In the present work, the surface properties of mixed binary surfactants containing sodium dodecylbenzene sulfate (SDBS) and Tween 80 (TW80) surfactants in aqueous solutions were studied at temperature 293 K using surface tension measurements. The critical micelle concentration (cmc) magnitude for both individual surfactants and their mixtures were established the obtained results revealed that the magnitude of cmc of the mixtures are less than the magnitude of individual surfactants and decrease with the increase in Tween 80 percent in solution which indicate the nonideal mixing of the two surfactants. The values of molecular interaction parameters and the mole fraction of surfactants in the micelle (X1) were calculated on the basis of Rubingh’s model and showed that the interaction parameter is always negative but at 0.9 mole fraction of TW80 surfactant (α1) is positive
حظيت عدد من الشخصيات التاريخية ممن كان لها أثر واضح المعالم في تطور النظام الإداري والسياسي للإمبراطورية المغولية، بأهتمام عدد لا بأس به من الباحثين.
I
In this study, optical fibers were designed and implemented as a chemical sensor based on surface plasmon resonance (SPR) to estimate the age of the oil used in electrical transformers. The study depends on the refractive indices of the oil. The sensor was created by embedding the center portion of the optical fiber in a resin block, followed by polishing, and tapering to create the optical fiber sensor. The tapering time was 50 min. The multi-mode optical fiber was coated with 60 nm thickness gold metal. The deposition length was 4 cm. The sensor's resonance wavelength was 415 nm. The primary sensor parameters were calculated, including sensitivity (6.25), signal-to-noise ratio (2.38), figure of merit (4.88), and accuracy (3.2)
... Show MorePhotonic Crystal Fiber (PCF) based on the Surface Plasmon Resonance (SPR) effect has been proposed to detect polluted water samples. The sensing characteristics are illustrated using the finite element method. The right hole of the right side of PCF core has been coated with chemically stable gold material to achieve the practical sensing approach. The performance parameter of the proposed sensor is investigated in terms of wavelength sensitivity, amplitude sensitivity, sensor resolution, and linearity of the resonant wavelength with the variation of refractive index of analyte. In the sensing range of 1.33 to 1.3624, maximum sensitivities of 1360.2 nm ∕ RIU and 184 RIU−1 are achieved with the high sensor resolutions of 7
... Show MoreThis research includes an analytical and critique study for the version of the University Service Law No.23 for the year 2008, containing all its aspects and failure whether in its legislation or its applications.
The facilities layout are among the most important of the most influential factors in the efficiency of the production system, and represents the systematic layout of the various work centers, tools, persons, and other auxiliary services within the factory. Careful selection of the technique that would be used in Re-layout, represents an important step in reaching to the optimum layout that keeps on reducing handling costs and reduce unnecessary movement of materials, as well as the regularity and functioning of the flow of materials through the facilities. The research aims to propose a new layout of (Al-M'ammon Factory / The General Company for Vegetable Oils Industry), and then re-layout according to the new propose layout by using of te
... Show Moreيناقش البحث المقومات المادية والمجتمعية والموضوعية للدور الاقليمي العراقي بعد العام 2010 والفرص المتاحة والقيود التي تحد منه والافاق المستقبلية لهذا الدور في ظل بيئة اقليمية تسودها منظومات تحالف متناقضة في الاهداف والاستراتيجيات
This research work aims to the determination of molybdenum (VI) ion via the formation of peroxy molybdenum compounds which has red-brown colour with absorbance wave length at 455nm for the system of ammonia solution-hydrogen peroxide-molybdenum (VI) using a completely newly developed microphotometer based on the ON-Line measurement. Variation of responses expressed in millivolt. A correlation coefficient of 0.9925 for the range of 2.5-150 ?g.ml-1 with percentage linearity of 98.50%. A detection limit of 0.25 ?g.ml-1 was obtained. All physical and chemical variable were optimized interferences of cation and anion were studied classical method of measurement were done and compared well with newly on-line measurements. Application for the use
... Show More