Oily wastewater is one of the most challenging streams to deal with especially if the oil exists in emulsified form. In this study, electrospinning method was used to prepare nanofiberous polyvinylidene fluoride (PVDF) membranes and study their performance in oil removal. Graphene particles were embedded in the electrospun PVDF membrane to enhance the efficiency of the membranes. The prepared membranes were characterized using a scanning electron microscopy (SEM) to verify the graphene stabilization on the surface of the membrane homogeneously; while FTIR was used to detect the functional groups on the membrane surface. The membrane wettability was assessed by measuring the contact angle. The PVDF and PVDF / Graphene membranes efficiency was tested in separation of emulsified oil from aqueous solutions. The results showed that PVDF-Graphene nanofiber membrane exhibited better performance than the plain PVDF nanofiber membrane with average water flux of 210 and 180 L.m-2.h-1, respectively. Both membranes showed high oil rejection with more than 98%.
Objectives: With the advent of ongoing novel modalities toward the treatment of human epidermal growth factor receptor 2 (HER2)/NEU - positive malignancies, the serious side effects of chemoradiotherapy have been minimized. Hence, this study was conducted to identify the patterns of immunohistochemical expression of the promising therapeutic target (HER2/NEU) among Iraqi patients with medulloblastoma in an attempt to provide basic histological information’s that would help in future clinical researches.Materials and Methods: In this retrospective study, 42 formalin - fixed paraffin - embedded tissue blocks represent cases of surgically removed medulloblastomas were retrieved from the archived materials in a specialized surgical ho
... Show MoreAn observational study to discover the common conditions affecting the lumbosacral region that may affect lumbosacral position and tension. All the patients, underwent MRI exaamination (magnetic resonance imaging) in the supine position, were examined by the same consultant radiologist. The article was revised by the institutional ethical approval committee. The position of the nerve roots was observed, and the number of nerve roots was calculated anterior to a line passing between the mid-transvers process of L3(third lumbar vertebra). The number of nerve roots ahead of this line was calculated by the radiologist at the level of the right intervertebral foramen and at the left one. This procedure was applied to the normal group, an
... Show MoreCongenital valvular pulmonary stenosis accounts for 5-10% of all congenital heart disease. Balloon pulmonary valvuloplasty is a safe and effective method in reduction of moderate to severe valvular pulmonary stenosis. This retrospective study done in Hawler surgical specialty cardiac center on pediatric patients who had pulmonary valve stenosis (with echocardiographic peak gradient 2:50mmHg) and treated by balloon pulmonary valvuloplasty. A total of 178 cases were involved, 93(52.25%) patient was male and 85 (47.75%) patients was female. 160 patient (89.89%) were treated with single balloon method 18 patient (10.11%) were managed by double balloon method technique. Follow up period of these patients range from 1 year to 10 years (mean of 5.
... Show MoreRetreatment Efficacy of Continuous Rotation Versus Reciprocation Kinematic Movements in Removing Gutta-Percha with Calcium Silicate-Based Sealer: SEM Study, Raghad Noori Nawaf*, Ra