
Crossref (2)
Scopus Crossref
Publication Date
Tue Mar 31 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion of Electrical Submersible Pumps (ESP) In South Rumaila Oil Field
...Show More Authors

   Rotating cylinder electrode (RCE) is used . in weight loss technique , the salinity is 200000 p.p.m, temperatures are (30,5060,7080Co) . the velocity of (RCE) are (500,1500,3000 r.p.m). the water cut (30% , 50%). The corrosion rate of carbon steel increase with increasing rotating cylinder velocity. In single phase flow, an increase im rotational velocity from 500 to 1500 r.p.m, the corrosion rate increase from 6.88258 mm/y to 10.11563 mm/y respectively.

   In multiphase flow, an increase in (RCE) from 500 to 1500 r.p.m leads to increase in corrosion rate from 0.786153 to 0.910327 mm/y respectively. Increasing brine concentration leads to increase in corrosion rate at water cut 30%.

View Publication Preview PDF
Publication Date
Sun Dec 01 2024
Journal Name
Toxicology Reports
The impact of methamphetamine on liver injury in Iraqi male addicts
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Carbon Steel in Hydrochloric Acid under Dynamic Conditions
...Show More Authors

In this work, studying the effect of ethylenediamine as a corrosion inhibitor was investigated for carbon steel in aerated HCl solution in range of 0.1-1N under dynamic conditions, i.e., rotational velocity of 400–1200 rpm in the temperature range 35 – 65 ºC.  Weight loss method was employed in absence and presence of the inhibitor as an adsorption type in concentration range 1000 – 5000 ppm using rotating cylinder specimens. The experimental results showed that corrosion rate in absence and presence of inhibitor is increased with increasing temperature, rotational velocity and concentration of acid. It is decreased with increasing inhibitor concentration for the whole range of temperature, rotational velocity and concentrati

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Effect of Atenolol on CK-MB Levels in Hypertensive Patients
...Show More Authors

Atenolol is one of beta-adrenergic receptor blocking agent. It is widely used for the treatment of hypertension as a selective antihypertensive drug. But long term usage of atenolol may cause one of the cardiovascular diseases like myocardial infarction. To prove the relationship between atenolol and cardiovascular disease, measurement of creatinekinase-MB as a diagnostic indicator in early and long term usage of this drug by hypertensive patients is recommended.  A comparative study was conducted in Al-Yarmouk Teaching Hospital–Emergency Department- on 30 hypertensive patients using atenolol. They were divided into (2) groups A and B according to the duration of the drug usage. Group A- (15) patients with a mean age (56

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Detection of line shape parameters in normal and abnormal biological tissues
...Show More Authors

Doppler broadening technique is suggested to monitor the development of tumours. It depends on the sensitivity of positronium (Ps) annihilation parameters to the sub- microstructural changes in biological tissues. This technique uses high resolution HpGe detector to measure the lineshape parameters (S and W) in normal mice's mammary tissues and adenocarcinoma mammary tissues as a function of tumour growth. The results demonstrate that the central parameter (S) decreases and the wing parameter (W) increases as the tumour grow. It is found that the S parameter changes considerably with the distribution of voids which are affected by the tumour development. Therefore the present technique can successfully be employed to monitor the developm

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 30 2011
Journal Name
Al-kindy College Medical Journal
Early and late Biliary Complications of Laparoscopic Cholecystectomy in Acute Cholecystitis
...Show More Authors

Background: Laparoscopic cholecystectomy
has become the standard of care for the
elective management of cholelithiasis. Little
information exists, however, regarding the
appropriateness of this procedure in the setting
of acute symptomatology.
Objective: This study was designed to
evaluate the outcome of laparoscopic
cholecystectomy in acute and severe acute
cholecystitis based on early and late biliary
complications, their incidence and
management, and conversion rates to open
surgery.
Methods: A prospective study done between
April 2007 and November 2010, in the
department of general surgery, medical city
teaching hospital, Baghdad. Includes patients
with acute cholecystitis admitted f

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Prediction of bubble size in Bubble columns using Artificial Neural Network
...Show More Authors

In the literature, several correlations have been proposed for bubble size prediction in bubble columns. However these correlations fail to predict bubble diameter over a wide range of conditions. Based on a data bank of around 230 measurements collected from the open literature, a correlation for bubble sizes in the homogenous region in bubble columns was derived using Artificial Neural Network (ANN) modeling. The bubble diameter was found to be a function of six parameters: gas velocity, column diameter, diameter of orifice, liquid density, liquid viscosity and liquid surface tension. Statistical analysis showed that the proposed correlation has an Average Absolute Relative Error (AARE) of 7.3 % and correlation coefficient of 92.2%. A

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 01 2012
Journal Name
The Iraqi Postgraduate Medical Journal
Isolation and identification of Malassezia species in patients with pityriasis versicolor
...Show More Authors

JM Karhoot, AA Noaimi, WF Ahmad, The Iraqi Postgraduate Medical Journal, 2012 - Cited by 7

View Publication