The current study deals with the performance of constructed wetland (CW) incorporating a microbial fuel cell (MFC) for wastewater treatment and electricity generation. The whole unit is referred to as CW-MFC. This technique involves two treatments; the first is an aerobic treatment which occurs in the upper layer of the system (cathode section) and the second is anaerobic biological treatment in the lower layer of the system (anode section). Two types of electrode material were tested; stainless steel and graphite. Three configurations for electrodes arrangement CW-MFC were used. In the first unit of CW-MFC, the anode was graphite plate (GPa) and cathode was also graphite plate (GPc), in the second CW-MFC unit, the anode was stainless steel mesh (SSMa) and the cathode was a couple of stainless steel plain (SSPc). The anode in the third CW-MFC unit was stainless steel mesh (SSMa) and the cathode was graphite plate (GPc). It was found that the maximum performance for electricity generation (9 mW/m3) was obtained in the unit with stainless steel mesh as anode and graphite plate as cathode. After 10 days of operation, the best result for COD removal (70%) was obtained in the unit with stainless steel mesh as anode and stainless steel plain as cathode. The effect of temperature was also investigated. The performance of unit operation for electricity generation was tested at three values of temperature; 30, 35 and 40oC. The best result was obtained at 40oC, at which the current density obtained was 80 mA/m3. A culture of Algae could grow in the unit in order to supply the cathodic region with oxygen.
This study is the first investigation in Iraq dealing with genotyping of
Epstein-Barr Virus (EBV) infection is associated with broad spectrum of clinical manifestationsdepending on the immune status of the host, To analyze their possible role in the complication ofautoimmune hepatitis, we investigated (30) female patients with autoimmune hepatitis type-1 of(10-40)years and 25 healthy female of same ages(control groups). Both groups were carried outto measure the levels of EBV-CA IgM, IgG Ab, EBV-EA IgM, IgG Ab, and EBV-NA IgM, IgGAb using indirect immunoflourescent assay (IFAT).The prevalence of EBV-CA IgM, IgG Ab were(10%,20%) and EBV-EA IgM, IgG Ab were (10% and20%) respectively, while the prevalence ofEBV-NA IgG Ab was( 3.33%) and there are no prevalence of EBV-NA IgM Ab. There weresignificant differences (P
... Show MoreKurdistan power system is expanded along years ago. The electrical power is transmitted through long transmission lines. The main problem of transmission lines is active and reactive power losses. It is important to solve this issue, unless, the most of electrical energy will lost over transmission system. In this study, High Voltage Direct Current links/bipolar connection were connected in a power system to reduce the power losses. The 132kV, 50 Hz, 36 buses Kurdistan power system is used as a study case. The load flow analysis was implemented by using ETAP.16 program in which Newton-Raphson method for three cases. The results show that the losses are reduced after inserted HVDC links.
Background: Polycystic ovarian syndrome is one of the common gynaecological diseases encountered nowadays in the gynaecological clinic. Many criteria and diagnostic test had been evolved to be used with different classifications methods.Objectives: The present study aimed to measure the anti-mullerian hormone levels in serum of the women with Polycystic Ovary Syndrome and to test the possibility that if it can be used as a marker for diagnosis of polycystic ovary syndrome patients.Methods: A cross sectional study that had been conductedat Kamal AL-Samaraee Hospital, AL-Suwayrah Hospital andAl-Elwiya Maternity Teaching Hospital during the periodfrom July, 1st, 2013 – Jan. 1st, 2014. Where forty women withPolycystic ovarian syndrome (wit
... Show MoreFiber Reinforced Polymer (FRP) bars are anisotropic in nature and have high tensile strength in the fiber direction. The use of High-Strength Concrete (HSC) allows for better use of the high-strength properties of FRP bars. The mechanical properties of FRP bars can yield to large crack widths and deflections. As a result, the design of concrete elements reinforced with FRP materials is often governed by the Serviceability Limit States (SLS). This study investigates the short-term serviceability behavior of FRP RC I-beams. Eight RC I-beams reinforced with carbon-FRP (CFRP) and four steel RC I-beams, for comparison purposes, were tested under two-point loading.
Deformations on the concrete and crack widths and spacing are measured and
larization modulation plays an important role in polarization encoding in quantum key distribution. By using polarization modulation, quantum key distribution systems become more compact and more vulnerable as one laser source is used instead of using multiple laser sources that may cause side-channel attacks. Metasurfaces with their exceptional optical properties have led to the development of versatile ultrathin optical devices. They are made up of planar arrays of resonant or nearly resonant subwavelength pieces and provide complete control over reflected and transmitted electromagnetic waves opening several possibilities for the development of innovative optical components. In this work, the Si nanowire metasurface
... Show More