Most studies indicated that the values of atmospheric variables have changed from their general rates due to pollution or global warming etc. Hence, the research indicates the changes of direct solar radiation values over a whole century i.e. from 1900 to 2000 depending on registered data for four cities, namely (Mosul - Baghdad - Rutba - Basra. Moreover, attemptsto correlate the direct solar radiation with the temperature values have been recorded over that period. The results showed that there is a decreasing pattern of radiation quantities over time throughout the study period, where the value of direct radiation over the city of Baghdad 5550 w/m2 was recorded in the year 1900, but this ratio decreased clearly to approximately 5400 w/m2 in the year 2000, which is perhaps due to the increase of general pollution rates in the atmosphere. The results also showed that the city of Rutba recorded the highest annual rate of radiation quantities, and Baghdad with Mosul recorded the lowest radiation ratios compared to the rest of the cities, in addition to that there was a large convergence of radiation ratios between them to some extent. The results showed that there is a sharp drop in radiation ratios, specifically in the years1980and 1990. As for the extent of the relationship for solar radiation with temperature levels throughout the study period, it was found that there is an inverse relationship between them, and this confirms that the cause of high temperatures is not because of increased solar radiation, but it may rather due to other reasons such as increased greenhouse gases.
In this paper a comparison of the experimental of evacuated tube solar water heater systems with and without mirror flat reflector. The aim of using the reflector to improve thermal efficiency, and the data gathered which are (temperature, solar irradiation and time) for three days were compared. the results from compared data the temperature lower increase in evacuated tube solar water heater system without reflector than the temperature increase in evacuated tube solar water heater system with reflector .The results show (53, 39, 35) % for three days respectively that the evacuated tube solar water heater system with reflector has higher thermal efficiencies than the results (47, 28, 30) % for three days respectively thermal efficiencies
... Show MoreThe article attempts to provide the theoretical fundamentals for the semiotic component of lacunae in a language. The definitions of the following notions have been represented: 1) lacunarity as a complex phenomenon that works in the modes of language, speech and speech behaviour; 2) lacuna as a gap, an empty space, which lacks something, which may be characteristic of a written work. The author of the article considers the main classes of lacunae, among which are: 1) generic lacunae, which reflect the absence of a common name for a class of objects; 2) species lacunae are the absence of specific names, names of individual types of objects or phenomena; 3) intralingual lacunae are found within the paradigms of one language; 4) interlanguage
... Show MoreInterleukin-6 (IL-6) is a proinflammatory cytokine implicated in the immunopathogenesis of tuberculosis (TB). TB is recognized worldwide as an important public health issue. To study the relationship between the age of patients with pulmonary TB and serum IL-6 levels, from the other hand, the severity of this disease with IL-6 levels. This study included 30 patients (16 female and 14 male) with pulmonary TB and 10 healthy persons (5 female and 5 male) as control group for comparison. An ELISA assay was used to quantify IL-6 in the sera. The results showed a significant increase of IL-6 levels with increase of age of patients, in (23-38) year old patients the IL-6 levels (median= 17.9 pg/ml, range 12.3-29.1), while in (50-70) year old patien
... Show MoreThis paper investigates the effect of magnetohydrodynamic (MHD) of an incompressible generalized burgers’ fluid including a gradient constant pressure and an exponentially accelerate plate where no slip hypothesis between the burgers’ fluid and an exponential plate is no longer valid. The constitutive relationship can establish of the fluid model process by fractional calculus, by using Laplace and Finite Fourier sine transforms. We obtain a solution for shear stress and velocity distribution. Furthermore, 3D figures are drawn to exhibit the effect of magneto hydrodynamic and different parameters for the velocity distribution.
In this work, chemical and thermal treatment were used to enhance silica extract on the purity of rice husk and to reduce the impurities associated with the extraction of silica. The thermal degradation of rice husk was studied. The characteristics and thermal degradation behavior of rice husk which investigated using thermogravimetric analyzer (TGA). Hydrochloric acid was used to soak the rice husk and the study of leaching influence is followed by XRF tests for samples before and after the combustion process. Acid treatment and combustion method seem to have a clear effect on silica purity. The pyrolysis processes were carried out at Laboratory temperature up to 650 oC in the presence of nitrogen gas flowing at 150 ml/min. The effect o
... Show MoreThin films of CdTe were prepared with thickness (500, 1000) nm on the glass substrate by vacuum evaporation technique at room temperature then treated different annealing temperatures (373,473,and 573)K for one hour. Results of the Hall Effect and the electrical conductivity of (I-V) characteristics were measured in darkness and light.at different annealing temperature results show that the thin films have ability to manufacture solar cells, and found that the efficient equal to (2.18%) for structure solar cell (Algrid / CdS / CdTe /glass/ Al) and the efficient equal to (1.12%) for structure solar cell (Algrid / CdS / CdTe /Si/ Al) with thick ness of (1000) nm with CdTe thin films at RT.
الخلاصة
تتناول هذه الورقة مخططات وسياسات الاستيطان في الضفة الغربية والقدس الشرقية منذ العام 1967، عبر سياسات قادها حزب العمل وأكملها حزب الليكود وكاديما وبقية الأحزاب الإسرائيلية، تلك السياسات التي استهدفت فرض السيطرة السياسية الكاملة على الأرض، وما نتج عن ذلك من سيطرة حصرية على الأرضوتقييد استخداماتها، ومحاصرة الوجود الفلسطيني والتضييق عليه، وتحويل مراكز ال
... Show MoreOf the new concepts introduced by the decree of the amendment of the French Civil Code No. 131-2016 issued on 10 February 2016, which raised a debate in jurisprudence both at the level of French jurisprudence or the Arab, the concept of (the content of the contract), which seems to have emerged from the appearance of new legal articles ( 1162-1171) is the cornerstone of the contract and the contract in the contract, the two pillars which, over the course of 200 years and a half, have been one of the main pillars of the codification of Napoleon. Is that the decree of amendment has already abandoned these two pillars, or most of what he did is a change in terminology while preserving the content of these two pillars implicitly, this is what w
... Show MoreIn the present work experiments were conducted to study the effect of solid loading (1,5 and 9 vol.%) on the enhancement of carbon dioxide absorption in bubble column at various volumetric gas flow rate (0.75, 1 and 1.5 m3/h) and absorbent concentration (caustic soda)( 0.1,0.5 and 1 M ). Activated carbon and alumina oxide (Al2O3) are used as solid particles. The Danckwerts method was used to calculate interfacial area and individual mass transfer coefficients during absorption of carbon dioxide in a bubble column. The results show that the absorption rate was increased with increasing volumetric gas flow rate, caustic soda concentration and solid loading. Mass transfer coefficient and interfac
... Show MoreIn this work an experimental study is performed to evaluate the thermal performance
of locally made closed loop solar hot water system using a shell and helical coiled tube
heat exchanger as a storage tank. Several measurements are taken include inlet and outlet
temperatures of both collectors and supply water and temperature distribution within the
storage tank. This is beside the water flow rate in both collectors and load cycle. The
main parameters of the system are obtained.