Preferred Language
Articles
/
bsj-4131
Geometry, and Normal Modes of Vibration (3N-6) for Di and Tetra-Rings Layer (6, 0) Linear (Zigzag) SWCNTs; A DFT Treatment
...Show More Authors

            Density Functional Theory (DFT) method of the type (B3LYP) and a Gaussian basis set (6-311G) were applied for calculating the vibration frequencies and absorption intensities for normal coordinates (3N-6) at the equilibrium geometry of the Di and Tetra-rings layer (6, 0) zigzag single wall carbon nanotubes (SWCNTs) by using Gaussian-09 program. Both were found to have the same symmetry of D6d point group with C--C bond alternation in all tube rings (for axial bonds, which are the vertical C--Ca bonds in rings layer and for circumferential bonds C—Cc in the outer and mid rings bonds). Assignments of the modes of vibration IR active and inactive vibration frequencies (symmetric and asymmetric modes) based on the image modes applied by the Gaussian 09 display. The whole relations for the vibration modes were also done including nCH stretching, nC--C stretching, δCH, δring (δC--C--C) deformation in plane of the molecule) and gCH, gring (gC--C--C) deformation out of plane of the molecule. The assignment also included modes of puckering, breathing and clock-anticlockwise bending vibrations.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
Assessment of Radiological Air Contamination for Selected Places at Al-Tuwaitha Nuclear Site during Winter and Spring
...Show More Authors

This study presents the results of atmospheric particulates sampling using high volume air sampler for selected places at Al Tuwaitha nuclear site. The collected samples were analyzed for gross alpha /beta radioactivity using Ludlum model 3030 and measurement particles activity in Al Tuwaitha nuclear site and the surrounding areas for the period from 28/12/2016 to 13/4/2017.The measurement of activity concentrations ranged from (0.42±0.03 to 4.18±0.13) Bq/m3 for alpha particles and from(0.93±0.06 to 9.21±0.26) Bq/m3for beta particles. The activity concentration of nuclides inversely proportional with air temperature and wind speed while humidity is directly proportional with it. Highest value of activity concentration has been found at(

... Show More
View Publication Preview PDF
Scopus (7)
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
High performance liquid chromatographic method for the determination of guaifenesin in pharmaceutical syrups and in environmental samples
...Show More Authors

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml res

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Iraqi Journal Of Applied Physics
Structural and Morphological Characteristics of PEKK-Coated Titanium Disks by RF Magnetron Sputtering for Implant Osteointegration Application
...Show More Authors

Pure grade II titanium disks were coated with a thin coating of polyetherketoneketone (PEKK) polymer by RF magnetron sputtering using either nitrogen or argon gas. Sputtering technique was employed at 50 W for one hour at 60°C with continuous flow of nitrogen or argon gas. Field-emission scanning electron microscopy (FE-SEM) showed a continuous, homogeneous, rough PEKK surface coating without cracks. In addition, cross-sectional FE-SEM revealed an average coat thickness of 1.86 μm with argon gas and 1.96 μm with nitrogen gas. There was homogenous adhesion between the coating layer and substrate. The elemental analysis of titanium substrate revealed the presence of carbon, titanium, and oxygen. The RF magnetron sputtering with argon or ni

... Show More
Preview PDF
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Synthesis of 5-Fluorouracil Derivatives as Possible Mutual Prodrugs with Meloxicam and Ibuprofen for Targeting Cancer Tissues
...Show More Authors

In the present study, five derivatives have been designed to be synthesized as possible mutual prodrugs for 5-Fluorouracil (5-FU) and non steroidal anti-inflammatory drugs (NSAIDs) to selectively deliver the drugs into the cancer cells. The synthesis of the target compounds were accomplished following multistep reaction procedures, the chemical reaction followed up and the purity of the products were checked by TLC. The structure of the final compounds and their intermediates were confirmed by their melting points, infrared spectroscopy and elemental microanalysis, the hydrolysis of compound III was studied using HPLC technique. According to the results mentioned above, compounds (I−V) can be good candidates as possible mutual prod

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jan 30 2019
Journal Name
Modern Sport
Evaluation of training programs according to some physical abilities, functional indicators and achievement for men's 200m runners
...Show More Authors

The effectiveness of (200 m) of the events of extreme intensity and this is characterized by training in the anaerobic energy system prevailing in the result of this privacy as these are based on the physical abilities and functional indicators identified in this direction and hence the importance of research in the evaluation of training programs on the basis of physical abilities and some indicators of the functionality of the hostile 200 m . The study aimed to: 1. Evaluation of training programs according to physical abilities and some functional indicators of hostile men.The researchers used the descriptive analytical method to suit the nature of the research. The researchers selected them research sample by the deliberate method of the

... Show More
Publication Date
Wed Mar 04 2020
Journal Name
International Journal Of Psychosocial Rehabilitation
The Effect of Using Fit Light Exercise in Some Physiological Indicators and Smash Shot for Badminton’s Players
...Show More Authors

The reason for applying the project is for the development of some physiological variables and skill performance using a device for the first time applied in Iraq to a sample of badminton players, and this device has a patent on 7/2/2019. An experimental method is used for a sample of (12) players from (Al-Orthodoxy club). The experimental group is applied the proposal technique, while, the control group is instructed by the coach.The results of the research attribute to the role of the proposal exercises of fit light technology, thus, this technology has increased the attention and focusing of the sample and some physiological variables and smash shot skill. It has been concluded that the exercises using fit light technology is helped to i

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 23 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Flow Injection Spectrophotometric Technique for Determining of Genistein in Pure and Supplements Formulations Through Diazotization Coupling Reaction
...Show More Authors

Genistein (GEN) is The major isoflavone found in soybeans, has a number of cardiovascular health benefits, Postmenopausal syndrome and osteoporosis. A direct flow injection analysis method for estimation of (GEN) in pure and supplements formulation . This system is based on diazotization coupling reactions between procaine penciline (PR) and genistein in basic medium, they formed yellow dyes have maximum absorption at 416 nm. Calibration curve were constructed over different GEN concentrations, linearity for GEN was 10-100 µg.mL-1 and detection limits of 1.51 ?g/mL. In the FIA technique, all analytical factors were analyzed and optimized. The established method was successfully used to determine GEN in the formulations of its supplement

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Petroleum And Coal
Evaluation of geomechanical properties for tight reservoir using uniaxial compressive test, ultrasonic test, and well logs data
...Show More Authors

Scopus (9)
Scopus
Publication Date
Thu Sep 01 2022
Journal Name
Journal Of Engineering
Design and Implementation of Active Noise Cancellation for Car Cabin on Sulaimania Roads Using Arduino Embedded System
...Show More Authors

Car drivers hear many kinds of noise inside their vehicles' cabins, and the most annoying ones are the noise generated by tires, engines, and outside winds. Noise affects the comfort of the passengers inside the cabin, and it’s sad to say that modern cars are noisier in many kinds of noise signals due to using a lot of plastic materials in new budget cars. For expensive and luxury cars, the problem is solved by using better sound insulation materials, but for the budget ones, the approach used here is effective. It is called Active Noise Cancellation and can be done using analog or digital electronics. An operational amplifier and filters are used for the analog one, and in the digital one, signal processor chips are used. In engineeri

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Apr 01 2024
Journal Name
Baghdad Science Journal
Simultaneous spectrophotometric method for determination of both ciprofloxacin and cephalexin by using H-point standard addition method
...Show More Authors

طريقة سهلة وبسيطة ودقيقة لتقدير السبروفلوكساسين  في وجود السيفاليكسين او العكس بالعكس في خليط منهما. طبقت الطريقة المقترحة بطريقة الاضافة القياسية لنقطة بنجاح في تقدير السبروفلوكساسين بوجود السيفاليكسين كمتداخل عند الاطوال الموجية 240-272.3 نانوميتر وبتراكيز مختلفة من  السبروفلوكساسين 4-18 مايكروغرام . مل-1 وكذلك تقدير السيفاليكسين بوجود السبروفلوكساسين الذي يتداخل باطوال موجية 262-285.7 نانوميتر وبتراكيز مخ

... Show More
View Publication
Scopus (5)
Crossref (1)
Scopus Clarivate Crossref