Endothelin-I (ET-I) is one of the potent vasoconstrictors secreted from endothelial cells when needed. Many studies revealed the elevation of serum ET-I with human diabetes and microangiopathies. Since insulin resistance is a case of mixed diabetic and pre-diabetic cases, many risk factors beyond obesity and inflammation are proposed. The current study aims to demonstrate the association between serum ET-I and asymmetric dimethylarginine (ADMA) and insulin resistance in type 2 diabetes mellitus (T2DM). Sera of 73 subjects were enrolled currently (control= 35 subjects, and 38 with T2DM for more than 7 years), aged (40-60) years old, with distinct body mass index (BMI) ≤ 25 for control volunteers and (BMI) ≥ 25 for obesity and diabetes patients. Peripheral serum ET-I and ADMA levels were significantly (P≤ 0.0001) higher in T2DM than the control subjects. Receiver operating characteristic curve analysis regarded ET-I and ADMA as good markers for T2DM disease and insulin resistance, correlations between ET-I and anthropometrics revealed a strong increase of urotensin-II (UII), ADMA, homeostatic model assessment for insulin resistance (HOMA-IR) and hemoglobin A1C (HbA1C) with an increase of ET-I. These results are supported by the data of multiple regression analysis, showing that HOMA-IR, HbA1C, UII, BMI, and mean arterial pressure (MAP) are related to ET-I independently. The endothelin-I and ADMA had a positive relationship with increase insulin resistance and may serve as prognostic and diagnostic clinical biomarkers of insulin resistance. Collectively, Therefore, these measurements could evaluate the incidence of DM, and help to better rise up the knowledge about the progression of DM complications.
The -mixing of - transition in Er 168 populated in Er)n,n(Er 168168 reaction is calculated in the present work by using a2- ratio method. This method has used in previou studies [4, 5, 6, 7] in case that the second transition is pure or for that transition which can be considered as pure only, but in one work we applied this method for two cases, in the first one for pure transition and in the 2nd one for non pure transitions. We take into accunt the experimental a2- coefficient for p revious works and -values for one transition only [1]. The results obtained are, in general, in agood agreement within associated errors, with those reported previously [1], the discrepancies that occur are due to inaccuracies existing
... Show MoreThe improvement in Direction of Arrival (DOA) estimation when the received signals impinge on Active-Parasitic Antenna (APA) arrays will be studied in this work. An APA array consists of several active antennas; others are parasitic antennas. The responses to the received signals are measured at the loaded terminals of the active element. The terminals of the parasitic element are shorted. The effect of the received signals on the parasites, i.e., the induced short-circuit current, is mutually coupled to the active elements. Eigen decomposition of the covariance matrix of the measurements of the APA array generates a third subspace in addition to the traditional signal and noise subspaces generated by the all-active ante
... Show MoreIs in this research review of the way minimum absolute deviations values based on linear programming method to estimate the parameters of simple linear regression model and give an overview of this model. We were modeling method deviations of the absolute values proposed using a scale of dispersion and composition of a simple linear regression model based on the proposed measure. Object of the work is to find the capabilities of not affected by abnormal values by using numerical method and at the lowest possible recurrence.
A newly developed analytical method was conducted for the determination of Ketotifen fumarate (KTF) in pharmaceuticals drugs via quenching of continuous fluorescence of 9(10H)-Acridone (ACD). The method was applied using flow injection system of a new homemade ISNAG fluorimeter with fluorescence measurements at ± 90◦ via 2×4 solar cell. The calibration graph was linear in the range of 1-45 mmol/L, with correlation coefficient r = 0.9762 and the limit of detection 29.785 µg/sample from the stepwise dilution for the minimum concentration in the linear dynamic ranged of the calibration graph. The method was successfully applied to the determination of Ketotifen fumarate in two different pharma
... Show MoreIn this work pyrazolin derivatives were prepared from the diazonium chloride salt of 4-aminobenzoic acid. Azo compounds were prepared from the reaction of an ethanolic solution of sodium acetate and calculated amount of active methylene compound namely, acetyl acetone to obtain the corresponding hydrazono derivative (1). Cyclocondensation reaction of compounds (1) with hydrazine hydrate and phenyl hydrazine in boiling ethanol affording the corresponding pyrazoline-5-one derivatives of 4-aminobenzoic acid (2,3). Then compound (3) was reacted with thionyl chloride to give the corresponding acid chloride derivative(4), followed by conversion into the corresponding acid hydrazide derivative (5) carboxylic acid thiosemicarbazide (11), esters
... Show MoreExtracorporeal Shock Wave Lithotripsy (ESWL) is the most commonplace remedy for kidney stone. Shock waves from outside the body frame are centered at a kidney stone inflicting the stone to fragment. The success of the (ESWL) treatment is based on some variables such as age, sex, stone quantity stone period and so on. Thus, the prediction the success of remedy by this method is so important for professionals to make a decision to continue using (ESWL) or tousing another remedy technique. In this study, a prediction system for (ESWL) treatment by used three techniques of mixing classifiers, which is Product Rule (PR), Neural Network (NN) and the proposed classifier called Nested Combined Classi
... Show More