Preferred Language
Articles
/
bsj-4494
Extraction, Purification and Characterization of Peroxidase from Pseudomonas aeruginosa and Utility as Antioxidant and Anticancer
...Show More Authors

        Peroxidase is a class of oxidation-reduction reaction enzyme that is useful for accelerating many oxidative reactions that protect cells from the harmful effects of free radicals. Peroxidase is found in many common sources like plants, animals and microbes and have extensive uses in numerous industries such as industrial, medical and food processing. In this study, P. aeruginosa was harvested to utilize and study its peroxidases. P. aeruginosa was isolated from a burn patient, and the isolate was verified as P. aeruginosa using staining techniques, biochemical assay, morphological, and a sensitivity test. The gram stain and biochemical test result show rod pink gram-negative bacteria, and ensure that the isolate was that of P. aeruginosa. Optimization for bacterial growth  were done by used more than pH (5,7,9) and temperatures (32,35,37°C), and it was found that the best growth conditions were at pH 5.5, producing (4.5x108cells), and a temperature of 37°C, with (5.25x108cells) being produced. Intracellular enzymes were extracted by ultra-sonication that used frequencies of ultrasound 30 kHz for 20 min in 4 °C, and was centrifuged at 13000×g for 5min. The supernatant was then re-used as a crude enzymatic extract and the cell pellet was discarded. Purification of peroxidase was accomplished by using salt precipitation, dialysis, gel filtrations and ion exchange chromatographic techniques. The result shows that gel filtration has optimal specific activity and purification fold at (61 U/ml), purification fold 6 times and then the improvement enzyme was applied as H2O2 scavenging activity antioxidant by used three concentration of enzyme (10,40,60 µg/ml), and show higher scavenging activity at 60 µg/ml, which reached to 45% scavenging activity. The enzyme was also used as anticancer agent, which was verified by using three concentration of enzyme (10,15,20 µg/ml) which show a significant kill for Mcf-7cells at (15µg/ml), with cytotoxicity activity reaching (45%).                        

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri May 01 2015
Journal Name
Transplantation Proceedings
Prevalence of Polyomavirus Among United Arab Emirates Kidney Transplant Recipients: Results From a Single Center
...Show More Authors

View Publication
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Mon Aug 15 2022
Journal Name
Revis Bionatura
ND2 Gene Sequencing of Sub fertile Patients Recovered from COVID-19 in Association with Toxoplasmosis
...Show More Authors

A total of (90) blood samples were collected from male patients infected with Toxoplasmosis who recovered from COVID- 19 and attended Kamal Alsamiraai Hospital from 15 January to 15 September 2021. We measured anti-Toxoplasma antibodies (IgG and IgM) detected by ELISA, whereas Anti-COVID-19 antibodies (IgG and IgM) were estimated using Elisa and Afilias. The semen characteristics were also studied among fertile, healthy individuals (control group) and sub-fertile patients. Results showed that the mean sperm count was high among the control group (40.5±1.3x 106/ml) compared with that of the sub-fertile patients (10.3±1.75 and 8.8±1.9 x 106/ml for oligozoospermia, and oligoasthenozoospermia respectively), and it was the highest (44.7±1.4

... Show More
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Removal Color Study of Toluidine Blue dye from Aqueous Solution by using Photo-Fenton Oxidation
...Show More Authors

The degradation of Toluidine Blue dye in aqueous solution under UV irradiation is investigated by using photo-Fenton oxidation (UV/H2O2/Fe+). The effect of initial dye concentration, initial ferrous ion concentration, pH, initial hydrogen peroxide dosage, and irradiation time are studied. It is found put that the removal rate increases as the initial concentration of H2O2 and ferrous ion increase to optimum value ,where in we get more than 99% removal efficiency of dye at pH = 4 when the [H2O2] = 500mg / L, [Fe + 2 = 150mg / L]. Complete degradation was achieved in the relatively short time of 75 minutes. Faster decolonization is achieved at low pH, with the optimal value at pH 4 .The concentrations of degradation dye are detected by spectr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 31 2022
Journal Name
Al-kindy College Medical Journal
Evaluation of Streptocin SH3, a Bacteriocin produced by Streptococcus sanguinis isolated from Human Dental Plaque
...Show More Authors

Background: Bacteriocin is a peptidic toxin has many advantages to bacteria in their ecological niche and has strong antibacterial activity. Objective: The aim of this study was to evaluation of bacteriocin using Streptococcus sanguinis isolated from human dental caries.

Subjects and Methods: Thirty five streptococcus isolates were diagnosed and tested for their production of bacteriocin, and then the optimal conditions for production of bacteriocin were determined.  After that, the purification of bacteriocin was made partially by ammonium sulfate at 95% saturation levels, followed by and gel filtration chromatography

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Aug 18 2023
Journal Name
Asia-pacific Journal Of Chemical Engineering
Facile preparation of dual functions zeolite‐carbon composite for zinc ion removal from aqueous solutions
...Show More Authors
Abstract<p>The cost‐effective dual functions zeolite‐carbon composite (DFZCC) was prepared using an eco‐friendly substrate prepared from bio‐waste and an organic adhesive at intermediate conditions. The green synthesis method used in this study ensures that chemically harmless compounds are used to obtain a homogeneous distribution of zeolite over porous carbon. The greenly prepared dual‐function composite was extensively characterized using Fourier transform infrared, X‐ray diffraction, thermogravimetric analysis, N<sub>2</sub> adsorption/desorption isotherms, field emission scanning electron microscope, dispersive analysis by X‐ray, and point of zero charges. DFZCC had a surface area o</p> ... Show More
View Publication
Scopus (33)
Crossref (26)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Alexandria Engineering Journal
Calcium/iron-layered double hydroxides-sodium alginate for removal of tetracycline antibiotic from aqueous solution
...Show More Authors

Crossref (46)
Crossref
Publication Date
Fri Nov 25 2022
Journal Name
Baghdad Science Journal
Evaluating the Activity of Ultrasound on Biofilm Formation by Acinetobacter baumannii isolated from clinical Specimens
...Show More Authors

Acinetobacter baumannii received attention for its multi-drug resistant associated with many severe infections and outbreaks in clinical environment. The aims of the study are to investigate the antibiotic susceptibility profile of clinically isolated A. baumannii, biofilm production, and the efficiency of Low Frequency Ultrasound (LFU) and honey to attenuate biofilm production. A total of 100 samples were taken from different sources from Baghdad hospitals. The susceptibility patterns revealed the percentage of pan drug resistant (PDR) isolates were 1.5 %, 72.7 % were extended drug resistant (XDR), 16.7 % were multidrug resistant (MDR), and 9.1 % were non MDR and sensitive to most antibiotics used. The ability to form

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (3)
Scopus Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Removal of COD from Petroleum refinery Wastewater by Electro-Coagulation Process Using SS/Al electrodes
...Show More Authors
Abstract<p>In the present study, the effectiveness of a procedure of electrocoagulation for removing chemical oxygen demand (COD) from the wastewater of petroleum refinery has been evaluated. Aluminum and stainless steel electrodes were used as a sacrificial anode and cathode respectively. The effect of current density (4-20mAcm<sup>−2</sup>), pH (3-11), and NaCl concentration (0-4g/l) on efficiency of removal of chemical oxygen demand was investigated. The results have shown that increasing of current density led to increase the efficiency of COD removal while increasing NaCl concentration resulted in decreasing of COD removal efficiency. Effect of pH was found to be lowering COD re</p> ... Show More
View Publication
Scopus (44)
Crossref (31)
Scopus Crossref
Publication Date
Wed Apr 01 2020
Journal Name
Malaysian Journal Of Biochemistry And Molecular Biology
Mutations in ergosterol 11 gene of fluconazol resistant candida albicans isolated from different clinical samples
...Show More Authors

Fluconazole was used to test the susceptibility of Candida albicans isolated from different clinical samples, and to detect mutations in ERG11 gene, and their relationship to fluconazole resistance. Forty-eight isolates of Candida albicans were tested for susceptibility using the disc diffusion method (M-44). ERG11 genes of six isolates were amplified (four resistant, two susceptible) and sequenced. The sequenced genes were analyzed to detect the mutations. Out of 48 isolates of Candida albicans, 4 (8%) were resistant to fluconazole. Sixteen-point mutations were detected included 13 silent mutations, and three missense mutations. The mutations of A945C (E266D) and G1609A (V488I) were found only in susceptible Candida albicans isolates, whil

... Show More
Preview PDF
Scopus (6)
Scopus
Publication Date
Sat Dec 01 2012
Journal Name
Journal Of Engineering
Effect of Oscillatory Motion in Enhancing the Natural Convection Heat Transfer from a Vertical Channel
...Show More Authors

This paper reports an experimental study regarding the influence of vertical oscillations on the natural convection heat transfer from a vertical channel. An experimental set-up was constructed and calibrated; the vertical channel was tested in atmosphere at 25o
C. The channel-to-ambient temperature difference was varied with the power supply to the electrical heater ranging between
15W to 70W divided into five levels. Data sets were measured under different operating condition from a test rig under six vibrating velocities (VVs) levels ranging from (5-30 m/s) in addition to the stationary state. The results show that the maximum heat transfer enhancement factor (E) occurs at Rayleigh number (Ra=2.328×103 ) and vibrational Reynol

... Show More
View Publication Preview PDF
Crossref