Preferred Language
Articles
/
bsj-5280
Using of Index Biological Integrity of Phytoplankton (P-IBI) in the Assessment of Water Quality in Don River Section
...Show More Authors

       The multimetric Phytoplankton Index of Biological Integrity (P-IBI) was applied throughout Rostov on Don city (Russia) on 8 Locations in Don River from April – October 2019. The P-IBI is composed from seven metrics: Species Richness Index (SRI), Density of Phytoplankton and total biomass of phytoplankton and Relative Abundance (RA) for blue-green Algae, Green Algae, Bacillariophyceae and Euglenaphyceae Algae. The average P-IBI values fell within the range of (45.09-52.4). Therefore, water throughout the entire study area was characterized by the equally "poor" quality. Negative points of anthropogenic impact detected at the stations are: Above the city of Rostov-on-Don (1 km, higher duct Aksai) was 38.57 in June, the lower inflow of the Temernik river  which was 38.57- 41.42 in summer and below the spillway was 38.57 -34.28 in August. At these stations, samples with P-IBI values more than 56, characterizing water quality as "Fair", were not found in any of the observations. The negative effect on the water at the stations may be due to the influence of the closely located Aksai city and the impact of the Temernik River. In Russia P-IBI have not been used yet, so this study can be considered as the first study that’s conducted to assess the environmental status of the Don River by using the phytoplankton index of Biological Integrity and has developed scoring criteria of the Don River (P-IBI) and other watercourses of the south of Russia. The continuous monitoring relaying on the selection of the most suitable metrics score is recommended.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Oct 01 2023
Journal Name
Baghdad Science Journal
Biological peculiarities of Leucozonella retteri
...Show More Authors

The aim of the research is to study the biology, life cycles, distribution and structure of the reproductive organ of Leucozonella retteri in natural conditions. Zoological and malacological methods are used in the work. The collection of the material was carried out according to A.A. Shileiko method. According to the results of the conducted studies, the differences between Leucozonella retteri and other species in the structure of the reproductive organ were manifested in the following. The lower part of the sperm is straight, the ovary is slightly curved. The paw pad is 8, located in 4x2 positions. The stylophore is large spherical. The vagina is cylindrical, its length is 5-6 times greater than the width. The penis is large and conve

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Biodiversity Index value of benthic invertebrates' community in relation with variation of some environmental properties in Rivers Tigris and Diyala within Baghdad city.
...Show More Authors

This study was carried out to determine the effects of some environmental variables on biodiversity index value of benthic invertebrates' community in samples that collected monthly from two adjacent sites nearby the confluence of Tigris and Diyala rivers within Baghdad city that’s from November 2007 - October 2008. Results showed differences in chemical and physical characteristics for each river. Where the annual averages of these characteristics in Rivers Tigris and Diyala respectively for: water temperature (20, 19) Cº, pH (8, 8), Dissolved oxygen DO(8,4 ) mg/l , EC(1152,2979)µc/cm , Turbidity (28,74) NTU, Total Hardness of CaCO3 (485,823)mg/l, and finally NO3 (4,6)mg/l. Concerning the biological groups, included types of Insect

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 31 2022
Journal Name
Mathematical Modelling Of Engineering Problems
Experimental and Numerical Study of Open Channel Flow with T-Section Artificial Bed Roughness
...Show More Authors

Experimental and numerical studies have been conducted on the effects of bed roughness elements such as cubic and T-section elements that are regularly half-channel arrayed on one side of the river on turbulent flow characteristics and bed erosion downstream of the roughness elements. The experimental study has been done for two types of bed roughness elements (cubic and T-section shape) to study the effect of these elements on the velocity profile downstream the elements with respect to different water flow discharges and water depths. A comparison between the cubic and T-section artificial bed roughness showed that the velocity profile downstream the T-section increased in smooth side from the river and decrease in the rough side

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Civil Engineering Journal
Flexural Behavior of Composite GFRP Pultruded I-Section Beams under Static and Impact Loading
...Show More Authors

In this study, the effect of glass fiber reinforced polymer (GFRP) section and compressive strength of concrete in composite beams under static and low velocity impact loads was examined. Modeling was performed and the obtained results were compared with the test results and their compatibility was evaluated.‎ Experimental tests of four composite beams were carried out, where two of them are control specimen with 20 MPa compressive strength of concrete deck slab and 50 MPa for other. Bending characteristics were affected by the strength of concrete under impact loading case, as it increased maximum impact force and damping time at a ratio of 59% and reduced the damping ratio by 47% compared to the reference hybrid beam. Under stat

... Show More
Scopus (23)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2014
Journal Name
Journal Of Water Resource And Protection
Evaluating Water Stability Indices from Water Treatment Plants in Baghdad City
...Show More Authors

View Publication
Crossref (33)
Crossref
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
An Environmental Study of Epiphytic Algae on Ceratophyllum demersum in Tigris River within Baghdad City, Iraq
...Show More Authors

The present study was conducted in the Tigris River within Baghdad (University of Baghdad campus). The study included some physicochemical parameters and qualitative of epiphytic algae on the host plant (Ceratophyllum demersum) during summer season 2013. The results revealed that the study area was alkaline, hard and oxygenated water. A total of 105 taxa of epiphytic algae was identified. Bacillariophyceae diatoms composed 44.7% of the total and were represented by 42.4% of the order Pennales and 1.9 %of the order Centrales. Chlorophyceae composed 32.3%, followed by Cyanophyceae composed 22.8 % of the total. The total number of epiphytic algae was fluctuated among the study period. Most of the identified algae were benthos type and a few

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Mar 28 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Different Electrodes Connections in Electrocoagulation of Synthetic Blow down Water of Cooling Tower
...Show More Authors

In this research, the performance of electrocoagulation (EC) using aluminum (Al) electrodes with   Monopolar- parallel (MP-P), and bipolar - series (BP-S) arrangement for simultaneous removal of dissolved silica, and hardness ions (calcium, and magnesium) from synthetic blowdown water of cooling tower were investigated. The effects of current density, initial pH and time of electrolysis on the removal efficiency were studied in a batch stirred unit to find out the best-operating conditions. The obtained results for each target species are evidence that BP-S approach is the best for both electrodes configuration operated at a Current density of 1mA/cm2 through 30 min of treatment and pH=10 with the removal of

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Thu May 12 2016
Journal Name
Biochemistry
Probing the Role of Active Site Water in the Sesquiterpene Cyclization Reaction Catalyzed by Aristolochene Synthase
...Show More Authors

View Publication
Crossref (28)
Crossref
Publication Date
Fri Mar 15 2019
Journal Name
Al-khwarizmi Engineering Journal
Theoretical Prediction of Optimum Chilled Water Distribution Configuration in Air Conditioning Terminal Unit
...Show More Authors

 The distribution of chilled water flow rate in terminal unit is a major factor used to evaluate the performance of central air conditioning unit. In this work, a theoretical chilled water distribution in the terminal units has been studied to predict the optimum heat performance of terminal unit. The central Air-conditioning unit model consists of cooling/ heating coil (three units), chilled water source (chiller), three-way and two-way valve with bypass, piping network, and pump. The term of optimization in terminal unit ingredient has two categories, the first is the uniform of the water flow rate representing in statically permanents standard deviation (minimum value) and the second category is the maximum heat transfer rate fro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
Health-Related Quality of Life in Diabetic Women with Comparing Obese & Normal weight
...Show More Authors

Background: The prevalence of both obesity & diabetes are increasing all over the world & more in women.  They have a negative impact not only on morbidity & mortality but also on quality of life.

Objectives: To assess the HRQoL with a specific comparison between obese & normal weight among wo

... Show More
View Publication Preview PDF
Crossref (1)
Crossref