A simple, rapid, accurate and sensitive spectrophotometric method for the determination of thiaminehydrochloride has been developed. The method is based on the formation of the Schiff’s base between the primary amino group present in thiamine hydrochloride and aldehyde group present in the vanillin reagent to produce a yellow colored complex having maximum absorption at 390 nm. Beer’s law has obeaid over the concentration range of 2-28µg/mL, with molar absorptivity of 0.96x104L/mol.cm. The average recovery which is a measure of accuracy is 100±1.3% and the relative standard deviation (RSD) is less than1.5 .The present method is considered to be simple because it does not need heating, hydrolysis and solvent extraction steps. The ingredients often formulated with thiamine and have been shown not to interfere, and is suitable for the routine determination of thiamine hydrochloride. The proposed method has been successfully applied for the determination of thiamine hydrochloride in pure form and in pharmaceutical preparations.
Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) has caused enormous issues worldwide and is the most infectious pandemic. This study included 50 subjects (evenly distributed between sexes) and their range of ages starting from 2 to 67 years. According to the study's result, the ages and genders of subjects include susceptibility to COVID-19. Males were found to be more infected than females, and the ages of 36 to 67 were more common than other age ranges. Also, BMI calculations revealed that male patients with COVID-19 have the highest percentage of obesity. The clinical parameter results have been found serum C‐reactive protein (CRP) as an essential indicator that changes significantly in infection with COVID‐19 an
... Show MoreThe musical sign was associated with the first appearances of acting that are based on human gestures and expressive and silent movements, and they contributed in accentuating and clarifying these gestures and explain their meanings and indications, and they remained with them until these gestures turned into artistic theatrical shows so that the musical sign would have many functions and constitute the main pillars for this kind of show.
The musical sign is a language not much different than the human language in the semiotic analysis. There has been an increased interest in it and its use in the mime shows by the graduates who realized its necessity and significance in the pantomime show intellectually, artistically and aesthetical
0
Abstract
The research to have a clear perceptions about the knowledge value added to assess the knowledge resources of the Iraqi private banks, depending on the value added methodology of the proposed defined (Housel & Bell, 2001), which assumes that the knowledge value added come through synergetic relationship between knowledge resource and information technology, trying to the possibility of mainstream theory and its application in the Iraqi environment and interpretation of results, and on this basis was launched search of a research problem took root synergetic nature of the relationship between knowledge (human) resource and
... Show MoreCoherent density fluctuation model (CDFM) has been used to calculate the
proton momentum distributions (PMD) and elastic electron scattering form factors,
F(q), of the ground state for some even mass nuclei of fp-shell, such as 52Cr, 58Fe and
64Ni nuclei. Both of the PMD and F(q) have been expressed in terms of the weight
function ( ( ) )
2
f x which is determined by means of the charge density
distributions (CDD) of the nuclei and determined from theory and experiment. The
feature of the long-tail behavior at high momentum region of the PMD’s has been
obtained by both the theoretical and experimental weight functions. The calculated
form factors of these nuclei are in reasonable agreement with those of th
The calibration of the three meter Baghdad University Radio Telescope (BURT) has been performed using two types of calibrations: Antenna Position calibration, and Detector calibration. The sun is used as a reference source to calibrate the telescope. The antenna position Azimuth (Az), and Elevation (El) are calibrate according to sun's azimuth and elevation in the date (11/10/2017; at time 10:19 AM). A calibration report is designed to illustrate the calibration parameters for each specific date and time. The detector calibration is representing a study for power spectrum response for the sun according to radio telescope frequency band (1.3 GHz – 1.5 GHz) with central frequency (1.42 GHz). Drift Scan function in the telescope's softwar
... Show MoreUltrasonic pulse echo measurements on porous alumina as ceramic
material with porosities ranging from (20-40)% showed effect of volume
fraction of porosity on both thermal and elastic properties. A quadratic relationships, by using a least squares method, is deduced for the dependence of the shear velocity, longitudinal velocity, shear modulus, Young's modulus, bulk modulus, Poisson 's ratio, Debye temperature, specific heat, and thermal conductivity on the total porosity. By these relationships, the thermal and elastic properties results of pore-free alumina were calculated. The elastic properties results of
... Show More