The study was conducted for the detection of Aflatoxin B1(AFB1) in the serum and urine of 42 early and middle childhood patients (26 male and 16 female ) with renal function disease, liver function disease, in additional to atrophy in the growth and other symptoms depending on the information within consent obtained from each patient, in addition to 8 children, apparently healthy, as the control. The technique of HPLC was used for the detection of AFB1 from all samples. The results showed that out of 42 patient children, 19 (45.2%) gave positive detection of AFB1 in the serum among all age groups patients with a mean of 0.88 ng/ml and a range of (0.12-3.04) ng/ml. This was compared with the control that did not detect any level. On the other hand, AFB1 was not detected in any of urine samples in both of the sexes. Positive results of serum AFB1 were recorded in males more than females sample which reached 12(46.1%) and 7(43.7%) respectively with a mean/ range reached to (1.08 /0.12-2.91 and 0.82/0.12-1.30)ng/ml respectively, compared with 8 control samples that did not detect any value of aflatoxins.
This study investigated the shear performance of concrete beams with GFRP stirrups vs. traditional steel stirrups. Longitudinal glass fiber‐reinforced polymer (GFRP) bars were used to doubly reinforce the tested beams at both the top and bottom of their cross sections. To accomplish this, several stirrup spacings were provided. Eight beam specimens, measuring 300 × 250 × 2400 mm, were used in an experimental program to test under a two‐point concentrated load with an equal span‐to‐depth ratio until failure. Four beams in Group I have standard mild steel stirrups of 8 mm diameter, while four beams in Group II have GFRP stirrups with the same adopted diameter. The difference betwe
This study aimed to detect antibiotics in water, particulate, plant, and sediment in the Tigris River within Baghdad City, in addition to their spatiotemporal variations, and related physicochemical parameters. Five sites were selected in the river. Three target antibiotics (tetracycline, gentamycin, and ciprofloxacin) were detected in water, particulate, plant, and sediment of the river at all selected sites. The results clearly showed that the concentrations of target antibiotics were sediment > water > plant > particulate. Site 3 is considered as a risk site where high concentrations of all antibiotics during the wet and dry seasons wer
The research aimed to statement, which impact that the development of Iraqi auditing standards in the fight against corruption and to fulfill the reform requirements by conducting a comparative study analysis with a framework proposal to amend the Iraqi Audit directory number statement (6) issued by the Accounting and Auditing Standards Board of the Republic of Iraq dated 08/24/2002 on audit planning and supervision on the basis of the latest versions of international auditing standards in this regard.
The researchers concluded that there is a need to update the standards (evidence) audit accredited in the Republic of Iraq in accordance with international auditing standards to meet the requirements of the report of the external a
... Show MoreFrom different hospitals in Baghdad city, 25 clinical isolates of Proteus spp. were collected from different clinical samples, all isolates were identified as Proteus mirabilis by using bacteriological and biochemical assays in addition to Vitek-2 identification system. 15 (60%) isolates were identifying as Proteus mirabilis. The susceptibility of P. mirabilis isolates towards cefotaxime and ceftazidime was (66.6 %), (20%) consecutively; while extended spectrum β-lactamases producing P. mirabilis percentage was (30.7 %). Because blaVEB-1 was documented as an important indicator for increasing risk of extended spectrum beta ßlactamases producing P. mirabilis isolates that began to spread from many geographic area to Far east which inc
... Show MorePhotonic Crystal Fiber Interferometers (PCFIs) are widely used for sensing applications. This work presents the fabrication and the characterization of a relative humidity sensor based on a polymer-coated photonic crystal fiber that operates in a Mach- Zehnder Interferometer (MZI) transmission mode. The fabrication of the sensor involved splicing a short (1 cm) length of Photonic Crystal Fiber (PCF) between two single-mode fibers (SMF). It was then coated with a layer of agarose solution. Experimental results showed that a high humidity sensitivity of 29.37 pm/%RH was achieved within a measurement range of 27–95%RH. The sensor also showed good repeatability, small size, measurement accuracy and wide humidity range. The RH sensitivity o
... Show More