Chronic myeloid leukemia (CML) is a myeloproliferative disorder characterized by the presence Philadelphia chromosome (Ph) which was created by a reciprocal translocation between chromosomes 9 and 22 (t [9;22] [q34;q11]. The approval of the 2nd generation TKI ( Nilotinib) takes the treatment of CML patients into new erea with more efficiency and mild to moderate adverse effects. This study was aimed at evaluation of molecular cytogenetic response by (FISH) for Nilotinib in Iraqi patients with assessment for electrolytes disturbances of Nilotinb by measuring a panel of electrolyte (Na+, K+, Ca++, PO4--- and Mg++) , where thirty Iraqi patients with CML who have resistance or no response to Imatinib treatment, attending to Baghdad Teaching Hospital/Hematology Department, have been submitted to this study. Blood samples have been taken pre and post starting treatment with Nilotinib, FISH study was done only for CML patients, while 30 normal healthy control volunteers submitted to the same panel of electrolytes measurements (Na+, K+, Ca++, PO4--- and Mg++) in addition to pre and post treatment Nilotinib patients. The results show out of 30 patients (17) males and (13) females with male to female ratio 1.3:1, FISH results for patients (pre and post) treatment mean±SD were(58.7%±26.2 % and 45.7%±29.9%) obviously significant with good cytogenetic response in resistance CML for Imatinib. Sodium levels in mmol/L pre, post treatment and control mean±SD were (139.2±6.9 , 142.4±9.2 and 140.4±2.52) respectively, with no significant difference between each other with P value > 0.05 in all comparisons. Potassium levels mean±SD in mmol/L results for patients (pre, post) and control were (4.6±0.69, 4.3±0.68 and 4.46±0.76) respectively, with no significant difference between each other with P value > 0.05 in all comparisons. Calcium levels in mg/dL results for patients (pre, post) and control as mean±SD were (8.68 ±1.68, 8.1±1.72 and 9.12±0.38) respectively with no significant differences except between post treatment and control group with P value > 0.05 in all comparisons. Phosphate levels in mg/dL results for patients (pre, post) and control as mean±SD were (2.5±0.84, 2.95±1.04 and 3.4±0.49) respectively with significant difference with P value < 0.05 in all comparisons. Magnesium levels in mg/dL results for patients pre, post and control as mean±SD were (1.93±0.34, 2.06±0.44 and 2.1±0.34) respectively with no significant difference between each other with P value > 0.05 in all comparisons. This study sheds a light on the molecular cytogenetic response for CML patients who have already resistance to Imatinib and Nilotinib that has much more potent effect as approved by studies and this study has used FISH technique. This study emphasizes on the importance of evaluation of electrolyte panel for CML patients before starting Nilotinib study taking in to consideration if these patients are already receiving Imatinib which can also affect bone metabolism and calcium and phosphate levels.
KE Sharquie, GA Ibrahim, AA Noaimi, HK Hamudy, Journal of the Saudi Society of Dermatology & Dermatologic Surgery, 2011 - Cited by 16
Patients with renal failure in the final stages undergo the treatment by hemodialysis. Hemodialysis is used to reinstate the intracellular and extracellular fluid environment, by propagation of molecules in solution through a semipermeable membrane along an electrochemical concentration gradient. Blood catching in the dialysis machine and the recurrent phlebotomy may lead to losing about 1-3 g of iron per year. Prohepcidin hormone is an acute phase protein (type II) that plays a major role in the systemic iron irregularities as it is a mediator of anemia in inflammation and regulator of iron metabolism. This study aims to evaluate the effect of hemodialysis on iron hemostasis and its relationship with prohepcidin as an inflammatory mark
... Show MoreIn this research, the effect of reinforcing epoxy resin composites with a filler derived from chopped agriculture waste from oil palm (OP). Epoxy/OP composites were formed by dispersing (1, 3, 5, and 10 wt%) OP filler using a high-speed mechanical stirrer utilizing a hand lay-up method. The effect of adding zinc oxide (ZnO) nanoparticles, with an average size of 10-30 nm, with different wt% (1,2,3, and 5wt%) to the epoxy/oil palm composite, on the behavior of an epoxy/oil palm composite was studied with different ratios (1,2,3, and 5wt%) and an average size of 10-30 nm. Fourier Transform Infrared (FTIR) spectrometry and mechanical properties (tensile, impact, hardness, and wear rate) were used to examine the composites. The FTIR
... Show MoreObjective: The aim of the study to evaluate the nursing care management for diabetes mellitus patient
with total hip replacement after fractured hip.
Methodology: A field study carried out on patients with diabetes mellitus and have total hip
replacement after fractured hip in orthopedic ward at the hospital of surgical specialization (malefemale)during
January 2002 to January 2003.Physical and psychological nursing
assessment
immediately after the surgery was done for the both subjects (control and experimental) and then a
scientific management with daily nursing care were provided to the experimental subject with daily
nursing care to the patient condition by using a scientific and practical methods and leave th
In this research, the effect of reinforcing epoxy resin composites with a filler derived from chopped agriculture waste from oil palm (OP). Epoxy/OP composites were formed by dispersing (1, 3, 5, and 10 wt%) OP filler using a high-speed mechanical stirrer utilizing a hand lay-up method. The effect of adding zinc oxide (ZnO) nanoparticles, with an average size of 10-30 nm, with different wt% (1,2,3, and 5wt%) to the epoxy/oil palm composite, on the behavior of an epoxy/oil palm composite was studied with different ratios (1,2,3, and 5wt%) and an average size of 10-30 nm. Fourier Transform Infrared (FTIR) spectrometry and mechanical properties (tensile, impact, hardness, and wear rate) were used to examine the composites. The
... Show MoreIn this work, an inventive photovoltaic evaporative cooling (PV/EC) hybrid system was constructed and experimentally investigated. The PV/EC hybrid system has the prosperous advantage of producing electrical energy and cooling the PV panel besides providing cooled-humid air. Two cooling techniques were utilized: backside evaporative cooling (case #1) and combined backside evaporative cooling with a front-side water spray technique (case #2). The water spraying on the front side of the PV panel is intermittent to minimize water and power consumption depending on the PV panel temperature. In addition, two pad thicknesses of 5 cm and 10 cm were investigated at three different water flow rates of 1, 2, and 3 lpm. In Case #1,
... Show More