Preferred Language
Articles
/
bsj-5067
Biochemical and Histological Study of Aminoacylase-1 Purified from Amniotic Fluid in Rats with Oxidative Stress Induced by Lead Acetate
...Show More Authors

This work involves separating and studying the aminoacylase-1 (ACY1) of amniotic fluid from healthy pregnant, mainly one peak with higher activity has been isolated by DEAE-Cellulose ion exchange from the proteinous supernatant produced by deposition of proteins using ammonium sulfate  (65%) after dialysis. The purification folds reaching to 19 folds also gave one protein peak when injected into the gel filtration column, a high ACY1 purity was obtained, with 38 folds of purification. It was found that the molecular weight of the isolated ACY1 was up to 46698 Dalton when using gel chromatography technique.The effect of ACY1 isolate was studied on rats with oxidative stress caused by lead acetate(LA) at 40 mg / kg body weight and compared with normal rats by measuring the selected biochemical parameters which included: Glutathione (GSH), malondialdehyde (MDA), aspartate aminotransferase (AST) and alanine aminotransferase (ALT) through liver and kidney tissue examination. The results showed a significant increase in the levels of (MDA, AST, ALT) and a decrease in the level of GSH compared with the control group, Also it has been observed there that was a significant decrease in the levels of (MDA, AST, ALT) and high level of GSH when injecting the ACY1 isolate in a dose of 4 mg / kg of rat weight with LA at 40 mg/kg. The results of the tissue examination demonstrated high pathological changes in the liver tissue of rats treated with LA at 40 mg/kg of rat weight when compared with normal rats. The liver and kidney tissue improved when treated with isolate at 4 mg / kg rat weight and LA. These results demonstrate the role of ACY1 in protecting from oxidative stress then can reduce the severity of various diseases.

Studying the effect of ACY1 isolated on rats with oxidative stress caused by lead acetate at a dose of 40 mg / kg body weight and compared with normal rats by measuring the selected biochemical parameters which included: Glutathione (GSH), malondialdehyde (MDA), aspartate aminotransferase (AST) and alanine aminotransferase (ALT) as well as through liver and kidney tissue examination. The results showed a significant increase in the levels of (MDA, AST, ALT) and a decrease in the level of GSH compared with the control group, It was also observed that there was a significant decrease in the levels (MDA, AST, ALT) and high level of GSH when using the enzyme isolated in a dose of 4 mg / kg of rat weight with lead acetate at a dose of 40 mg/kg. The results of the tissue examination showed high pathological changes in the liver tissue of rats treated with lead acetate at a dose of 40 mg/kg of rat weight when compared with normal rats, and liver and kidney tissue improvement when isolated enzyme is administered at 4 mg / kg rat weight with lead acetate. These results demonstrate the role of isolated enzyme in protecting the body from oxidative stress then can reducing the severity of various diseases.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance Study of Electrodialysis for Treatment Fuel Washing Wastewater
...Show More Authors

In this work, electrodialysis (ED) has been demonstrated to be appropriate technique for reducing the electrical conductivity of real wastewater from fuel washing unit, which has been previously treated by other electrochemical technology (electrocoagulation and electrooxidation).  A five cell electrodialysis stack, with an active membrane area of 60 cm2 per cell was employed. During a batch recirculation mode ED system, the effects of parameters such as electrical potential applied (6-18 V) and flow rate of streams (0.5-1.7 L/min.) on the performance of the total dissolved solids (TDS) separation and specific power consumption (SPC) were studied. The results indicate that the process of ED under potential (15 V) and flow

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
(?m 10.6) Design study for Reserve of laser CO2
...Show More Authors

In this paper , the CO2 laser receiver system is designed and studied, with wavelength laser 10.6 ?m in room temperature , and to evaluate the performance and discussion it via the package of optical design (ZEMAX), from its output the Spot Diagram is measured through RMS ,and from the Ray fan plot , the aberrations is found which is the normal error for the best focus named (under corrected ) , the other output was the Geometric Encircled Energy in the spot diagram . and found that the radius of spot diagram at 80% (R80%) from the total energy ,and focal shift .The designed system have high efficiency and low cost .

View Publication Preview PDF
Crossref
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
Experimental study of some shielding parameters for composite shields
...Show More Authors

View Publication
Scopus (10)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Wed Sep 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Study of Forward Osmosis Using Various Drawing Agent
...Show More Authors

This research was aimed to study the osmotic efficiency of the draw solutions and the factors affecting the performance of forward osmosis process : The draw solutions used were magnesium sulfate hydrate (MgSO4.7H2O) pojtassium chloride (KCL), calcium chloride (CaCl2) and ammonium bicarbonate (NH4HCO3). It was found that water flux increases with increasing draw solution concentration, and feed solution flow rate and decreases with increasing draw solution flow rate and feed solution concentration. And also found that the efficiency of the draw solutions is in the following order:

CaCl2> KCI > NH4HCO3> MgSO4.7H

... Show More
View Publication Preview PDF
Publication Date
Fri Nov 01 2013
Journal Name
Iraqi Journal Of Community Medicine
Clinico-Histopathological Study of Calcinosis Cutis among Iraqi Patients
...Show More Authors

AA Noaimi, IRAQI JOURNAL OF COMMUNITY MEDICINE, 2013 - Cited by 1

View Publication
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Economics And Administrative Sciences
Comparison of survival models to study determinants liver cancer
...Show More Authors

Cancer is one of the dangerous diseases that afflict a person through injury to cells and tissues in the body, where a person is vulnerable to infection in any age group, and it is not easy to control and multiply between cells and spread to the body. In spite of the great progress in medical studies interested in this aspect, the options for those with this disease are few and difficult, as they require significant financial costs for health services and for treatment that is difficult to provide.

This study dealt with the determinants of liver cancer by relying on the data of cancerous tumours taken from the Iraqi Center for Oncology in the Ministry of Health 2017. Survival analysis has been used as a m

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 02 2016
Journal Name
Iraq Nat J Chem
Adsorption study of drug cefixime onto surface Iraqi Attapulgite
...Show More Authors

Publication Date
Wed Sep 07 2016
Journal Name
Journal Of The Faculty Of Medicine
Non discogenic lumbar radiculopathy ((A study of 104 cases))
...Show More Authors

AW Ali T, Journal of the Faculty of Medicine, 2016 - Cited by 1

View Publication
Publication Date
Fri Feb 01 2019
Journal Name
Journal Of Physics: Conference Series
Study the Electrical Properties of Carbon Nanotubes/Polyaniline Nanocomposites
...Show More Authors

Several schottky diodes were fabricated from polyaniline/ Carbon nanotube (single and multiwalled) composites. These composites were synthesized with different concentration and two carbon nanotubes types, Single and Multi-Walled Carbon Nanotubes (SWCNT & MWCNT). Aluminum and silver paste were chosen as schottky and ohmic contact respectively. physical and electrical were used to studied these composite by using Atomic Force Microscopy (AFM) and electrical measurements. The Root Mean Square RMS surface roughness of the composite samples was found to be around 4nm. The currentvoltage characteristic were measurements for all samples in the bias range ±15V at room temperature. The results shows the increasing in carbon nanotubes concentration

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Mon Jan 07 2013
Journal Name
Nanoscience And Nanotechnology
Low Frequency Dielectric Study of PAPA-PVA-GR Nanocomposites
...Show More Authors

View Publication
Crossref (18)
Crossref