Preferred Language
Articles
/
bsj-5842
Ammonia Removal in Free-Surface Constructed Wetlands Employing Synthetic Floating Islands: Employing synthetic floating islands
...Show More Authors

Free water surface constructed wetlands (FSCWs) can be used to complement conventional waste water treatment but removal efficiencies are often limited by a high ratio of water volume to biofilm surface area (i.e. high water depth). Floating treatment wetlands (FTWs) consist of floating matrices which can enhance the surface area available for the development of fixed microbial biofilms and provide a platform for plant growth (which can remove pollutants by uptake).  In this study the potential of FTWs for ammoniacal nitrogen (AN) removal was evaluated using experimental mesocosms operated under steady-state flow conditions with ten different treatments (two water depths, two levels of FTW mat coverage, two different plant densities and a control, all replicated three times). A simple model was constructed as a framework for understanding N dynamics in each treatment.  The model was calibrated using data obtained from one treatment and validated independently for the other treatments. Specifically, we hypothesized that the nitrification and volatilization rate constants are inversely proportional to water depth and proportional to mat surface area. This allowed the relative magnitude of different removal mechanisms to be estimated.  The model was able to predict steady-state concentrations of AN and total oxidized nitrogen (TON) across the different treatments well (values for correlation in the regression between measured and predicted steady-state concentrations and RMSE were 0.88 and 0.40 mg N L-1 for AN, and 0.63 and 1.75 mg N L-1 for TON).  The results confirm that nitrification is the principal AN removal process, with maximum removal occurring in shallow systems with high matrix cover (i.e. a high ratio of biofilm surface area to water volume). Plant uptake was a relatively minor loss process compared to nitrification. Integrated experimental and model-based approach was found to be a useful tool to improve mechanistic understanding AN dynamics in FSCWs and system performance.

 

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Nov 30 2022
Journal Name
Desalination And Water Treatment
Removal of amoxicillin from wastewater by adsorption onto activated carbon prepared from sunflower seed hulls
...Show More Authors

In this study, the potential of adsorption of amoxicillin antibiotic (AMOX) from aqueous solutions using prepared activated carbon (AC) was studied. The used AC was prepared from an inexpensive and available precursor (sunflower seed hulls (SSH)) and activated by potassium hydroxide (KOH). The prepared AC was examined for its ability to remove AMOX from aqueous contaminated solutions and characterized with the aid of N2 -adsorption/desorption isotherm Brunauer–Emmett– Teller, scanning electron microscopy, energy-dispersive X-ray spectroscopy and Fourier-transform infrared. Zeta potential of the prepared activated carbon from sunflower seed hulls (SSHAC) were studied in relation to AMOX adsorption. The physical and chemical propert

... Show More
View Publication Preview PDF
Crossref (9)
Clarivate Crossref
Publication Date
Thu Oct 01 2020
Journal Name
Chemical Engineering And Processing - Process Intensification
Cobalt Removal from Simulated Wastewaters Using a Novel Flow-by Fixed Bed Bio-electrochemical Reactor
...Show More Authors

View Publication
Scopus (36)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Heliyon
Removal of copper by Azolla filiculoides and Lemna minor: phytoremediation potential, adsorption kinetics and isotherms
...Show More Authors

View Publication
Scopus (31)
Crossref (27)
Scopus Clarivate Crossref
Publication Date
Sat Jul 28 2018
Journal Name
Journal Of Engineering
Experimental Investigation for the Removal of Toxic Gases from Vehicle Exhaust using Non-Thermal Plasma
...Show More Authors

In this study, the use of non-thermal plasma theory to remove toxic gases emitted from a vehicle was experimentally investigated. A non-thermal plasma reactor was constructed in the form of a cylindrical tube made of Pyrex glass. Two stainless steel rods were placed inside the tube to generate electric discharge and plasma condition, by connecting with a high voltage power supply (up to 40 kV). The reactor was used to remove the contaminants of a 1.25-liter 4-cylinder engine at ambient conditions. Several tests have been carried out for a ranging speed from 750 to 4,500 rpm of the engine and varying voltages from 0 to 32 kV. The gases entering the reactor were examined by a gas analyzer and the gases concentration ratio

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Alexandria Engineering Journal
Calcium/iron-layered double hydroxides-sodium alginate for removal of tetracycline antibiotic from aqueous solution
...Show More Authors

Crossref (45)
Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Iranian Endodontic Journal
Smear Layer Removal from the Apical Third Using the Er,Cr:YSGG Photon-induced Photoacoustic Streaming
...Show More Authors

Scopus (13)
Scopus
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Removal Color Study of Toluidine Blue dye from Aqueous Solution by using Photo-Fenton Oxidation
...Show More Authors

The degradation of Toluidine Blue dye in aqueous solution under UV irradiation is investigated by using photo-Fenton oxidation (UV/H2O2/Fe+). The effect of initial dye concentration, initial ferrous ion concentration, pH, initial hydrogen peroxide dosage, and irradiation time are studied. It is found put that the removal rate increases as the initial concentration of H2O2 and ferrous ion increase to optimum value ,where in we get more than 99% removal efficiency of dye at pH = 4 when the [H2O2] = 500mg / L, [Fe + 2 = 150mg / L]. Complete degradation was achieved in the relatively short time of 75 minutes. Faster decolonization is achieved at low pH, with the optimal value at pH 4 .The concentrations of degradation dye are detected by spectr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jun 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Analysis of a Fixed Bed Absorber Used for the Removal of Pollutants from Water
...Show More Authors

View Publication Preview PDF
Publication Date
Tue Sep 30 2025
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Tetracycline removal from aqueous solution through photo-anodic oxidation process using rotating graphite cylinder anode
...Show More Authors

   In the present work, tetracycline (TC) was removed from a simulated wastewater through a new photo-anodic oxidation process with a rotating graphite cylinder anode. The effects of current density, pH, rotation speed, and NaCl addition were evaluated. The results confirmed that increasing the current density results in improving the removal of TC. However, increasing the current density beyond 5 mA/cm2 had little effect on TC removal. Results revealed that TC removal using photoanodic oxidation can be achieved at high performance with an initial pH of 5. Increasing or decreasing pH beyond this value has a negative effect on TC removal. Increasing rotation speed gave better performance for TC removal due to the increase in mass t

... Show More
View Publication
Crossref
Publication Date
Thu Jan 02 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
A Comparative Evaluation of Gutta-Percha and Sealer Removal of Rotary Niti File Retreatment Systems
...Show More Authors

Scopus