The current study deals with estimating the protein concentration and the effect of fish weight on protein concentration values in red and white muscles in two different regions ( R1 : Anterior region lies 2 cm behind the head and R2: posterior region lies 2cm from caudal fin (in two types of bony fish, namely common carp (Cyprinus carpio) and Nile tilapia (Oreochromis niloticus). Samples were collected from Karmat Ali river- north of Basrah between October 2019 and February 2020. The protein was extracted using protein extraction buffer, the current study show that the average of protein concentration in red muscles of Nile tilapia ranged between 7.74-7.4 mg / ml and ( 6.8-8.85 mg / ml) in R1 and R2 region respectively, while it ranged between 173-334 mg / ml and 127-253 mg / ml in R1and R2 region in white muscles, respectively. In Carp, protein concentration for red muscles was 7.19-9.10 mg / ml and 6.87-8.41 mg / ml in R1 and R2 regions, respectively. On the other hand, protein concentration in white muscles ranged between 98.7-250.2 mg / ml and 61.5-214.1 mg / ml in both R1 and R2 regions respectively. The statistical analysis results of the protein concentration in the red and white muscles in the body regions indicated that there was a significant difference(P<0.05) and non- significant difference (P>0.05) between the protein concentration in red and white muscles in the studied species ,The current study concluded that white muscles contain a higher protein concentration than red muscles and that weight gain has a significant effect on protein concentration in white muscles.
In this study, NAC-capped CdTe/CdS/ZnS core/double shell QDs were synthesized in an aqueous medium to investigate their utility in distinguishing normal DNA from mutated DNA extracted from biological samples. Following the interaction between the synthesized QDs with DNA extracted from leukemia cases (represents damaged DNA) and that of healthy donors (represents undamaged DNA), differential fluorescent emission maxima and intensities were observed. It was found that damaged DNA from leukemic cells DNA-QDs conjugates at 585 nm while intact DNA (from healthy subjects) DNA–QDs conjugates at 574 nm. The obtained results from the optical analyses indicate that the prepared QDs could be utilized as probe for detecting disrupted DNA th
... Show MoreThis study analyses six political cartoons selected based on their relevance to current Iraqi political issues, specifically the period between 2005 and 2015, from American online newspapers (calgecartooms.com). The selection criteria included the cartoons' satirical elements, visual rhetoric, and their ability to engage with themes such as power dynamics, social issues, and public opinion. It sheds light on how these cartoons can function as mediators of meanings between the cartoonists and the readers. The data is examined using multimodal discourse analysis (MDA), which combines language study with the analysis of other visual elements, like colors, gestures, and images, to understand meaning (O’Halloran et al., 2011). The Visual Socia
... Show MoreThe production of power using the process of pressure–retarded osmosis (PRO) has been studied both experimentally and theoretically for simulated sea water vs. river water and deionized water under two cases: the first is for simulated real conditions of sea water and river water and second under low brine solution concentration to examine the full profile of the power- pressure. The influence of concentration polarization (CP) on water flux has been examined as well.
A new, simple and sensitive method was used forevaluation of propranolol withphosphotungstic acidto prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between propranolol and phosphotungstic acid in an aqueous medium to obtain a yellow precipitate. Optimum parameters was studied to increase the sensitivity for developed method. A linear range for calibration graph was 0.007-13 mmol/L for cell A and 5-15 mmol/L for cell B, and LOD 207.4792 ng/160 µL and 1.2449 µg/160 µL respectively to cell A and cell B with correlation coefficient (r) 0.9988 for cell A, 0.9996 for cell B, RSD% was lower than 1%, (n=8) for the
... Show MoreAromatic Schiff-bases are known to have antibacterial activity, but most of these compounds are sparingly soluble in water. The present work describes the synthesis of new Schiff-bases derived from branched aminosugars. Treatment of 3-Amino-3-Cyano-3-Deoxy-1,2:5,6-Di-O-Isopropylene-α-D-Allofuranose (1) with the aldehydes (2) under reflux in methanol afforded the Schiff-bases (3) in good yields. The new Schiff-bases were in accord with their NMR, IR spectral data and elemental analysis.
The current study aimed the syntheses and characterizations of Gold nanoparticles (Au NPs) using a laser ablation Q-switched Nd: YAG laser with a wave-length of 355 nm at a variety of laser pulse energies (E) and deposited on porous silicon (PS). Optical emission spectrometer was used to diagnosed medium air to study gold plasma characteristics and prepared Au nanoparticles. The laser pulse energy influence has been studied on the plasma characteristics in air. The data showed the emergence of the ionic (Au II) spectral emission lines in the gold plasma emission spectrum. XRD has been utilized to examine structural characteristics. Moreover, AFM results 37.2 nm as the mean value of the diameter that is coordinated in a shape similar to the
... Show Morea laser ablation Q-switched Nd: YAG laser with a wave-length of 355 nm at a variety of laser pulse energies (E) and deposited on porous silicon (PS). Optical emission spectrometer was used to diagnosed medium air to study gold plasma characteristics and prepared Au nanoparticles. The laser pulse energy influence has been studied on the plasma characteristics in air. The data showed the emergence of the ionic (Au II) spectral emission lines in the gold plasma emission spectrum. XRD has been utilized to examine structural characteristics. Moreover, AFM results 37.2 nm as the mean value of the diameter that is coordinated in a shape similar to the rod that appears for Au NPs, in addition to that, TEM has been an indication of the fact that syn
... Show More