Preferred Language
Articles
/
bsj-526
Performance evolution of a hybrid thermal solar air conditioning system and compare it with a traditional system according to Iraq weather
...Show More Authors

In a hybrid cooling solar thermal systems , a solar collector is used to convert solar energy into heat energy in order to super heat the refrigerant leaving the compressor, and this process helps in the transformation of refrigerant state from gaseous state to the liquid state in upper two-thirds of the condenser instead of the lower two-thirds such as in the traditional air-conditioning systems and this will reduce the energy needed to run the process of cooling .In this research two systems with a capacity of 2 tons each were used, a hybrid air-conditioning system with an evacuated tubes solar collector and a traditional air-conditioning system . The refrigerant of each type was R22.The comparison was in the amount of energy and current consumption of the two systems at the same operating conditions. The energy consumed and the current of the hybrid system were less than the traditional air-conditioning system by 12% and 28.6% respectively, which means that there is a saving in the energy and current consumption as a result of the use of the solar thermal collector.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Feb 27 2021
Journal Name
Journal Of Engineering
Design and Simulation of a controller for Double Fed Induction Generator turbine Utilized Solar Up Draft Tower
...Show More Authors

This paper introduces a complete design and simulation of a controller for the double fed induction generator (DFIG) turbine. The work also included the solar updraft tower (SUT) design to supply Al-Mahmoudia hospital in Baghdad/Iraq. The design includes the daily average load estimation, annual solar irradiance and, temperature monitoring, and logging.

According to the data obtained from the Ministry of Science and Technology, Baghdad has low wind speed. Therefore, the (SUT) has been designed to generate electrical power depending on the difference between the external and internal air temperature. The temperature difference will generate a suitable airspeed to drive the wind turbine, connected to the proposed (DFIG) generators

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
An Experimental Study of the Effect of Vortex Shedding on Solar Collector Performance
...Show More Authors

In this work, the effect of vortex shedding on the solar collector performance of the parabolic trough solar collector (PTSC) was estimated experimentally. The effect of structure oscillations due to wind vortex shedding on solar collector performance degradation was estimated. The performance of PTSC is evaluated by using the useful heat gain and the thermal instantaneous efficiency. Experimental work to simulate the vortex shedding excitation was done. The useful heat gain and the thermal efficiency of the parabolic trough collector were calculated from experimental measurements with and without vortex loading. The prototype of the collector was fabricated for this purpose. The effect of vortex shedding at different operation condition

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 25 2019
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
MEASUREMENT OF CHEMICAL AND PHYSICAL PROPERTIES IN SOME MINERAL WATER SAMPLES FILLED IN THE MARKETS OF THE PROVINCE OF NAJAF AND COMPARE WITH THE IRAQI AND INTERNATIONAL RATIOS.: MEASUREMENT OF CHEMICAL AND PHYSICAL PROPERTIES IN SOME MINERAL WATER SAMPLES FILLED IN THE MARKETS OF THE PROVINCE OF NAJAF AND COMPARE WITH THE IRAQI AND INTERNATIONAL RATIOS.
...Show More Authors

In this research, a selection of some mineral water was selected on the basis of being the most marketed by the owners of shops in Najaf province, with six types, where daily samples of this water were taken by 50 ml for two months from (1/11/2018 -1/1/2019). The following ions concentrations were measured (Br-, Cl-, F-, NO3-, SO42-, Na+, K+, Ca2+, Mg2+), pH and the electrical conductivity were measured and the results were compared with the allowable rates according to the international organizations. It was noted that they conform to international and Iraqi standards.

View Publication Preview PDF
Publication Date
Tue Oct 15 2024
Journal Name
Civileng
Structural Performance of a Hollow-Core Square Concrete Column Longitudinally Reinforced with GFRP Bars under Concentric Load
...Show More Authors

Concrete columns with hollow-core sections find widespread application owing to their excellent structural efficiency and efficient material utilization. However, corrosion poses a challenge in concrete buildings with steel reinforcement. This paper explores the possibility of using glass fiber-reinforced polymer (GFRP) reinforcement as a non-corrosive and economically viable substitute for steel reinforcement in short square hollow concrete columns. Twelve hollow short columns were meticulously prepared in the laboratory experiments and subjected to pure axial compressive loads until failure. All columns featured a hollow square section with exterior dimensions of (180 × 180) mm and 900 mm height. The columns were categorized into

... Show More
View Publication
Scopus (4)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Wed May 01 2024
Journal Name
Journal Of Drug Delivery Science And Technology
Antibacterial and wound healing performance of a novel electrospun nanofibers based on polymethyl-methacrylate/gelatin impregnated with different content of propolis
...Show More Authors

View Publication
Scopus (12)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
Parabola Dish and Cassegrain Concentrators to Improve Solar Cell Conversion Efficiency
...Show More Authors

New designs of solar using ray tracing program, have been presented for improved the performance and the out put power of the silicon solar cell, as well as reducing the cost of system working by solar energy. Two dimensional solar concentrator (Fresnel lenses) and three dimensional concentrators (parabola dish and cassegrain) were used as concentrator for photovoltaic applications (CPV). The results show that the performance efficiency and out power for crystalline silicon solar cells are improved.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Feb 01 2021
Journal Name
International Journal Of Electrical And Computer Engineering (ijece)
Differential evolution detection models for SMS spam
...Show More Authors

With the growth of mobile phones, short message service (SMS) became an essential text communication service. However, the low cost and ease use of SMS led to an increase in SMS Spam. In this paper, the characteristics of SMS spam has studied and a set of features has introduced to get rid of SMS spam. In addition, the problem of SMS spam detection was addressed as a clustering analysis that requires a metaheuristic algorithm to find the clustering structures. Three differential evolution variants viz DE/rand/1, jDE/rand/1, jDE/best/1, are adopted for solving the SMS spam problem. Experimental results illustrate that the jDE/best/1 produces best results over other variants in terms of accuracy, false-positive rate and false-negative

... Show More
View Publication
Scopus (9)
Crossref (3)
Scopus Crossref
Publication Date
Fri Dec 30 2011
Journal Name
Al-kindy College Medical Journal
Etiologies of chronic cough in adult patients: Is it hard to be diagnosed?
...Show More Authors

Background: Chronic cough is often the key
symptom not only of chronic pulmonary diseases
but for other important extrapulmonary
pathologies, in particular upper airway and
gastrointestinal diseases.
Objective: This study was designed to
determine the etiology of chronic cough and the
usefulness of the available diagnostic tests in
reaching its causes.
Methods: One hundred patients presenting with
chronic cough at Baghdad Teaching Hospital
Outpatient Clinic were enrolled in this study. The
patients underwent a full clinical interview,
physical examination with indicated diagnostic
test(s) (such as chest x ray, bronchoscope, PFT,
GIT study, sinus X ray or CT).
Results: An etiology of chronic

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 25 2024
Journal Name
Baghdad Science Journal
Hybrid Framework To Exclude Similar and Faulty Test Cases In Regression Testing
...Show More Authors

 

Regression testing is a crucial phase in the software development lifecycle that makes sure that new changes/updates in the software system don’t introduce defects or don’t affect adversely the existing functionalities. However, as the software systems grow in complexity, the number of test cases in regression suite can become large which results into more testing time and resource consumption. In addition, the presence of redundant and faulty test cases may affect the efficiency of the regression testing process. Therefore, this paper presents a new Hybrid Framework to Exclude Similar & Faulty Test Cases in Regression Testing (ETCPM) that utilizes automated code analysis techniques and historical test execution data to

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sat Jan 03 2026
Journal Name
Al–bahith Al–a'alami
Conflict and Integration between New and Traditional Media
...Show More Authors

The new media scene reveals that the unprecedented overlap of a number of technical, economic, and political factors has made the new media a very complicated issue; and the focus of specialized and public debates about its impact on traditional means of communication and forms of social media and social relations. Then, the same scene discloses the reality of the relationship between the new and the traditional. These are the axes that will be will be discussed in this study.

View Publication Preview PDF
Crossref