A spectrophotometric method has been proposed for the determination of two drugs containing phenol group [phenylephrine hydrochloride (PHP) and salbutamol sulphate (SLB)] in pharmaceutical dosage forms. The method is based on the diazotization reaction of metoclopramide hydrochloride (MCP) and coupling of the diazotized reagent with drugs in alkaline medium to give intense orange colored product (?max at 470 nm for each of PHP and SLB). Variable parameters such as temperature, reaction time and concentration of the reactants have been analyzed and optimized. Under the proposed optimum condition, Beer’s law was obeyed in the concentration range of 1-32 and 1-14 ?g mL-1 for PHP and SLB, respectively. The limit of detection (LOD) and limit of quantification (LOQ) for each of PHP and SLB were 0.60, 0.52 ?g mL-1 and 2.02, 1.72 ?g mL-1, respectively. No interference was observed from common excipients present in pharmaceutical preparations. The good correlation coefficients and low relative standard deviation assert the applicability of this method. The suggested method was further applied for the determinations of drugs in commercial pharmaceutical preparations, which was compared statistically with reference methods by means of t- test and F- test and were found not to differ significantly at 95% confidence level. The procedure was characterized by its simplicity with accuracy and precision.
The present study investigated the total content of phenolic compounds, antioxidant and antimicrobial activities of water extracts oat (Avena sativa) and basil (Ocimum basilicum), medicinal plants. The Folin-ciocalteu reagent assay was used to estimate the total phenolic content of plants extract. The antioxidant capacity of the plants extract was tested by ferric reducing/antioxidant power Assay (FRAP) and ferric reducing scavenging activity using DPPH method, and the antimicrobial activity was measured against [Staphylococcus epidermidis; Staphylococcus aureus; Proteus spp.; Klebsiella spp.; Escherichia coli; Candida albicans] as tester strains. The total phenolic content of Avena sativa and Ocimum basilicum extracts revealed that the
... Show MoreAbstractOBJECTIVES: To evaluate the long-term remission efficacy and safety of isotretinoin in the treatment of Behcet's disease (BD). PATIENTS and METHODS: This single-blind, controlled therapeutic study was conducted in the Department of Dermatology and Venereology at Baghdad Teaching Hospital from February 2011 to January 2012. Thirty patients with BD were included in this work. Each patient received isotretinoin 20 mg orally once daily for 3 months. They were assessed at week 2 and then monthly depending on the Clinical Manifestation Index (CMI) and to record any side effects. At week 12, isotretinoin was stopped and patients were given placebo therapy in a form of glucose capsules for another 3 months. RESULTS: Thirty patients were tre
... Show MoreThe development of a reversed phase high performance liquid chromatography fluorescence method for the determination of the mycotoxins fumonisin B1 and fumonisin B2 by using silica-based monolithic column is described. The samples were first extracted using acetonitrile:water (50:50, v/v) and purified by using a C18 solid phase extraction-based clean-up column. Then, pre-column derivatization for the analyte using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol was carried out. The developed method involved optimization of mobile phase composition using methanol and phosphate buffer, injection volume, temperature and flow rate. The liquid chromatographic separation was performed using a reversed phase Chromolith® RP-18e column
... Show MoreSolid dispersion (SD) formulation has attracted much attention due to its potential in enhancing dissolution performances of poorly soluble active pharmaceutical ingredients (API). Recently, a review on dissolution performances of SDs classifies the improvement into 3 categories, where 82 % of the studies showed improved bioavailability, 8 % showed reduced bioavailability and 10 % revealed similar bioavailability as compared to pure APIs. This indicates the inconsistent degrees of dissolution improvement of poorly soluble APIs in SD. Although a few factors related to the choice of carriers have been suggested to contribute to the dissolution improvement, however, the underlying factor determining the discrepancy in the degree of dissolution
... Show MoreSmoking is the inhalation of smoke tobacco burning that cover with narghile and cigarettes. There are a many problems result smoking such as, deterioration of health in general, undesirable social phenomenon, waste of money and time and stress.This study design to identify the effects of smoking narghile and cigarettes on levels of MPO, HCY and lipidprofil via determination of those parameters in cohort younger of Baghdad city. So to found the correlation coefficient of MPO and those parameters in groups that smoking cigarette and narghiledaily.As well as, to consider the MPO as biomarker to predictor coronary heart diseases. Increased levels of MPO, HCY total cholesterol (TC), triglyceride (TG), very low-density lipoprotein (VLDL) and low-
... Show MoreDetermination of the proportion of selected metal elements (Fe, Mn, Co, Cu, Cr, Ni, Mo, Pb, Cd ) using a flame absorption spectroscopy device and the spectroscopy of Graphite furnace, and Phenols so as Free Radical (NO3-, NO2-) using ultraviolet spectroscopy device in the industrial wastewater of Al-Dura (A) and AlNajaf (B) refinery before and after entering the treatment units, taking into consideration the sampling time Varying (more than separated) and setting the temperature during the drawing of the model and conducting a statistical study of the results reached
A cost-effective and efficient detector was created to conduct thorough turbidimetric measurements by reaction of Co (II) ion with calcium ferro cyanide to form bright green particulate, using the method of continuous flow injection analysis, the use of NAG-5SX1-1D-SSP Analyzer in determining cobalt (II) ion in a test for the validity of the new design. The NAG-5SX1-1D-SSP Analyzer is composed of five irradiation sources of white snow leds having the diameter of 10 mm with one solar cell of 55 mm length, 13.5 mm width. Using a selector switch to select the optimum voltage to be used which was 2.7 VDC. Under conditions of optimization, cobalt (II) ion was determined at 0.005–20 mmol. L–1(n = 23) while linearity dynamic range 0.005–7 mm
... Show MoreSynthesis, characterization and pharmaceutical studies of schiff base from 2-pyrrolidinone derivative and imidazole-2-carboxaldehyde and corresponding complexes with Metal (||)