Preferred Language
Articles
/
bsj-567
Evaluation of Laser Doping of Si from MCLT Measurement
...Show More Authors

The measurement of minority carrier lifetime (MCLT) ofp-n Si fabricated with aid of laser doping technique was reported. The measurement is achieved by using open circuit voltage decay (OCVD) technique. The experiment data confirms that the value of MCLT and proftle of Voc decay were very sensitive to the doping laser energy.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 25 2017
Journal Name
Biomedical And Pharmacology Journal
Diode Laser Versus Scalpel Gingivectomy
...Show More Authors

Background: different methods can be used to remove tissue during gingivectomy and produce a good gingival margin, the most common is the conventional gingivectomy which is done by the use of scalpel, now a day’s Laser is widely spread and can be used to perform surgeries. Materials and methods: 50 patients divided into two equal groups, Group 1 gingivectomy was done by Diode Laser, Group 2 gingivectomy was done by scalpel, plaque and gingival index were measured at 1st, 2nd and 3rd visit, swab were taken and sent foe detecting bacterial growth and biopsy were taken for histopathological examination. Group 1 show no significant differences in plaque and gingival means between the visits, the bacteriological examination showed no growth of

... Show More
View Publication
Crossref (8)
Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Biomedical & Pharmacology Journal
Diode Laser Versus Scalpel Gingivectomy
...Show More Authors

Different methods can be used to remove tissue during gingivectomy and produce a good gingival margin, the most common is the conventional gingivectomy which is done by the use of scalpel, now a day’s Laser is widely spread and can be used to perform surgeries. Materials and methods: 50 patients divided into two equal groups, Group 1 gingivectomy was done by Diode Laser, Group 2 gingivectomy was done by scalpel, plaque and gingival index were measured at 1st, 2nd and 3rd visit, swab were taken and sent foe detecting bacterial growth and biopsy were taken for histopathological examination. Group 1 show no significant differences in plaque and gingival means between the visits, the bacteriological examination showed no growth of bact

... Show More
Publication Date
Thu Jun 28 2018
Journal Name
Iraqi Journal Of Physics
Measurement of Percentage Depth Dose (PDD) for 6 MeV in water phantom and homogenous actual planning
...Show More Authors

Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied. Results show that high similarity between water phantom and actual planning for

... Show More
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Measurement of Percentage Depth Dose (PDD) for 6 MeV in water phantom and homogenous actual planning
...Show More Authors

Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied.
Results show that high similarity between water phantom and actual planning for th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Electric Power Systems Research
Analytical and measurement-based wideband two-port modeling of DC-DC converters for electromagnetic transient studies
...Show More Authors

Power-electronic converters are essential elements for the effective interconnection of renewable energy sources to the power grid, as well as to include energy storage units, vehicle charging stations, microgrids, etc. Converter models that provide an accurate representation of their wideband operation and interconnection with other active and passive grid components and systems are necessary for reliable steady state and transient analyses during normal or abnormal grid operating conditions. This paper introduces two Laplace domain-based approaches to model buck and boost DC-DC converters for electromagnetic transient studies. The first approach is an analytical one, where the converter is represented by a two-port admittance model via mo

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Dec 13 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
A New Measurement Scale for Evaluating Health-Related Quality of Life in Men with Prostate Cancer
...Show More Authors

Objectives: This study aimed to identify and study most properties of the specific and general health-related
quality-of-life (HRQoL) in prostate cancer patients, as well as creating a new measurement scale for assessing QoL
among prostate cancer patients.
Methodology: A cross sectional (descriptive) study was conducted to evaluate General Quality of life in patients
with prostate cancer. A sample of 100 prostate cancer patients from Al-Amal National hospital for cancer
management and Oncology Center in Baghdad Medical City. This study applied format of General World Health
Organization Quality of Life-BERF questionnaire. The methods used descriptive statistics to evaluate the General
QoL-Improvements, as well as inf

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 29 2022
Journal Name
International Ophthalmology
Comparison of corneal flap thickness predictability and architecture between femtosecond laser and sub-Bowman keratomileusis microkeratome in laser in situ keratomileusis
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Nov 10 2019
Journal Name
Journal Of Engineering And Applied Sciences
Fabrication and Properties of Ag<sub>2</sub>O/Si Heterojunction Solar Cell Pure and Doped (Sb, Sn and Se)
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Wed Sep 25 2024
Journal Name
Dentistry 3000
Maximum mouth opening measurement in relation to maximum bite force among children
...Show More Authors

Objective: This research aimed to study the relation between maximal bite force (MBF) and maximum mouth opening among 12-year-old school children. Methods: In this cross-sectional study, a total of 400 children aged 12 years (194 boys and 206 girls) were examined. The MBF for the right and left side, as well as the anterior region, were evaluated for all children. The MMO was measured using an electronic digital caliper. To analyze the data path analysis method was used. Results: Boys showed a higher MMO of 48.797 ± 6.500 than girls (46.710 ± 5.926 mm). The MMO increased with increasing MBF, with significant differences between females and males. Conclusion: The MMO was higher in boys than in girls. Gender plays a significant ro

... Show More
View Publication
Scopus Crossref
Publication Date
Sat Aug 01 2020
Journal Name
Jordan Journal Of Physics
Theoretical Simulation of Backscattering Electron Coefficient for SixGe1-x/Si Heterostructure as a Function of Primary Electron Beam Energy and Ge Concentration
...Show More Authors

Abstract: This study aims to investigate the backscattering electron coefficient for SixGe1-x/Si heterostructure sample as a function of primary electron beam energy (0.25-20 keV) and Ge concentration in the alloy. The results obtained have several characteristics that are as follows: the first one is that the intensity of the backscattered signal above the alloy is mainly related to the average atomic number of the SixGe1-x alloy. The second feature is that the backscattering electron coefficient line scan shows a constant value above each layer at low primary electron energies below 5 keV. However, at 5 keV and above, a peak and a dip appeared on the line scan above Si-Ge alloy and Si, respectively, close to the interfacing line

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref