Chronic myeloid leukemia (CML) is a myeloproliferative disorder characterized by the presence Philadelphia chromosome (Ph) which was created by a reciprocal translocation between chromosomes 9 and 22 (t [9;22] [q34;q11]. The approval of the 2nd generation TKI ( Nilotinib) takes the treatment of CML patients into new erea with more efficiency and mild to moderate adverse effects. This study was aimed at evaluation of molecular cytogenetic response by (FISH) for Nilotinib in Iraqi patients with assessment for electrolytes disturbances of Nilotinb by measuring a panel of electrolyte (Na+, K+, Ca++, PO4--- and Mg++) , where thirty Iraqi patients with CML who have resistance or no response to Imatinib treatment, attending to Baghdad Teaching Hospital/Hematology Department, have been submitted to this study. Blood samples have been taken pre and post starting treatment with Nilotinib, FISH study was done only for CML patients, while 30 normal healthy control volunteers submitted to the same panel of electrolytes measurements (Na+, K+, Ca++, PO4--- and Mg++) in addition to pre and post treatment Nilotinib patients. The results show out of 30 patients (17) males and (13) females with male to female ratio 1.3:1, FISH results for patients (pre and post) treatment mean±SD were(58.7%±26.2 % and 45.7%±29.9%) obviously significant with good cytogenetic response in resistance CML for Imatinib. Sodium levels in mmol/L pre, post treatment and control mean±SD were (139.2±6.9 , 142.4±9.2 and 140.4±2.52) respectively, with no significant difference between each other with P value > 0.05 in all comparisons. Potassium levels mean±SD in mmol/L results for patients (pre, post) and control were (4.6±0.69, 4.3±0.68 and 4.46±0.76) respectively, with no significant difference between each other with P value > 0.05 in all comparisons. Calcium levels in mg/dL results for patients (pre, post) and control as mean±SD were (8.68 ±1.68, 8.1±1.72 and 9.12±0.38) respectively with no significant differences except between post treatment and control group with P value > 0.05 in all comparisons. Phosphate levels in mg/dL results for patients (pre, post) and control as mean±SD were (2.5±0.84, 2.95±1.04 and 3.4±0.49) respectively with significant difference with P value < 0.05 in all comparisons. Magnesium levels in mg/dL results for patients pre, post and control as mean±SD were (1.93±0.34, 2.06±0.44 and 2.1±0.34) respectively with no significant difference between each other with P value > 0.05 in all comparisons. This study sheds a light on the molecular cytogenetic response for CML patients who have already resistance to Imatinib and Nilotinib that has much more potent effect as approved by studies and this study has used FISH technique. This study emphasizes on the importance of evaluation of electrolyte panel for CML patients before starting Nilotinib study taking in to consideration if these patients are already receiving Imatinib which can also affect bone metabolism and calcium and phosphate levels.
|
In this work, an experimental investigation has been done for heat transfer by natural-convection through a horizontal concentric annulus with porous media effects. The porous structure in gap spacing consists of a glass balls and replaced by plastic (PVC) balls with different sizes. The outer surface of outer tube is isothermally cooled while the outer surface of inner tube is heated with constant heat flux condition. The inner tube is heated with different supplied electrical power levels. Four different radius ratios of annulus are used. The effects of porous media material, particles size and annulus radius ratio on heat dissipation in terms of average Nusselt number have been analyzed. |
In this research the behavior of reinforced concrete columns with large side openings under impact loads was studied. The overall cross sectional dimensions of the column specimens used in this research were (500*1400) mm with total height of (14000) mm. The dimensions of side openings were (600*2000) mm. The column was reinforced with (20) mm diameter in longitudinal direction, while (12) mm ties were used in the transverse direction. The effect of eccentric impact loads on the horizontal and vertical displacement for this column was studied. &
... Show MoreIt is suitable to use precast steel-concrete composite beams to quickly assemble a bridge or a building, particularly in isolated regions where cast-in-situ concrete is not a practical option. If steel-concrete composite beams are designed to allow demountability, they can also be extremely useful in the aftermath of natural disasters, such as earthquakes or flooding, to replace damaged infrastructure. Furthermore, rapid replacement of slabs is extremely beneficial in case of severe deterioration due to long-term stressors such as fatigue or corrosion. The only way to rapidly assemble and disassemble a steel-concrete composite structure is to use demountable shear connectors to connect/disconnect the steel beams to/from the concrete slab. I
... Show MoreMetal (III) and (II) coordination compounds of o- phenylenediamine, oxalic acid dihydrate and 8-hydroxyquinoline were synthesized for mixed ligand complexes and characterized using FT-IR, UV-Vis and mass spectra, atomic absorption, elemental analysis, electric conductance and magnetic susceptibility measurements. In addition, thermal behavior (TGA) of the metal complexes (1-6) showed good agreement with the formula suggested from the analytical data. The stoichiometric reaction between the metal (III) and (II) ions with three various ligands in molar ratio at aqueous ethyl alchol for (1:1:1:1) (M: O-PDA: OA: 8-HQ) [where M = Cr+3, Mn+2, Co+2, Ni+2. Cu+2 and Zn+2; O-PDA = O-Phenylenediamine; OA = Oxalic acid and 8-HQ = 8-Hydroxyquinoline]. R
... Show MoreGlass Fiber Reinforced Polymer (GFRP) beams have gained attention due to their promising mechanical properties and potential for structural applications. Combining GFRP core and encasing materials creates a composite beam with superior mechanical properties. This paper describes the testing encased GFRP beams as composite Reinforced Concrete (RC) beams under low-velocity impact load. Theoretical analysis was used with practical results to simulate the tested beams' behavior and predict the generated energies during the impact loading. The impact response was investigated using repeated drops of 42.5 kg falling mass from various heights. An analysis was performed using accelerometer readings to calculate the generalized inertial load
... Show MoreIn the current study, synthesis and characterization of silver nanoparticles (AgNPs) before and after functionalization with ampicillin antibiotic and their application as anti-pathogenic agents towards bacteria were investigated. AgNPs were synthesized by a green method from AgNO3 solution with glucose subjected to microwave radiation. Characterization of the nanoparticles was conducted using UV-Vis spectroscopy, scanning electron microscopy (SEM), zeta potential determination and Fourier transform infrared (FTIR) spectroscopy. From SEM analysis, the typical silver nanoparticle particle size was found to be 30 nm and Zeta potential measurements gave information about particle stability. Analysis of FTIR patterns and UV-VIS spectroscopy con
... Show MoreUsing an environmentally friendly chemical process, a novel nanocomposite consisting of reduced graphene oxide (rGO) and silver(I) oxide (Ag2O) nanoparticles was successfully synthesized in this work, and its optical properties along with photoelectric performance were investigated. Ag2O is a narrow-bandgap p-type semiconductor with strong visible light response but exhibits poor carrier separation and structural instability during exposure to radiation. In order to overcome shortcomings encountered with Ag2O, rGO was used as a conductive support to produce rGO@Ag2O nanocomposites with improved electronic interactions. Various characterization tests, including energy-dispersive X-ray spectroscopy (EDXS), field emission scanning electron mic
... Show MoreThe economical units in the world face great and rapid challenges in all aspects, a matter that requires facing these challenges throughout continuous improving and developing in their performance to keep their competitive position "place".
The Benchmarking Technique is one of the modern managerial tools that are proved to be successful in application throughout making continuous comparisons between products or services and the best – performance levels the compete with it . This is achieved to develop its performance and give it the competitive criterion with which it faces its competitors.
... Show More
Objective: To identify of the effect of the different concentrations of the special liquid (for mixing the investment, Gilvest)
and mixed with water/powder ratio on setting time of phosphate–bonded investment.
Method and materials: The present study is (60) specimens made from phosphate bonded investment divided into (4)
groups (control and experimental groups), (15) specimens for each group. The Gillmore needle device is used to setting
time of phosphate bonded investment mixed with different concentration of Gilvest and water.
Results: Showed that there is a high significant difference (P<0.01) between each groups in the ANOVA test and a
significant difference (P<0.05) between the group (A) and control group i